Abstract
The aim of this study was to define the most efficient way of performing cardiac MRI for anatomic information in small experimental animals, using a vertical magnetic field with a strength of 0.3 T (FONAR beta-3000M). This information may be used to improve cardiac MRI in infants and small children, since the size of a rabbit is considered comparable to that of a neonate. Experimental axial cardiac MRI studies were performed in a rabbit under general anesthesia in order to study the effects on image quality of changing various imaging parameters. These are ECG-gating, number of excitations (averages), number of warp levels, echo time (TE) and repetition time (TR). The effects of changing the size of the field of view (FOV), the slice thickness and the phase-encoding direction were also studied. We found that ECG-gating was crucial and that three excitations, TE 16 ms, and 257 vertical phase-encoding warp levels were adequate. Five-millimeter slice thickness and FOV 20 cm were preferred.
Similar content being viewed by others
References
Fletcher BD, Jacobstein MD, Nelson, AD, Riemenschneider TA (1984) Gated magnetic resonance imaging of congenital cardiac malformations. Radiology 150: 137
Higgins CB, Byrd BF, Farmer D, Silverman NH, Cheitlin MD (1984) Magnetic resonance imaging in patients with congenital heart disease. Circulation 70: 851
Didier D, Higgins CB, Fisher MR, Osaki L, Silverman NH, Cheitlin MD (1986) Congenital heart disease: gated MR imaging in 72 patients. Radiology 158: 227
Sieverding L, Klose U, Apitz J (1990) Morphological diagnosis of congenital and acquired heart disease by magnetic resonance imaging. Pediatr Radiol 20: 311
Masui T, Seelos KC, Kersting-Sommerhoff BA, Higgins CB (1991) Abnormalities of the pulmonary veins: evaluation with MR imaging and comparison with cardiac angiography and echocardiography. Radiology 181: 645
Sechtem U, Pflugfelder PW, White RD, Gould RG, Holt W, Lipton MJ, Higgins CB (1987) Cine MR imaging potential for the evaluation of cardiovascular function. AJR 148: 239
Chrispin A, Small P, Rutter N, Coupland RE, Doyle M, Chapman B, Coxon R, Guilfoyle D, Cawly M, Mansfield P (1986) Echo planar imaging of normal and abnormal connections of the heart and great arteries. Pediatr Radiol 16: 289
Strecker EP, Holz M, Meyer-Waarden K, Diggs J, Rausch OS, James AE (1986) Influence of NMR measuring sequences and gradient variation on signals from flowing systems: magnetic resonance tomography on experimental models. Eur J Radiol 6: 53
Orbach EM (1987) Data acquisition parameters. Fonar Forum 1: 4
Larsson E-M, Nilsson H, Holtås S, Ståhlberg F (1989) Coil selection for MR imaging of the cervical and thoracic spine using a vertical magnetic field. Acta Radiol 30: 141
Wood ML, Henkelman RM (1985) MR image artifacts from periodic motion. Med Phys 12: 143
Libove JM, Singer JR (1980) Resolution and signal-to-noise relationships in NMR imaging in the human body. J Phys E 13: 38
Thickman D, Rubinstein R, Askenase A, Cabellero A (1988) Effect of phase encoding direction upon magnetic resonance image quality of the heart. Magn Reson Med 6: 390
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Malmgren, N., Laurin, S., Ståhlberg, F. et al. Optimizing conventional cardiac MRI in the rabbit at 0.3 T. Pediatr Radiol 23, 439–441 (1993). https://doi.org/10.1007/BF02012443
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02012443