Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Trauma und Berufskrankheit 1 (1999), S. 392-397 
    ISSN: 1436-6274
    Keywords: Schlüsselwörter Distale Femurfraktur ; Minimalinvasive Therapie ; LISS ; Ergebnisse ; Key words Distal femur fracture ; Minimally invasive therapy ; LISS ; Results
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: In a prospective, nonrandomized study conducted between February 1997 and September 1998, 29 displaced fractures of the distal femur were stabilized with an angularly stable interlocking plate system (less invasive stabilization system, or LISS) designed for minimally invasive placement. The LISS System consists of an anatomically configured plate contoured to fit percutaneously onto the lateral femoral condyles with monocortical screws which anchor into the plate , thus building an angularly stable construct. Using the AO fracture classification system, 33 group C3 fractures and 32 C2 fractures with intra-articular displacement were fixated via a transarticular approach with a lateral parapatellar arthrotomy of the knee joint and percutaneous placement of the shaft screws, while 33 group A fractures and 32 C2 and B1 fractures with no intra-articular dislocation were treated via a lateral stab incision and placement of the LISS laterally on the femoral shaft under the vastus lateralis muscle. Twenty-nine fracture cases were included in the follow-up studies. The average patient age was 54 years (range 20–92) and mean duration of follow-up was 6 months (range 1.5–16). The mean injury severity score (ISS) was 14.1 (range 9–27). Twenty-six fractures were located at the distal segment of the femur (localization 33) and further subdivided into 13 group C3, four group C2, eight type A fractures, and one type B fracture. An additional three fractures were located at the distal shaft (localization 32) and classified as subgroup B1.3. Eight fractures were open (5 type I, 2 type II, 1 type IIIB3). Mean operative time was 131 minutes (range 40–¶300). Mean image intensifier time was 142 seconds (range 31–402). Postoperative complications included one case with heterotopic ossification (HO) limiting knee motion, one of deep venal thrombosis with pulmonary embolism, and three cases of deep infection (one type IIIB open, one arterial injury, and one type II open). Implant-related complications included two cases of screw pullout in the proximal plate during the first 2 months postinjury. These cases were treated by screw exchange. In a 37-year-old female with an increased antetorsion angle of 32° (internal rotation deformity) in both femurs postoperatively, rotational correction was performed. Length of time to fracture healing averaged 3.1 months (range 2.5–4.5) in 23 cases. Length of time to full weight-bearing averaged 3 months (range 1.5–5). At the latest review of 15 cases with an average of 3 months’ follow-up, knee flexion averaged 121° (min. 20°, max. 140°). Thirteen cases displayed knee flexion of less than 120°, three of which had less than 90°. At follow-up, an extension lag of 10° was noted in two cases. The Lysholm score could be applied to nine patients and showed a mean of 67.5 points (range 48–92), and the Neer scores averaged 69.8 points (range 49–88) (one failure, three unsatisfactory, four satisfactory, and one excellent). The remaining cases were still undergoing follow-up evaluation at the time of writing. The correct use of LISS for distal femoral fractures leads to uneventful bony healing without the additional morbidity of bone grafts. However, due to demanding surgical technique in this region, special care must be taken to restore correct axial alignment.
    Notes: In einer prospektiven, nicht randomisierten Studie wurden zwischen Februar 1997 und September 1998 29 frische distale Femurfrakturen mit dem winkelstabilen, minimalinvasiv eingebrachten System LISS (less invasive stabilization system) versorgt. Das Prinzip des LISS ist ein perkutan eingebrachtes Implantat, das anatomisch nach dem rechten und linken lateralen Femurkondylus geformt ist. LISS wird mit winkelstabilen, monokortikalen Schrauben verankert. In dieser Studie wurden 33C3- und 33C2-Frakturen mit intraartikulärer Dislokation über einen transartikulären Zugang mit lateraler parapatellarer Arthrotomie versorgt, während bei den 33A-Frakturen, 33C2- und 32B1-Frakturen ohne intraartikuläre Dislokation ein lateraler Zugang gewählt wurde. In die Nachuntersuchung wurden 29 Frakturen eingeschlossen. Das Durchschnittsalter der Patienten war 54 Jahre (20–92 Jahre). Die durchschnittliche Nachuntersuchungszeit betrug 6 Monate (1,5–16 Monate) und der durchschnittliche ISS 14,1 (9–27). Offen waren 8 Frakturen (5mal Typ I, 2mal Typ II, 1mal Typ IIIB nach Gustilo). Die durchschnittliche Operationszeit lag bei 131 min (40–300 min). Die durchschnittliche Bildwandlerzeit betrug 142 s (31–402 s). Postoperativ kam es in 1 Fall zu heterotopen Ossifikationen mit Einschränkung der Kniegelenkbeweglichkeit, in 1 Fall zu einer tiefen Beinvenenthrombose mit Lungenembolie und in 3 Fällen zu tiefen Infekten, davon 2mal als Folge offener Frakturen. In 2 Fällen kam es zu Schraubenausrissen im proximalen Plattenbereich innerhalb der ersten 2 Monate. In 1 Fall war eine Rotationsdifferenz beider Femora von 32° zu sehen. Die Zeit bis zur knöchernen Durchbauung betrug durchschnittlich 3,1 Monate (2,5–4,5 Monate), die Zeit bis zur Vollbelastung 3 Monate (1,5–5 Monate). Die Kniegelenkbeweglichkeit war in 15 Fällen, mit einer Nachuntersuchungszeit von mehr als 3 Monaten, 121° (Minimum 20°, Maximum 140°). Der Lysholm-Score konnte für 9 Patienten ermittelt werden und ergab im Durchschnitt 67,5 Punkte (48–92 Punkte), der Neer-Score 69,8 Punkte (49–88 Punkte). Die Anwendung des LISS ermöglicht eine komplikationslose Ausheilung ohne Notwendigkeit der Knochentransplantation. Besonderes Augenmerk muß auf eine achsengerechte Reposition gelegt werden, da diese am distalen Femur schwierig ist.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1434-601X
    Keywords: PACS:25.75.-q – 25.70.Mn – 21.10.Ft – 21.10.Gv – 27.50.+e – 27.50.+j – 24.10.Pa
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract: Projectile fragmentation of 238U in a lead target was investigated at a bombarding energy of 750 A MeV. Isotopic production cross sections of about 250 different projectile fragments in the element range Z= 30–53 were measured with the FRagment Separator (FRS). The magnetic selection and the kinematical analysis of the measured isotopes allowed to disentangle fission and fragmentation residues. The mass loss of these residues indicates a violent collision where a large amount of energy is dissipated. The position of the fragmentation corridor defined by the measured residues was used to determine an effective proton-evaporation barrier.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1434-601X
    Keywords: PACS:25.85.-w Fission reactions – 25.75.-q Relativistic heavy-ion collosions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract: Fragments of relativistic 750 A.MeV U-projectiles were investigated by using the fragment separator FRS for magnetic selection of reaction products including ray-tracing and ΔE-ToF techniques. For elements between Ge and Sb, measurements of isotopic yield distributions and velocities revealed three processes: fragmentation, low-energy fission, and high-energy fission. The last of these regimes is presently reported. First and second moments of distributions of mass numbers, atomic numbers and velocities of the corresponding fragments allowed us to identify 101 43Tc56 as the most probable fragment of a high energy symmetric fission reaction. Moreover, we could deduce a hypothetical mean fissioning fragmentation product 208Rn and its highly excited pre-fragmentation parent 227Ra produced in a primary abrasion reaction at an excitation energy of about 290 MeV.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1434-601X
    Keywords: 21.60.C5 ; 27.50+e ; 25.85-w
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We report the first observation of the doubly magic nucleus78Ni50 and the heavy isotopes77Ni,73,74,75Co,80Cu. The isotopes were produced by nuclear fission in collisions of 750 A·MeV projectiles of238U on Be target nuclei. The fully-stripped fission products were separated in-flight by the fragment separator FRS and identified event-by-event by measuring the magnetic rigidity, the trajectory, the energy deposit, and the time of flight. Production cross-sections and fission yields for the new Ni-isotopes are given.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1434-601X
    Keywords: PACS:25.85.-W Fission reactions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract: Projectile fission of 750 AMeV 238U-ions interacting with a Pb target was studied by means of the spectrometer FRS, GSI-Darmstadt. One of the two fission fragments was detected with a transmission of few percent and identified in mass and charge. Low-energy fission (E* 〈 25 MeV) events were selected by their magnetic rigidity. Whereas the production of asymmetric fission events is dominated by the GDR excitation, very asymmetric fission and symmetric fission take place after a GQR or DGDR excitation or after a nuclear interaction. Cross sections of more than 250 isotopes were measured. Isotopic distributions of low-energy fission were reconstructed for elements from Se to Te. The fission modes SI, SII and SL were clearly shown in these distributions and in the mass and TKE distributions. Charge polarization and mass dispersion were deduced for each fission mode. Finally, the characteristics of the low-energy fission process explain the production rates of neutron-rich species.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1573-5079
    Keywords: energy transfer ; reaction center ; FMO-protein ; green sulfur bacterium (Chlorobium tepidum, Prosthecochloris aestuarii)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract The Fenna-Matthews-Olson (FMO)-protein and the FMO-reaction center (RC) core complex from the green sulfur bacterium Chlorobium tepidum were examined at 6 K by absorption and fluorescence spectroscopy. The absorption spectrum of the RC core complex was obtained by a subtraction method and found to have fiye peaks in the QY region, at 797, 808, 818, 834 and 837 nm. The efficiency of energy transfer from carotenoid to bacteriochlorophyll a in the RC core complex was 23% at 6 K, and from the FMO-protein to the core it was 35%. Energy transfer from the FMO-protein to the core complex was also measured in isolated membranes of Prosthecochloris aestuarii from the action spectra of charge separation. Again, a low efficiency of energy transfer was obtained, both at 6 K and at room temperature.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0044-8249
    Keywords: Diazoalkane ; Katalyse ; Metathese ; Polymerisationen ; Rutheniumverbindungen ; Chemistry ; General Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0570-0833
    Keywords: diazoalkanes ; catalysis ; metathesis ; polymerizations ; ruthenium compounds ; Chemistry ; General Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...