Skip to main content
Log in

Passage of plasma through the kidney studied by external counting and autoradiography

  • Published:
Pflügers Archiv Aims and scope Submit manuscript

Summary

At different times after injection into the renal artery of131I-albumin, the distribution of the tracer in kidneys of the rabbit and the dog was illustrated by a series of autoradiograms. In order to determine the mean circulation time for albumin in the kidney, the radioactivity over the kidney was simultaneously registered by external monitoring. A short mean circulation time was measured for albumin (plasma) passing cortex, and a longer one for that fraction of the albumin that passed through medulla, papillae, and capsule. The investigation rendered probable that the mean circulation time for blood through the kidney determined by the external technique applies to blood passing cortex. The circulation times for blood through medulla, papillae, and capsule are not included in the calculation of the mean circulation time.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Deetjen, P., H. Brechtelsbauer u.K. Kramer: Hämodynamik des Nierenmarks, III. Farbstoffpassagezeiten in der äußeren Markzone und. V. renalis. Die Durchblutung in der Niere. Pflügers Arch. ges. Physiol.279, 281–293 (1964).

    Google Scholar 

  • Kramer, K., K. Thurau u.P. Deetjen: Hämodynamik des Nierenmarks, I. Capilläre Passagezeit, Blutvolumen, Durchblutung, Gewebshämatokrit und O2-Verbrauch des Nierenmarks in situ. Pflügers Arch. ges. Physiol.270, 251–269 (1960).

    Google Scholar 

  • Ladefoged, J., andF. Pedersen: Renal blood flow, circulation times and vascular volume in normal man measured by the intraarterial injection-external counting technique. Acta physiol. scand.69, 220–229 (1967).

    Google Scholar 

  • Meier, M., H. Brechtelsbauer u.K. Kramer: Hämodynamik des Nierenmarks, IV. Farbstoffverdünnungskurven in verschiedenen Abschnitten des Niernmarks. Pflügers Arch. ges. Physiol.279, 294–304 (1964).

    Google Scholar 

  • Overbeck, W.: Lichtelektrische Messungen der relativen Erythrocytenverteilung in verschiedenen Abschnitten der Hundeniere. Pflügers Arch. ges. Physiol.264, 280–293 (1957).

    Google Scholar 

  • Pedersen, F., andO. Baerenholdt: Mean circulation time and fastest circulation time for red cells and plasma in the human kidney measured by an external counting method. Scand. J. clin. Lab. Invest.18, 245–253 (1966).

    Google Scholar 

  • ——J. Ladefoged, U. Doutheil, andE. E. Selkurt: Circulation times in the dog kidney measured by an external counting technique and by a dye dilution method. Pflügers Arch. ges. Physiol.286, 36–43 (1965).

    Google Scholar 

  • Thurau, K., P. Deetjen u.K. Kramer: Hämodynamik des Nierenmarks, II. Wechselbeziehung zwischen vasculärem und tubulärem Gegenstromsystem bei arteriellen Drucksteigerungen, Wasserdiurese und osmotischer Diurese. Pflügers Arch. ges. Physiol.270, 270–285 (1960).

    Google Scholar 

  • Zierler, K. L.: Circulation times and the theory of indicator-dilution methods for determining blood flow and volume, p. 591. Handbook of Physiology. Am. Physiol. Soc. Washington 1962.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

The work was supported by a grant from King Christian X's Foundation

Rights and permissions

Reprints and permissions

About this article

Cite this article

Pedersen, F. Passage of plasma through the kidney studied by external counting and autoradiography. Pflugers Arch. 305, 96–104 (1968). https://doi.org/10.1007/BF00586398

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00586398

Key-Words

Schlüsselwörter

Navigation