Skip to main content
Log in

Suitability of ion pump for evacuation of a closed He cycled Mössbauer cryostat

  • Theoretical and Experimental Developments
  • Published:
Hyperfine Interactions Aims and scope Submit manuscript

Abstract

For Mössbauer studies at very low temperatures, the target holder kept at 11°K with the help of a closed He cycle Mössbauer shroud, has to be insulated by evacuating the outside enclosure surrounding the shroud. The target is kept in thermal contact with the cryostat cold finger through He gas at atmospheric pressure. This provides a vibrationless thermal contact between the two. The evacuation of the outside chamber has to be vibration free which can be accomplished by means of a suitable ion pump which is totally vibration free. However, use of Vac-ion pump here could not be made successful because the pump did not work at all after little pumping. To find out the cause of pump's failure, RGA was employed which showed the presence of He gas in the outside chamber at the time of purging of He gas in the internal chamber. The pump, however, worked efficiently again when the dry N2 gas purged in place of Helium. This points out that totally vibration free Vac-ion pumps cannot be used for evacuation of such cryostats. Here, diffusion pump was used subsequantly taking extra precautions to minimise the vibrations.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Air-Product Operational Manual for the DMX-20 Mossbauer Cryostat and Catalog No. LCS-Aug. 1977, p-21.

  2. M. McClintock, Cryogenics (Reinhold Publishing Corporation, Chapman and Hall, London, 1964) pp. 36–61.

    Google Scholar 

  3. A. Roth, in Vacuum Technology (North Holland Amsterdam, 1982) pp 232–241 and cited references.

    Google Scholar 

  4. W.L. Fite and P. Irving, J. Vac. Sci. Technol. 11 (1974) 351–356. Also see Anavac-2 Residual Gas Analyser User's Manual p-34 (VG Gas Analysis, U.K., 1983).

    Article  Google Scholar 

  5. U.K. Chaturvedi, V. Shrinet, S.K. Agrawal and A.K. Nigam Ion Implantation: Equipments and Techniques (eds. H. Ryssel and H. Glawisching, Springer-Verlag, Berlin, 1983) pp 176–184.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Nigam, A.K., Pathak, R. & Chaturvedi, U.K. Suitability of ion pump for evacuation of a closed He cycled Mössbauer cryostat. Hyperfine Interact 42, 1153–1156 (1988). https://doi.org/10.1007/BF02395595

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02395595

Keywords

Navigation