Skin blood flow changes in anaesthetized humans: comparison between skin thermal clearance and finger pulse amplitude measurement

  • Published:
European Journal of Applied Physiology and Occupational Physiology Aims and scope Submit manuscript

Summary

The effect of general anaesthesia on skin blood flow in the left hand, measured by a new non-invasive probe using the thermal clearance method was examined. A mercury silastic gauge was placed around the third left finger and the plethysmographic wave amplitude was recorded to measure changes in finger pulse amplitude. Heart rate (HR), mean arterial blood pressure (MABP) and skin temperature were also recorded. General anaesthesia was induced by droperidol and phenoperidine injection and propanidid infusion in eight female patients. Skin thermal clearance, plethysmographic wave amplitude, HR, MABP and skin temperature were 0.40±0.02 w · m−1 ‡C−1, 9±1 mm, 98±5 beats · min−1, 12.50±0.93 kPa and 33.3±3.4 ‡C respectively. The minimal value of MABP was 9.58 ±1.06 kPa, whereas skin thermal clearance, plethysmographic wave amplitude, HR and skin temperature increased to 0.45±0.02 w · m−1 ‡C−1, 29±3 mm, 110±4 beats · min−1 and 34.4±0.4 ‡C. Changes in skin thermal clearance correlated well with plethysmographic wave amplitude. Statistically significant changes in these two parameters occurred before significant change in HR, MABP or skin temperature. The results show that the new noninvasive probe using the thermal clearance method appears to be a useful device for measuring cutaneous microcirculation in anaesthetized humans, and responds more quickly than change in skin temperature, which is a delayed effect of skin blood flow change. Our results also show that the intensity of cutaneous vasodilatation induced by general anaesthesia did not relate to the vascular tone before anaesthesia.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Challoner AV (1975) Accurate measurement of skin blood flow by a thermal conductance method. Med Biol Eng 13:196–201

    Google Scholar 

  • Cunningham DJ (1970) An evaluation of heat transfer through the skin in the human extremity. In: Hardy HD, Gagge AP, Stolwijk JAJ (eds) Physiological and behaviour temperature regulation. Charles C. Thomas, Sprinfield, III, pp 302–311

    Google Scholar 

  • Detry J Mr, Brengelman GL, Rowell LB, Wyss C (1972) Skin and muscle components of forearm blood flow in directly heated resting man. J Appl Physiol 32:506–511

    Google Scholar 

  • Dittmar A, Marichy J, Grippari JL, Delhomme G, Roussel B (1982) Measurement by heat clearance of skin blood flow of healthy, burned and grafted skin. Biomedical thermology. Alan R. Liss Inc., New York NY, pp 413–419

    Google Scholar 

  • Eberhart RC, Schitzer A, Hernandez EJ (1980) Thermal dilution methods: Estimation of tissue blood flow and metabolism. Ann NY Acad Sci 335:107–131

    Google Scholar 

  • Edholm OG, Fox RH, Malcherson RK (1956) The effect of body heating on the circulation in skin and muscle. J Physiol [Lond] 134:612–619

    Google Scholar 

  • Englehart M, Kristensen JK (1983) Evaluation of cutaneous blood flow responses by133xenon washout and a laserdoppler flowmeter. J Invest Dermatol 80:12–15

    Google Scholar 

  • Gibbs AF (1933) A thermoelectric blood flow recorder in the form of a needle. Proc Soc Expl Biol Med 31:141–146

    Google Scholar 

  • Hensel H, Bender F (1956) Fortlaufende Bestimmung der Hautdurchblutung am Menschen mit einem elektrischen Warmleitmesser. Pflügers Arch 263:603–614

    Google Scholar 

  • Johnson JM, Taylor WF, Shepherd AP, Park MK (1984) Laser-Doppler measurement of skin blood flow: comparison with plethysmography. J Appl Physiol: Respirat Environ Exercise Physiol 56:798–803

    Google Scholar 

  • Levy L, Graichen H, Stolwijk JAJ, Calabresi M (1967) Evaluation of local tissue blood flow by continuous direct measurement of thermal conductivity. J Appl Physiol 22:1026–1029

    Google Scholar 

  • Lipkin M, Hardy JM (1954) Measurement of some thermal properties of human tissue. J Appl Physiol 7:212–217

    Google Scholar 

  • Longnecker DE, Harris PD (1980) Microcirculatory actions of general anesthesics. Fed Proc 39:1580–1583

    Google Scholar 

  • Phelps JA, Sass DJ (1969) A portable batter-powered instrument for visualizing the peripheral pulse wave form and pulse rate. Anesth Analg Curr Res 48:582–586

    Google Scholar 

  • Priebe L (1975) Methods of thermal blood flow measurement. Bibl Radiol 6:33–44

    Google Scholar 

  • Roberts JG (1980) Intravenous Anaesthesic Agents. The circulation in anaesthesia. Edited by Prys-Roberts. C. Blackwell Scientific Publications, Oxford, pp 459–489

    Google Scholar 

  • Robinson RE, Eastwood D (1959) Use of a photosphygmomanometer in indirect blood pressure measurement. Anesthesiology 20:704–707

    Google Scholar 

  • Roussel B, Dittmar A, Delhomme G, Grippari JL, Schmitt M (1982) Normal and pathologic aspects of skin blood flow measured by a thermal clearance method. Biomedical Thermology, Alan R. Liss Inc., New York, NY, pp 421–429

    Google Scholar 

  • Shepherd AP, Riedel GL (1982) Continuous measurement of intestinal mucosal blood flow by laser-doppler velocimetry. Am J Physiol 242:[Suppl 5] G668-G672

    Google Scholar 

  • Stern MD, Lape DL, Bowen PD, Chimoskey JE, Holloway GA Jr, Keiser HR, Bownam RL (1977) Continuous measurement of tissue blood flow by laser-doppler spectroscopy. Am J Physiol 232:[Suppl 1] H441-H448

    Google Scholar 

  • Whitney RJ (1953) The measurement of volume change in human limbs. J Physiol [Lond] 121:1–27

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Saumet, J.L., Leftheriotis, G., Dittmar, A. et al. Skin blood flow changes in anaesthetized humans: comparison between skin thermal clearance and finger pulse amplitude measurement. Europ. J. Appl. Physiol. 54, 574–577 (1986). https://doi.org/10.1007/BF00943343

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00943343

Key words

Navigation