Abstract
A highly standardized 99mTc-sulphur colloid was used to evaluate reticuloendothelial system (RES)-function in the normal rat and after RE blockade by gelatin (Haemaccel). Activity distribution in the animals was measured with a scintillation camera technique. Total uptake of activity in the liver was estimated. From the time-activity curves over the liver, the phagocytic index (k phag) was evaluated. Estimation of the uptake rate of the labelled colloid into the liver and into other parts of the RES was also performed using a twocompartment model. Different methods of evaluation of RE function were compared. It was shown that for a proper estimation of the RE function, the whole uptake curve must be considered. Gelatin (Haemaccel) significantly reduced the total colloid uptake by the liver. The colloid uptake rate into the liver was also significantly reduced. Liver specimens after colloid injection were examined by light and electron microscopy showing vacuolation of hepatocytes and sinusoidal cells probably due to pinocytosis. The technique described enables functional studies of the RES. It has the advantage of noninvasive registrations and is based on the same technical facilities as used for routine liver scintigraphy.
Similar content being viewed by others
References
Atkins HL, Hauser W, Richards P (1970) Factors affecting distribution of technetium sulphur colloid. J Reticuloendothel Soc 8:176–184
Barlett MS (1949) Fitting a straight line when both variables are subject to error. Biometrics 5:207–212
Berghem LE, Ahlgren LT, Grundfeldt MB, Lahnborg G, Schildt BE (1978) Heparin-induced impairment of phagocytic and catabolic functions of the reticuloendothelial system in rats. J Reticuloendothel Soc 23:21–28
Biozzi G, Benacerraf B, Halpern BN (1953) Quantitative study of the granulopoietic activity of the reticuloendothelial system II. Br J Exp Pathol 34:441–457
Boisvieux JF, Steimer JL (1979) A non-linear mathematical model for the in vivo determination of Kupffer cells number and rate of phagocytosis of radiocolloids in rats. Int J Biomed Comput 10:331–340
Dobson EL, Jones HB (1952) The behaviour of intravenously injected particulate material. Acta Med Scand 273 (suppl):1–71
Harper PV, Lathrop KA, Jimenez F (1965) Technetium 99-m as a scanning agent. Radiology 85:101
Houston AS, Macleod MA (1980) Processing of liver dynamic studies with technetium-labelled sulphur colloid. Br J Radiol 53:87–92
Hübner G (1968) Die pathischen Reaktionen des Lebergewebes. Eine elektronenmikroskopische Studie. Veroeff Pathol 78:1–186
Old L, Benacerraf B, Clarke D, Carswell E, Stockert E (1961) The role of the reticuloendothelial system in the host. Cancer Res 21:1281–1301
Persson BRR, Naversten Y (1970) Technetium-99m sulphur colloid preparation for scintigraphy of the reticuloendothelial system. Acta Radiol [Ther] (Stockh) 9:567–576
Persson BRR, Strand S-E, Knöös T (1978) Radioanalytical studies of 99Tcm-labelled colloids and macromolecules using gel chromatography column scanning technique. J Radioanal Chem 43:275–286
Pirttiaho HI, Pitkänen U (1977) Size and blood flow of the liver estimated by 99Tcm scanning. Acta Radiol [Ther] (Stockh) 16:497–506
Saba TM (1970) Physiology and physiopathology of the reticuloendothelial system. Arch Intern Med 126:1031–1052
Schildt B, Bouveng R, Sollenberg M (1975) Plasma substitute induced impairment of the reticuloendothelial system function. Acta Chir Scand 141:7–13
Scott GBD, Williams HS, Marriot PM (1967) The phagocytosis of particles of different sizes. Br J Exp Pathol 48:411–416
Stern HS, McAfee JG, Subramanian G (1966) Preparation, distribution and utilization of technetium 99-m sulphur colloid. J Nucl Med 7:665–675
Strand SE (1979) Studies on parameters influencing quantitative scintillation camera measurements of in vivo radionuclide distributions. Application to functional examinations of thyroid glands, lymph nodes and kidneys. Thesis, University of Lund
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Rydén, S., Strand, SE., Palmer, J. et al. A scintillation camera technique for measurements of the reticuloendothelial function —Comparison of different methods for measuring RES function. Eur J Nucl Med 7, 16–21 (1982). https://doi.org/10.1007/BF00275239
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00275239