  • 1
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Hemihepatektomie ; Hämodynamik ; Oxygenierung ; Lebervenenkatheter ; Key words Hemihepatectomy ; Hemodynamic ; Oxygenation ; Liver venous catheter
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Objective: The aim of this study was to compare low dose dopamine and dopexamine with respect to of liver-venous oxygen saturation, oxygen delivery and – demand, liver function tests and cardiocirculatory effects in the reperfusion period during a hemihepatectomy operation with occlusion of the liver hilus. Methods: Twenty patients were studied in a randomised, doubleblind setting. They either received 2 µg/kg per min dopamine or 0.5 µg/kg per min dopexamine perioperatively. For monitoring purposes a pulmonary artery and a liver venous catheter were placed. At four different time points hemodynamic parameter were assessed and blood samples were drawn. Results: Significant changes between groups were found 5 min after opening the liver hilus for the cardiac index and the systemic oxygen delivery, as well as at the end of the operation for pulmonary shunt volume, which had increased more in the dopexamine group. No significant difference between liver venous oxygen saturation and liver function tests was found. Conclusion: Until more detailed studies concerning the influence of dopamine on the hepatic-splanchnic region during liver surgery are performed, dopexamine can not be considered superior to dopamine during these operations.
    Notes: Zusammenfassung Fragestellung: Gibt es einen Unterschied bezüglich der leber-venösen Sauerstoffsättigung, des Sauerstoffangebots und -verbrauchs, der Leberfunktion sowie der kardiozirkulatorischen Effekte während der Reperfusion zwischen niedrig dosiertem Dopamin und Dopexamin bei Leberteilresektionen mit Leberhilusokklusion? Methodik: 20 Patienten wurden randomisiert, doppelblind in zwei Gruppen eingeteilt und erhielten entweder 2 µg/kg/min Dopamin oder 0,5 µg/kg/min Dopexamin. Für das perioperative Monitoring wurden ein pulmonalarterieller- und ein Lebervenenkatheter gelegt. Zu vier Meßzeitpunkten wurden Parameter der Hämodynamik erhoben und Blut abgenommen. Ergebnisse: Ein signifikanter Unterschied zwischen den Gruppen bestand 5 min nach Eröffnung des Leberhilus in einem stärker angestiegenen Cardiacindex und systemischen Sauerstoffangebot sowie am OP-En-de in einem stärker angestiegenen pulmonalen Shuntvolumen in der Dopexamingruppe. Es gab keinen Unterschied bezüglich der leber-venösen Sauerstoffsättigung und der Leberfunktionsparameter. Schlußfolgerung: Bis weiterführende Untersuchungen mit differenzierter Betrachtung der Wirkung von Dopexamin bei leber-chirurgischen Eingriffen vorliegen, ist Dopexamin bei diesen Operationen gegenüber Dopamin nicht als überlegen zu betrachten.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0495
    Keywords: Key words Geochemistry ; Porosity ; Radioactivity ; Radon
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences
    Notes: Abstract  A steady radon exhalation is assumed in most publications. In a village of North-East Hungary, however, high radon concentrations have been measured, differing strongly in neighbouring houses and varying in time, due to the interplay of geochemical phenomena.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 22 (1996), S. 1466-1467 
    ISSN: 1432-1238
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-1238
    Keywords: Key words Hydroxyethyl starch ; Modified fluid gelatin ; Chloride ; Anion gap ; Acid base ; Saline
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In ten piglets (body weight 8.2–11.6 kg), acid base, electrolyte and anion gap changes were investigated during almost total plasma replacement with hydroxyethyl starch (HES) and modified fluid gelatin (GEL) in saline solution using a cell saver autotransfusion technique. During the study, there were only moderate acid base changes, but marked disturbances in anion balance. At study end, the mean chloride concentration was significantly higher (mmol/l: normal values 97–108, HES 116 ± 1.5, GEL 108 ± 1.1, p 〈 0.01) and the mean anion gap was significantly lower in the HES group in comparison to the GEL group (mmol/l: normal values 5–14, HES 3 ± 1.7, GEL 11.9 ± 0.9, p 〈 0.01). It is concluded that plasma replacement with electroneutral HES, but not with negatively charged GEL, can lower the anion gap irrespective of the underlying disease. This can be misleading when the anion gap is used for differential diagnosis of metabolic acidosis in patients after large volume infusion of synthetic colloids.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-1238
    Keywords: Key words Transportation of patients ; Critical illness ; Mechanical ventilation ; Critical care ; Predictors
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objectives: Critically ill patients are often transferred due to the growing number of diagnostic procedures required to be performed outside the intensive care unit. These transfers have proved to be very critical. The aim of this study was to evaluate predictors for the deterioration of respiratory function in critically ill patients after transfer. Design: Prospective, clinical, observational study. Setting: 1800-bed university teaching hospital. Subjects: 98 mechanically ventilated patients were investigated during transfer. Measurement and main results: Before transfer, all patients were classified according to the Acute Physiology and Chronic Health Evaluation (APACHE) II score and the Therapeutic Intervention Scoring System (TISS). Haemodynamics and arterial blood gases were measured at 11 different times. Arterial oxgen tension (PaO2), fractional inspired oxygen (FIO2), PaO2/FIO2 ratio, lowest PaO2/FIO2 ratio, minimal PaO2 and maximal FIO2, APACHE II score, TISS before transfer, age and duration of transfer were analysed as potential predictors for deterioration of respiratory function after transfer. Variables were analysed using Classification and Regression Trees and Clustering by Response. In 54 transports (55 %) there was a decrease in the PaO2/FIO2 ratio, and a decrease of more than 20 % from baseline was noted in 23 of the transferred patients (24 %). Age 〉 43 years and FIO2 〉 0.5 were identified as predictors for respiratory deterioration. Conclusions: Our predictors were able to indicate deterioration after transfer correctly in 20 of 22 patients (91 %), combined with a false-positive rate in 17 of 49 (35 %).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-1238
    Keywords: Key words C1-esterase inhibitor ; Complement system ; Sepsis ; Liver transplantation ; Caroli's disease ; Colloid osmotic pressure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The extent of complement and contact activation is related to outcome in sepsis. A low functional index of their main blocker C1-esterase inhibitor (C1-INH) is considered as a relative deficiency of C1-INH and might contribute to the development of fatal complications in the intensive care unit. The first results of therapeutic intervention with C1-INH concentrate in septic shock are promising. We report on our experience of C1-INH concentrate administration in a young woman with Caroli's disease as ultimate rescue therapy for septic shock with capillary leakage syndrome after combined liver and kidney transplantation. No focus of infection was detectable and thus surgical intervention was not indicated. Antibiotic therapy at that time included vancomycin, tobramycin, meropenem and fluconazol. Hemodynamic stabilization occurred within hours after administration of C1-INH concentrate. Simultaneously a reduction in vasopressor medication was possible and negative fluid balance was achieved.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' journal of analytical chemistry 358 (1997), S. 105-107 
    ISSN: 1432-1130
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Crystalline strontium titanate layers were deposited on titanium anodes from Sr(OH)2 aqueous electrolyte solutions by a plasmachemical-electrochemical process of anodic spark deposition. X-ray diffraction (XRD), scanning electron microscopy (SEM) and transmission electron microscopy (TEM) have been used to study the properties of the polycrystalline material. Strontium titanate was deposited on the titanium anode surface as a ceramic layer from an aqueous electrolyte. The typical pore structure morphology of the anodic spark deposit (ASD) was characterized by SEM as well as fractures which provide an intimate contact between layer and substrate. XRD-study showed that the layers are composed of a mixture of SrTiO3 and TiO2.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' journal of analytical chemistry 365 (1999), S. 255-257 
    ISSN: 1432-1130
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Reinforcement effects in composites are widely influenced by fibre coatings. A detailed understanding of their microstructure and chemical composition is of great interest. Boron nitride films were deposited continuously on fibre rovings of various ceramics in CVD reactors of vertical as well as horizontal position. XPS depth profilings show that the film compositions are close to stoichiometric BN with carbon and oxygen impurities in the range of 10 at%. Cross-sections of separated fibres were investigated by HREM and TEM diffraction. All BN films are hexagonal turbostratic. The (002) layers with an increased distance (about 0.36 nm) showed a mean stacking sequence near to graphite and a characteristic orientation to the fibre in the interface region. We assume the gas flow type and hence the exchange rate of matter and energy determines the film structure in this region. With increasing film thickness the (002) layers fold randomly in all directions or form nanocrystals at elevated temperatures.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Archives of Biochemistry and Biophysics 266 (1988), S. 285-288 
    ISSN: 0003-9861
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Biochimica et Biophysica Acta (BBA)/General Subjects 343 (1974), S. 324-329 
    ISSN: 0304-4165
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology , Medicine , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗