Library

Language
Preferred search index
Number of Hits per Page
Default Sort Criterion
Default Sort Ordering
Size of Search History
Default Email Address
Default Export Format
Default Export Encoding
Facet list arrangement
Maximum number of values per filter
Auto Completion
Feed Format
Maximum Number of Items per Feed
feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Electronic Resource  (1)
  • 1965-1969  (1)
Material
  • Electronic Resource  (1)
Years
Year
  • 1
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Flüssigkeits-Szintillationszählung zur Bestimmung von14C-markiertem Ametryn in Dünnschichtchromatogrammen wurde eingehend geprüft. Alterung, Löschungseffekt von Trägersubstanz und Adsorptionsmitteln, Temperaturbeständigkeit der Verbindung in adsorbiertem Zustand wurden untersucht. Die Reproduzierbarkeit beträgt 1 bis 2%, die Nachweisgrenze 0,005μg pro Tüpfel, das Signal-Hintergrund-Verhältnis 3∶1. Zur Lokalisierung der Flecken wurde die Fluoreszenzlöschung herangezogen. Die Ausbeute nach 30 Minuten Entwicklung auf Silikagelplatten war ungefähr 90% Ametryn, unabhängig vom Laufmittel. Bei zweidimensionaler Arbeitsweise wurden 75% wiedergefunden. Die Ausbeute aus Wasser- und Bodenproben lag zwischen 78 und 88%.
    Notes: Summary The use of the liquid scintillation counting method for the determination of14C labelled ametryne on thin-layer chromatograms has been thoroughly investigated. Aging, quenching effect of carrier and adsorbents as well as temperature stability of the compound in the adsorbed state have been studied. The method has a reproducibility of 1 to 2% and a detection limit of 0.005μg per spot at a 3 ∶ 1 signal to background ratio. Fluorescence quenching was used for the location of spots on the chromatogram. Recovery studies were carried out by this method. After 30 minutes development on a chromatoplate coated with silicagel, about 90% of the ametryne was recovered independent of solvent system used. About 75% of the ametryne was recovered from a two-dimensional chromatogram. Recoveries of ametryne from water and soil samples ranged between 78 and 88%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...