Skip to main content
Log in

The use of standards in the quantitative electron probe micro analysis of binary metal systems

  • Published:
Microchimica Acta Aims and scope Submit manuscript

Summary

For the binary metal systems investigated, the Ziebold-Ogilvie relation has been found to be valid. It has been shown that polyphase alloys may be used as calibration standards if some specific conditions are fulfilled. In connection with a long-term instability of the microprobe apparatus, the Ziebold-Ogilvie constant of the calibration curve may vary with time. There is no reason for assuming that this instability is restricted to the particular instrument used. Therefore it is recommended that one or two standard alloys be used together with the pure reference metal to determine that constant every time concentration measurements have to be performed. The effect of the long-term instability can hardly be taken into account in the usual theoretically-based correction procedures.

Zusammenfassung

Für die hier untersuchten binären Metallsysteme hat sich die von Ziebold und Ogilvie angegebene Beziehung als gültig erwiesen. Wie sich zeigen ließ, kann man mehrphasige Legierungen als Eichstandards verwenden, wenn gewisse Voraussetzungen erfüllt sind. In Zusammenhang mit der Langzeit-Instabilität der Mikrosonde kann es sein, daß sich die Konstante der Ziebold-Ogilvie-Kurve mit der Zeit ändert. Es besteht kein Grund zur Annahme, daß diese Instabilität auf das eine benutzte Instrument beschränkt ist. Daher wird empfohlen, ein oder zwei Standardlegierungen zusammen mit dem reinen Bezugsmetall zu verwenden, um jederzeit die Gewähr für einwandfreie Meßergebnisse zu haben. Die Auswirkung der Langzeit-Instabilität kann bei dem üblichen, theoretisch ermittelten Korrekturverfahren nur schwer in Rechnung gestellt werden.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. D. R. Beaman and J. A. Isasi, Materials Research and Standards, MTRSA11, No. 11, Nov. 1971, p. 8.

    CAS  Google Scholar 

  2. D. R. Beaman and J. A. Isasi, Materials Research and Standards, MTRSA11, No. 12, Dec. 1971, p. 12.

    CAS  Google Scholar 

  3. T. O. Ziebold and R. E. Ogilvie, Analyt. Chemistry36, 322 (1964).

    Article  CAS  Google Scholar 

  4. G. F. Bastin, Thesis, Eindhoven University of Technology, Netherlands, 1972. Abstract to be submitted to Trans. Metall. Soc. AIME.

  5. F. J. J. van Loo, Thesis, Eindhoven University of Technology, Netherlands, 1971. Abstract will be published in Acta Met.

  6. C. P. Heijwegen, to be submitted to Trans. Metall. Soc. AIME.

  7. J. Waldman, M. Schwartz, and S. Nash, Trans. ASM62, 818 (1969).

    CAS  Google Scholar 

  8. H. Yakowitz, in: The Electron Microprobe, edited by T. D. McKinley, K. F. J. Heinrich, and D. B. Wittry, New York: Wiley. 1966. p. 417.

    Google Scholar 

  9. J. Rexer, Prakt. Metallographie7, 599 (1970).

    CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bastin, G.F., Heijwegen, C.P., van Loo, F.J.J. et al. The use of standards in the quantitative electron probe micro analysis of binary metal systems. Mikrochim Acta 62, 617–625 (1974). https://doi.org/10.1007/BF01218197

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01218197

Keywords

Navigation