Flattening of the infrahepatic inferior vena cava (IVC) on postcontrast computed tomographic (CT) scans has been reported as a sign of severe hypovolemia. The significance of this finding on unenhanced CT scans, however, has not been reported. We retro-spectively studied 60 consecutive outpatient abdominal CT scans in which both unenhanced and postcontrast sequences were performed. Flattening of the infrahepatic IVC on unenhanced CT images was noted in six patients (10%) without evidence of hypovolemia or extrinsic IVC compression. The degree of IVC fullness increased in 43 study patients overall (72%) after contrast administration. We propose several mechanisms for postcontrast IVC distention and conclude that a flattened infrahepatic IVC on unenhanced CT scans does not indicate hypovolemia in the absence of other suggestive clinical or CT findings.
Similar content being viewed by others
References
Jeffrey RB Jr, Federle MP. The collapsed inferior vena cava: CT evidence of hypovolemia. AJR Am J Roentgenol 1988;150: 431–2.
Jeffrey RB Jr, Federle MP. The slit inferior vena cava [letter]. AJR Am J Roentgenol 1988;151:205.
Grant E, Rendano F, Sevinc E, et al.. Normal inferior vena cava: caliber changes observed by dynamic ultrasound. AJR Am J Roentgenol 1980;135:335–8.
Rak KM, Hopper KD, Tyler HN. The slit infrahepatic IVC: pathologic entity or normal variant? J Clin Ultrasound 1991;19: 399–403.
Shanmuganathan K, Mirvis SE, Amoroso M. Periportal low density on CT in patients with blunt trauma: association with elevated venous pressure. AJR Am J Roentgenol 1993;160:279–83.
Almen T, Aspelin P, Levin B. Effect of ionic and non-ionic contrast medium on aortic and pulmonary pressure: an angiocardiographic study in rabbits. Invest Radiol 1975;10:519–25.
Sorensen L, Sunnegardh O, Svanegard J, et al. Systemic and pulmonary haemodynamic effects of intravenous infusion of nonionic isoosmolar dimeric contrast media. Acta Radiol 1994;35: 383–90.
McClennan BL, Stolberg HO. Intravascular contrast media. Radiol Clin North Am 1991;29:437–54.
Taylor, Rosenfield AT. Limitations of computed tomography in the recognition of delayed splenic rupture. J Comput Assist Tomogr 1984;8:1205–7.
Kelly J, Raptopoulos V, Davidoff A, et al. The value of noncontrast-enhanced CT in blunt abdominal trauma. AJR Am J Roentgenol 1989;152:41–6.
Shin MS, Berland LL, Ho K-J. Small aorta: CT detection and clinical significance. J Comput Assist Tomogr 1990;14:102–3.
Sivit CJ, Taylor GA, Bulas DI, et al. Posttraumatic shock in children: CT findings associated with hemodynamic instability. Radiology 1992;182:723–6.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Wachsberg, R.H., Levine, C.D. & Baker, S.R. Flattened inferior vena cava: A normal finding on unenhanced abdominal computed tomographic scan. Emergency Radiology 3, 16–19 (1996). https://doi.org/10.1007/BF01508160
Issue Date:
DOI: https://doi.org/10.1007/BF01508160