Skip to main content
Log in

Results of alloarthroplasty of the hip joint

  • Original Works
  • Published:
Archives of orthopaedic and traumatic surgery Aims and scope Submit manuscript

Summary

We report on the follow-up examination results of 881 operated hip joints which were implanted in the Innsbruck University Clinic for Orthopedics during the period 1968–1975. Due to exact checking 75% of all patients could be clinically control-examined during 1978 and all available information regarding the others was collected. In the patient group with an average age of 62.5 years the course of postoperative mobility over the years was mainly examined. Functional activity, subjective patient opinion, pain, work capability and weather sensitivity were also analyzed. After an implantation period of the hip prosthesis of 3–10 years encouraging results were shown. Aseptic prostheses loosenings (9.8%) were examined with regard to their causes. The infection rate was very low at 0.56% and also periarticular calcification only occurred comparatively seldom (13.5%). Other complications were recorded in 6.8% of the patients. In total, 74% of the operated patients offered a very good or good complete result.

Zusammenfassung

Wir berichten hier über die Nachuntersuchungsergebnisse an 881 operierten Hüftgelenken, die im Zeitraum 1968 bis 1975 an der Orthopddischen Universitätsklinik implantiert wurden. Durch genaue Recherchen konnten 75% aller Patienten im Laufe des Jahres 1978 klinisch nachuntersucht wurden, über den Rest wurden alle erhdltlichen Informationen gesammelt. An dem Patientengut mit einem Durchschnittsalter von 62,5 Jahren wurde vor allem die postoperative Beweglichkeit im Verlauf der Jahre untersucht. Auch die funktionelle Aktivität, subjektives Patientenurteil, Schmerzen, Arbeitsfähigkeit und Wetterfühligkeit wurden analysiert. Es zeigten sich nach drei- bis zehnjähriger Implantationszeit der Hüftprothesen ermutigende Ergebnisse. Auch 9,8% aseptische Prothesenlockerungen wurden hinsichtlich ihrer Ursachen untersucht. Die Infektionsrate liegt mit 0,56% sehr nieder, auch periartikuldre Verkalkungen traten nur in einem vergleichsweise kleinem Prozentsatz auf (13,5%). Sonstige Komplikationen zählten wir bei 6,8% der Patienten. Insgesamt boten 74% der operierten Patienten ein sehr gutes oder gutes Gesamtergebnis.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Abele H, Steinhäuser J (1972) Histomorphologische Untersuchungen zur Spätlockerung des Pfannenteils bei Totalprothesen der Hüfte. Z Orthop 110:412–417

    Google Scholar 

  2. Amstutz HC, Maki S (1978) Complications of trochanteric osteotomy in total hip replacement. J Bone Jt Surg 60-A: 214–216

    Google Scholar 

  3. Bauer R, Jopp M (1974) Resultate der totalen Hüftprothe-sen. Arch Orthop Unfall-Chir 78:325–335

    Google Scholar 

  4. Bauer R, Semenitz E (1976) Möglichkeit der Infektionsprophylaxe bei Alloarthroplastiken. Orthop Praxis 7:689–693

    Google Scholar 

  5. Bauer R (1978) Prothetischer Gelenksersatz. Acta Chir Austr 10 FB:69–75

    Google Scholar 

  6. Bauer R, Kerschbaumer F, Poisl S, Oberthaler W (1979) The transgluteal approach to the hip joint. (In press)

  7. Beck H (1977) Infektionen nach Alloplastik der Hüfte. Chirurg 48:17–21

    Google Scholar 

  8. Beckenbaugh RD, Ilstrup DM (1978) Total hip arthroplasty. J Bone Jt Surg 60-A:306–313

    Google Scholar 

  9. Boitzy A, Zimmermann H (1969) Komplikationen bei Totalprothesen der Hüfte. Arch Orthop Unfall-Chir 66: 192–200

    Google Scholar 

  10. Boitzy A (1973) Allgemeine operative Komplikationen bei Totalprothesen der Hüfte. In: Cotta H, Schulitz KP (Hrsg) Der totale Hüftgelenksersatz. Stuttgart, G. Thieme

    Google Scholar 

  11. Bopp HM, Goymann V (1974) Biomechanische Gesichtspunkte zur Implantation von Hüfttotalprothesen bei doppelseitiger Coxarthrose. Orthop Praxis 8:138–150

    Google Scholar 

  12. Bopp HM, Goymann V (1973) Spezielle Gesichtspunkte der Physiotherapie nach Alloarthroplastik am Hüftgelenk. Z Orthop 111:580–581

    Google Scholar 

  13. Bopp HM (1974) Postoperative Behandlung nach Alloarthroplastik des Hüftgelenkes. München, SchwarzeckVerlag

    Google Scholar 

  14. Breitenfelder J, Port J (1973) Hat die Hüftgelenksarthro-dese in der Kombination mit der totalen Endoprothese ihre Berechtigung? Z Orthop 111:237–243

    Google Scholar 

  15. Breitenfelder J, Weidner R (1976) Die elektrogalvanische Entzündung als Ursache der aseptischen Implantatlockerung bei der Alloarthroplastik des Hüftgelenkes. Z Orthop 114:867–870

    Google Scholar 

  16. Brinkmann KE, Heilmann K (1974) Klinische, róntgenologische und feingewebliche Untersuchungen an ausgelockerten Hüftgelenksprothesen. Arch Orthop Unfall-Chir 80:333–342

    Google Scholar 

  17. Buchholz HU (1973) Die tiefe Infektion bei der totalen Endoprothese. In: Cotta H, Schulitz KP (Hrsg) Der totale Huftgelenksersatz. Stuttgart, G. Thieme

    Google Scholar 

  18. Burckhard A, Taillard W (1975) Elektromyographische Untersuchung der statischen und dynamischen Funktion der Hüfte nach Totalendoprothese. Z Orthop 113:322–331

    Google Scholar 

  19. Burton DS, Schurmann DJ (1975) Hematogenous infection in bilateral total hip artroplasty. J Bone Jt Surg 57-A: 1004–1005

    Google Scholar 

  20. Charnley J (1961) Arthroplasty of the hip. A new operation. Lancet 1:1129–1132

    Google Scholar 

  21. Charnley J (1975) Fracture of femural protheses in total hip replacement. Clinical Orthop 3:105–120

    Google Scholar 

  22. Clegg J (1977) The results of the pseudarthrosis after removal of an infected total hip prosthesis. J Bone Jt Surg 59-B:298–301

    Google Scholar 

  23. Coventry MB, Beckenbaugh RD, Nolan DR, Ilstrup DM (1974) 2,012 total hip arthroplasties: A study of postoperative course and early complications. J Bone Jt Surg 56-A:273–284

    Google Scholar 

  24. Convery R, Gunn DR, Huges JD, Martin WE (1975) The relative safety of polymethylmethacrylate. J Bone Jt Surg 57-A:57–64

    Google Scholar 

  25. Cotta H, Schulitz KP (1973) Der totale Hüftgelenksersatz. Stuttgart, G. Thieme

    Google Scholar 

  26. Decoulx J (1972) Prothèse de Charnley-Müller. SO.F.C. O.T. XLIXe Réunion Anuelle

  27. Diehl K (1975) Knochenbeanspruchung und Knochenumbau bei der Alloarthroplastik des coxalen Femurendes mit Zementverankerung. Arch Orthop Unfall-Chir 83:928

    Google Scholar 

  28. Dietschi C (1979) 10-Jahres-Resultate. Hüfttotalprothesen Balgrist 1962–1968. Orthopäde 8:87–90

    Google Scholar 

  29. Eggert A, Seidel H, Ruhnke J (1977) Beitrag zur Frage periartikulärer Verkalkungen nach totalendoprothetischem Hüftgelenksersatz. Arch Orthop Unfall-Chir 87:343–348

    Google Scholar 

  30. Eichler J (1973) Über einen Stützring zur Verankerung der Kunststoffpfanne für die operative Behandlung der Protrusio acetabuli. MOT 93:28–31

    Google Scholar 

  31. Elson RA, Jephcott AE, McGechie DB, Verettas D (1977) Antibiotic-loaded acrylic cement. J Bone Jt Surg 59-B: 200–205

    Google Scholar 

  32. Endler M (1977) Probleme der Belastungsmessung bei Hüftendoprothesen. Orthop Prax 7:684–688

    Google Scholar 

  33. Feith R, Sloof TJJH, Kazem I, Van Rens ThJG (1976) Strontium 87m SR bone scanning for the evaluation of total hip replacement. J Bone Jt Surg 58-B:79–83

    Google Scholar 

  34. Fischer LP, Gonon GP, Carret JP, Vulliez Y, de Mourgues G (1977) Association méthacrylate de méthyle (ciment acrylique) et antibiotiques. Rev Chir Orthop 63:361–372

    Google Scholar 

  35. Ganz R, Rüter A (1973) Totalprothesen nach Hüftarthro-desen. Z Orthop 111:433–435

    Google Scholar 

  36. Gershuni DH, Axer A, Segal D, Halperin N (1974) Total hip replacement arthroplasty. Arch Orthop Unfall-Chir 79:217–227

    Google Scholar 

  37. Griss P, Heimke G, Werner E, Bleicher J, Jentschura G (1978) Was bedeutet die Resorption des Calcar femoris nach der Totalendoprothese noperation der Hüfte? Arch Orthop Traumat Surg 92:225–232

    Google Scholar 

  38. Gschwend N, Scherrer H, Dybowski R, Hohermuth H, Razavi R, Staubli A, Wüthrich B, Scherrer A (1977) AIlergologische Probleme in der Orthopäde. Orthopdde 6: 197–204

    Google Scholar 

  39. Guzzanti V, Greco F, De Rossi G, Focacci C (1977) Die Toleranz bei Hüftgelenkprothesen bewertet durch szintigraphische Studien. Arch Orthop Unfall-Chir 88:87–101

    Google Scholar 

  40. Hackenbroch HM, Bruns H, Holbe R, Lechleuthner H (1976) Weitere Erfahrungen mit der Totalendoprothese des Hüftgelenkes. Arch Orthop Unfall-Chir 84:149–168

    Google Scholar 

  41. Häckel H, König B, Mostbeck A, Pflüger W (1978) Zur Wertigkeit der Knochenszintigraphie bei Kunstgelenklockerungen. Z Orthop 116:727–731

    Google Scholar 

  42. Halawa M, Lee AJC, Ling RSM, Vangala SS (1978) The shear strength of trabecular bone from the femur, and some factors affecting the shear strength of the cement-bone interface. Arch Orthop Traumat Surg 92:19–30

    Google Scholar 

  43. Hanslik L (1973) Der alloplastische Ersatz des Hüft-gelenkes bei ausgeprägter Pfannendysplasie. Z Orthop 111: 17–23

    Google Scholar 

  44. Hanslik L, Randolff H (1974) Der Krankheitswert parartikulärer Verknöcherungen nach totalendoprothetischem Gelenksersatz. Arch Orthop Unfall-Chir 80:153–164

    Google Scholar 

  45. Hessert GR (1970) Wie rotiert die Rotations-Totalprothese des Hüftgelenkes in vivo? Arch Orthop Unfall-Chir 68: 343–350

    Google Scholar 

  46. Hessert GR, Jänger M, Krippendorf B (1972) Ergebnisse der totalen Hüftendoprothese. Arch Orthop Unfall-Chir 72:305–338

    Google Scholar 

  47. Hessert GR, Schildhauer M, Störzinger Th (1973) Großer Kopf — kleine Pfanne: Das Schicksal des Rotationshüft-kopfes nach fehlerhafter Implantation. Arch Orthop Unfall-Chir 74:301–316

    Google Scholar 

  48. Hill J, Klenerman L, Trustey S, Blowers R (1977) Diffusion of antibiotics from acrylic bone-cement in vitro. J Bone Jt Surg 59-B:197–199

    Google Scholar 

  49. Hohmann D (1973) Allgemeine und besondere Indikation der Totalalloplastik des Hüftgelenkes In: Cotta H, Schulitz KP (Hrsg) Der totale Huftgelenksersatz. Stuttgart, G. Thieme

    Google Scholar 

  50. Holz U, Gubba HJ (1974) Zur Problematik des Prothesenwechsels bei Lockerungen und Infektionen des alloarthroplastischen Hüftgelenksersatzes. Arch Orthop Unfall-Chir 80:165–175

    Google Scholar 

  51. Holz U, Ungethiim M (1975) Klinische und experimentelle Untersuchungen wesentlicher Faktoren bei der dauerhaften Verankerung von Hüftendoprothesen. Arch Orthop Unfall-Chir 82:195–204

    Google Scholar 

  52. Holz U, Kraner F, Weller S (1977) Periartikuläre Verkalkungen nach Hüfttotalendoprothesen. Z Orthop 115:146–158

    Google Scholar 

  53. Huggler AH, Schreiber A (1973) Alloarthroplastik des Hüftgelenkes 2. überarb and erw Aufl. Stuttgart, G. Thieme

    Google Scholar 

  54. Huggler AH, Jacob HAC, Schreiber A (1978) Biomechanische Analyse der Lockerung von Femurprothesen. Arch Orthop Traumat Surg 92:261–272

    Google Scholar 

  55. Hunter G, Dandy D (1977) The natural history of the patient with an infected total hip replacement. J Bone Jt Surg 59-B:293–297

    Google Scholar 

  56. Kantor E (1977) Szintigraphie bei Totalendoprothese der Hüfte. Orthop Praxis 7:682–683

    Google Scholar 

  57. Karpf PM, Ludwig U, Beck W (1977) Periphere Nervenläsionen beim prothetischen Hüftgelenksersatz. Orthop Praxis 7:675–677

    Google Scholar 

  58. Keyl W, Hepp WR (1973) Informationswert der Hüft-arthrographie bei Verdacht auf Prothesenlockerung. Arch Orthop Unfall-Chir 77:330–338

    Google Scholar 

  59. Khan MAA, O'Driscoll M (1977) Fractures of the femur during total hip replacement and their management. J Bone Jt Surg 59-B:36–41

    Google Scholar 

  60. Kotz R (1977) Die operative Therapie der idiopathischen Hüftkopfnekrose mit besonderer Berücksichtigung der Endoprothese. Orthop Praxis 7:669–674

    Google Scholar 

  61. Lee JC, Ling RS, Vangala SS (1978) Some clinically relevant variables affecting the mechanical behaviour of bone cement. Arch Orthop Traumat Surg 92:1–18

    Google Scholar 

  62. Lehmann A (1979) 10-Jahres-Kontrolle der Hüfttotalendo-prothesen. Orthopädie 8:75–78

    Google Scholar 

  63. Linkesch W, Bergmann H, Endler F, Kolarz G, Höfer R, Nuklearmedizinische Untersuchungen zur Einheilung von Hüftgelenksendoprothesen. Z Orthop 115:108–112

  64. Ludewig R, Nöh E (1977) Aussagekraft und Wert der Szintigraphie Bowie Äquidensitenfotographie bei Endoprothesenlockerung. Orthop Praxis 7:678–681

    Google Scholar 

  65. Maier S, Griss P, Rahmfeld T, Dinkelacker T (1977) Nachuntersuchungsergebnisse der totalen Alloarthroplastik der Hüfte unter besonderer Berücksichtigung der Spätkompli-kationen 4–7 Jahre post operationem. Z Orthop 115:274–283

    Google Scholar 

  66. Mueller ME (1970) Total hip prosthesis. Clin Orthop 72: 46–68

    Google Scholar 

  67. Mueller ME (1972) Die Infektionen und ihre Verhütung bei der Implantatchirurgie. Sonderdruck aus dem Bericht über die Unfallmedizinische Arbeitstagung des Landesverbandes Nordwestdeutschland der gewerblichen Berufsgenossenschaften in Göttingen

  68. Mueller ME, Elmiger B (1979) Coxarthrose: 10-Jahres-Ergebnisse der sogenannten Setzholz-Totalprothese. Orthopdde 8:73–74

    Google Scholar 

  69. Münzenberg KJ, Dennert R (1975) Pfannenlockerung bei Hüfttotalendoprothesen. infolge altersabhängigen Knochensubstanzverlust. Z Orthop 113:947–951

    Google Scholar 

  70. Niederer PG, Chiquet C, Eulenberger J (1978) Htiftendoprothesen mit oberfldchenstrukturierten Verankerungsschdften. Unfallheilkunde 81:205–210

    Google Scholar 

  71. Nolan DR, Fitzgerald RH, Jr, Beckenbaugh RD, Coventry MB (1975) Complications of total hip arthroplasty treated by reoperation. J Bone Jt Surg 57-A:977–981

    Google Scholar 

  72. Oberthaler W, Bauer R (1978) Die operative Therapie von Skeletmetastasen. MOT 98:187–190

    Google Scholar 

  73. Oest O, Müller K, Hupfauer W (1975) Die Knochenzemente. Stuttgart, F. Enke

    Google Scholar 

  74. Plane R., Städtler J (1975) Infizierte Huftendoprothesen — ein aktuelles Problem. Z Orthop 113:965–973

    Google Scholar 

  75. Probst KJ, Herp A, Leidel W (1978) Stereo-Radiologische Lokalisationsdiagnostik von Schalen- und Totalendoprothesen des Hüftgelenkes. Arch Orthop Traumat Surg 92:75–81

    Google Scholar 

  76. Reichelt A, Riedl K (1974) Mehrfachoperationen nach Totalprothesen des Htiftgelenkes. Arch Orthop Unfall-Chir 79:29–43

    Google Scholar 

  77. Reichelt A, Brand A (1975) Das Verhalten der Blutsenkungsgeschwindigkeit nach der Implantation von Totalendoprothesen des Hüftgelenkes. Z Orthop 113:900–903

    Google Scholar 

  78. Ring PA (1974) Total replacement of the hip joint. J Bone Jt Surg 56-B:44–58

    Google Scholar 

  79. Rohlmann A, Kölbel R, Bergmann G (1977) Kritische Betrachtung zur Berechnung der Belastung von Femur und Huftendoprothesen bei einer angenommenen Lagerung in maximal drei Punkten. Z Orthop 115:89–95

    Google Scholar 

  80. Rosemeyer B, Jäger M, Witt AN (1973) Femurfrakturen bei Totalendoprothesen. Arch Orthop Unfall-Chir 76:40–53

    Google Scholar 

  81. Rosemeyer B, Pförringer W (1976) Zur Problematik des Hüftgelenksersatzes. mit Prothesenteilen aus Polyester. Arch Orthop Unfall-Chir 85:111–117

    Google Scholar 

  82. Ruckelshausen MC (1973) Haltbarkeitserwartung von Hüfttotalprothesen in Abhdngigkeit von Verschleiß, Reibungskoeffizient und Kopfdurchmesser. In: Cotte H, Schulitz (Hrsg) Der totale Hüftgelenksersatz. Stuttgart, G. Thieme

    Google Scholar 

  83. Rütt A (1977) Ätiopathogenese der aseptischen Auslockerung von Huftgelenkstotalendoprothesen. Arch Orthop Unfall-Chir 88:139–152

    Google Scholar 

  84. Safi R, Schreiber A (1972) Ergebnisse der Hüftendototal-plastik. (Kontrolle der 1962–1968 operierten Fälle). Z Orthop 110:83–89

    Google Scholar 

  85. Scott RD, Turner RH, Leitzes SM, Aufranc OE (1975) Femoral fractures in conjunction with total hip replacement. J Bone Jt Surg 57-A:494–501

    Google Scholar 

  86. Schellmann WD, Vittali HP (1975) Diagnostik der Lockerung von Huftgelenkstotalendoprothesen. Chir Prax 19: 108–113

    Google Scholar 

  87. Scherrer U (1976) Pfannenfrakturen bei den alten CharnleyProthesen. Z Orthop 114:949–960

    Google Scholar 

  88. Schneider R (1978) Totalprothesen der Hüfte: Die Verkeilung der Schaftprothese als Prinzip. Unfallheilkunde 81: 255–260

    Google Scholar 

  89. Schulitz KP, Dustmann HO (1976) Komplikationen der Totalendoprothese. Arch Orthop Unfall-Chir 85:33–50

    Google Scholar 

  90. Schulze W (1974) Die Behandlung der gelockerten und infizierten Totalendoprothese des Hüftgelenkes. MOT 94: 13–18

    Google Scholar 

  91. Shepherd MM (1954) Assessment of function after arthroplasty of the hip. J Bone Jt Surg 36-B:354–363

    Google Scholar 

  92. Shepherd MM (1960) A review of 650 hip arthroplasty operations. J Bone Jt Surg 42-B: 177–204

    Google Scholar 

  93. Stock D, Rösch H, Dumpert HP, Beck W (1975) Ergebnisse der totalen Huftendoprothesen. Arch Orthop Unfall-Chir 82:183–193

    Google Scholar 

  94. Stübner G, Matz K (1977) Modifizierter Agardiffusionstest zur direkten Prüfung der Wirksamkeit freigesetzter Antibiotica aus Knochenzementen. Chirurg 48:604–606

    Google Scholar 

  95. Stuhmer G, Weber BG (1978) Die neue Rotationshüftendo-prothese nach dem Baukastenprinzip, System Weber. Z Orthop 116:285–293

    Google Scholar 

  96. Teubner E, Kottmann B (1976) Vergleichende Analyse der Schaftgeometrie häufig verwendeter Endoprothesen für das Hüftgelenk. Chirurg 47:674–681

    Google Scholar 

  97. Tönnis D, Asai H (1976) Untersuchungen über die Lockerungsraten verschiedener Hüftgelenksprothesen. mit unterschiedlichen Halslängen. Arch Orthop Unfall-Chir 86: 317–332

    Google Scholar 

  98. Vogt KH, Krause W (1976) Infektrate nach Hüftgelenks-Totalendoprothesen-Operationen in einer Orthopadischen Klinik ohne Sterilbox. Z Orthop 114:350–354

    Google Scholar 

  99. Volz RG, Wilson RJ (1977) Factors affecting the mechanical stability of the cemented acetabular component in total hip replacement. J Bone Jt Surg 59-A:501–503

    Google Scholar 

  100. Weber, BG (1970) Die Rotations-Totalendoprothese des Hüftgelenkes. Z Orthop 105:304–315

    Google Scholar 

  101. Weber BG, Stuhmer G, Meierhans R (1971) Sterile Operationsboxen. Z Orthop 109:803–813

    Google Scholar 

  102. Weber BG, Stuhmer G (1973) Gute und schlechte Erfahrungen mit der Totalprothese des Hüftgelenkes. In: Cotta H, Schulitz KP (Hrsg) Der totale Hüftgelenksersatz. Stuttgart, G. Thieme

    Google Scholar 

  103. Weidmann E, Bereiter H, Schwarzenbach U, Huggler AH Langzeitergebnisse nach Total endoprothesen der Hüfte Orthopäde 8:83–86

  104. Weigand H, Ritter G, Schweikert CH (1978) Zur Osteosynthese und gleichzeitiger Verankerung einer Hüftprothe-senpfanne bei instabilem Acetabulum. Arch Orthop Traumat Surg 92:53–58

    Google Scholar 

  105. Weigert M, Viernstein K (1969) Ergebnisse und Komplikationen nach Endoprothesenoperationen an der Hüfte. Z Orthop 106:122–129

    Google Scholar 

  106. Weigert M, Friedebold G, Klems H (1971) Fehler und Gefahren beim totalen Hüftgelenksersatz. Z Orthop 109:659–675

    Google Scholar 

  107. Weigert M, Klems H, Friedebold G (1973) Die Friihluxation der Weber-Huggler-Prothese. Arch Orthop Unfall-Chir 77:52–54

    Google Scholar 

  108. Willert HG (1973) Die Reaktion des knöchernen Implantatlagers auf Methylmethacrylatzement. In: Cotta H, Schulitz KP (Hrsg) Der totale Hüftgelenksersatz. Stuttgart, G. Thieme

    Google Scholar 

  109. Willert HG, Semlitsch M (1973) Die Reaktion der periartikularen Weichteile auf Verschleißprodukte von Endoprothesenwerkstoffen. In: Cotta H, Schulitz KP (Hrsg) Der totale Hüftgelenksersatz. Stuttgart, G. Thieme

    Google Scholar 

  110. Willert HG, Semlitsch M, Buchhorn G, Kriete U (1978) Materialverschleiß und Gewebereaktion bei künstlichen Gelenken (Histopathologie, Biokompatibilität, biologiche und klinische Probleme). Orthopäde 7:62–83

    Google Scholar 

  111. Witt AN (1977) Möglichkeiten und Grenzen des Endoprothesenaustausches. Arch Orthop Unfall-Chir 88:1–5

    Google Scholar 

  112. Witt AN, Hackenbroch MH, Hepp WR (1972) Die Implantation von Totalendoprothesen am Hüftgelenk. unter erschwerten lokalen Bedingungen. Arch Orthop Unfall-Chir 72:289–304

    Google Scholar 

  113. Witt AN, Hackenbroch MH (1976) Therapeutische Mög-lichkeiten bei gelockerten Hüfttotalprothesen. Z Orthop 114:330–341

    Google Scholar 

  114. Wizgall J (1973) Vergleichende Untersuchungen bei der Implantation von Hüftgelenkstotalprothesen. Arch Orthop Unfall-Chir 75:65–68

    Google Scholar 

  115. Wolf L (1978) Erfahrungen bei 77 Hüftgelenksprothesen-wechseln. Z Orthop 116:248–254

    Google Scholar 

  116. Zsernaviczky J, Siemsen CH, Dahmen G (1975) Ermü-dungsbrüche im vorderen Beckenbereich nach Hüftendo-prothesen aus statisch-dynamischer Sicht. Z Orthop 113: 367–371

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Oberthaler, W., Bauer, R. & Sattler, K. Results of alloarthroplasty of the hip joint. Arch. Orth. Traum. Surg. 96, 247–258 (1980). https://doi.org/10.1007/BF00432862

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00432862

Keywords

Navigation