Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    ISSN: 1460-9592
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: The case series consisted of ten children, ranged in age from one to three years (median 1.8 yrs), and in body weight from 10.2 to 13.5 kg (median 11.7 kg), in ASA class 1 or 2, all without lung disease. Having undergone general anaesthesia for cranial or abdominal CT scans, the patients were studied for pulmonary morphology. The first pulmonary CT scan was taken five min after induction of general inhalational anaesthesia; preoxygenation was avoided and an intraoperative FiO2≤0.4 was used. Densities in dependent regions of both lungs were observed in all children. After ventilation with PEEP of 5 cmH2O, all the observed densities disappeared without impairment of heart rate, blood pressure, haemoglobin saturation and endtidal CO2 (PECO2). We conclude that the appearance in children of atelectasis cannot be explained by a reabsorption of O2 mechanism and by denitrogenation. However, a PEEP of 5 cmH2O is able both to recruit all the available alveolar units, and to induce the disappearance of atelectasis in dependent lung regions.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Publishing Ltd
    Anaesthesia 51 (1996), S. 0 
    ISSN: 1365-2044
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Publishing Ltd
    Anaesthesia 44 (1989), S. 0 
    ISSN: 1365-2044
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: This study measures the resistance to gas flow of different double-lumen bronchial tubes used for separate ventilation of each lung in critically ill patients. Different-sized Robertshaw and Carlens' tubes were studied, as well as a new device that consisted of a cuffed bronchial catheter introduced through a standard tracheal tube. The pressure-flow relationship was curvilinear in all cases. Robertshaw and Carlens' tubes were generally found to have bronchial and tracheal channels with almost similar resistance and offered total resistances similar to those of 7.0–8.0 mm internal diameter tracheal tubes. The new device had a higher resistance than others of equal external diameter. This must be taken into account when its use is recommended for prolonged respiratory support.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    ISSN: 1432-1238
    Schlagwort(e): Respiratory mechanics ; Weaning prediction ; COPD
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Objective To assess in a group of COPD patients mechanically ventilated for an episode of acute respiratory failure the respiratory mechanics with a simple and non invasive method at the bedside in order to evaluate if these parameters may be predictive of weaning failure or success. Design A prospective study. Setting Intensive care and intermediate intensive care units. Patients 23 COPD patients ventilated for acute respiratory failure and studied within 24 hours from intubation. Methods Using end-expiratory and end-inspiratory airway occlusion technique, we measured PEEPi, static compliance of the respiratory system (Crs, st) maximum respiratory resistance (Rrsmax) and minimum respiratory resistance (Rrsmin). Measurements and results The weaned group (A) and the not weaned group (B) were not different regarding to static PEEPi (group A 8.5±4.0 vs group B 8.9±2.6 cmH2O), to Rrsmax (22.4±5.3 versus 22.2±9.0 cmH2O/l/s) and to Rrsmin (17.6±5.5 versus 17.9±8.0 cmH2O/l/s), while a significant difference (p〈0.001) has been found in Cst, rs (62.7±17.5 versus 111.6±18.0 ml/cm H2O). The threshold value of 88.5 ml/cmH2O was identified by discriminant analysis and provided the best separation between the two groups, with a sensitivity of 0.85 and a specificity of 0.87. Conclusion Cst, rs measured non invasively in the first 24 h from intubation, provided a good separation between the patients who were successfully weaned and those who failed.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    ISSN: 1432-1238
    Schlagwort(e): Respiratory mechanics ; Respiratory resistance ; Respiratory compliance ; Mechanical ventilation ; Pressure support ventilation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Objective To evaluate a least squares fitting technique for the purpose of measuring total respiratory compliance (Crs) and resistance (Rrs) in patients submitted to partial ventilatory support, without the need for esophageal pressure measurement. Design Prospective, randomized study. Setting A general ICU of a University Hospital. Patients 11 patients in acute respiratory failure, intubated and assisted by pressure support ventilation (PSV). Interventions Patients were ventilated at 4 different levels of pressure support. At the end of the study, they were paralyzed for diagnostic reasons and submitted to volume controlled ventilation (CMV). Measurements and results A least squares fitting (LSF) method was applied to measure Crs and Rrs at different levels of pressure support as well as in CMV. Crs and Rrs calculated by the LSF method were compared to reference values which were obtained in PSV by measurement of esophageal pressure, and in CMV by the application of the constant flow, end-inspiratory occlusion method. Inspiratory activity was measured by P0.1. In CMV, Crs and Rrs measured by the LSF method are close to quasistatic compliance (−1.5±1.5 ml/cmH2O) and to the mean value of minimum and maximum end-inspiratory resistance (+0.9±2.5 cmH2O/(l/s)). Applied during PSV, the LSF method leads to gross underestimation of Rrs (−10.4±2.3 cmH2O/(l/s)) and overestimation of Crs (+35.2±33 ml/cmH2O) whenever the set pressure support level is low and the activity of the respiratory muscles is high (P0.1 was 4.6±3.1 cmH2O). However, satisfactory estimations of Crs and Rrs by the LSF method were obtained at increased pressure support levels, resulting in a mean error of −0.4±6 ml/cmH2O and −2.8±1.5 cmH2O/(l/s), respectively. This condition was coincident with a P0.1 of 1.6±0.7 cmH2O. Conclusion The LSF method allows non-invasive evaluation of respiratory mechanics during PSV, provided that a near-relaxation condition is obtained by means of an adequately increased pressure support level. The measurement of P0.1 may be helpful for titrating the pressure support in order to obtain the condition of near-relaxation.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Springer
    Intensive care medicine 11 (1985), S. 85-89 
    ISSN: 1432-1238
    Schlagwort(e): CPAP ; Airway pressure ; Rebreathing
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Continuous positive airway pressure is widely used in the treatment of ARF and an evaluation of the systems is important. The authors used an artificial model to test a continuous flow system with a high compliance reservoir bag. The results confirm that the system is effective in maintaining positive pressure stability within a wide range of inspiratory peak flow rates, even when a low fresh gas flow rate is employed. Nevertheless, rebreathing of expired gases is possible and may be noticeable at high expiratory flow rates, caused by the high compliance of the reservoir bag.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    ISSN: 1432-1238
    Schlagwort(e): Body iron pattern ; Serum ferritin ; Acute-phase protein ; Critically ill patients
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Serial measurements of blood haemoglobin, serum iron, serum transferrin, total iron-binding capacity, transferrin per cent saturation and serum ferritin were determined in 51 post-operative critically ill patients to investigate body iron status in severely stressed patients. The results showed decreased blood haemoglobin, serum iron, serum transferrin and transferrin saturation compared to an increase in serum ferritin levels. These results indicate that there is inadequate availability of iron to tissues (secondary to rearrangement of body iron to the advantage of the iron storage compartment), which is often present in severely critically ill patients. A positive correlation was found between the initial (ferritin) levels and SAPS (r=0.41,p〈 0.01). In addition, the increase of ferritin concentration parallels a worsening of the clinical status in severely ill patients. This is due to enhanced release by the macrophage system. From this, we consider serum ferritin as an acute-phase protein and a useful marker of the severity of the clinical status. It appears to be useful in predicting the patient's outcome, but is not reliable in evaluating iron stores in stressed patients.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    Springer
    Intensive care medicine 15 (1989), S. 488-490 
    ISSN: 1432-1238
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    Springer
    Intensive care medicine 22 (1996), S. 1131-1132 
    ISSN: 1432-1238
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    ISSN: 1432-1238
    Schlagwort(e): Key words Respiration ; artificial instrumentation ; Heat and moisture exchanger ; Respiratory mechanics ; Pressure support ventilation ; P0.1 ; Feedback control
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Objective: To investigate the mechanical effects of artificial noses. Setting: A general intensive care unit of a university hospital. Patients: 10 patients in pressure support ventilation for acute respir
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...