Abstract
The ionophore N,N,N′,N′-tetracyclohexyl-1,2-phenylenedioxydiacetamide (4) shows higher lipophilicity and superior Na+/K+ selectivity than the previously described N,N′-dibenzyl-N,N′-diphenyl-1,2-phenylenedioxydiacetamide (2). It is a suitable component of Na+-selective liquid membrane electrodes for the assay of Na+ in clinical analysers.
Similar content being viewed by others
References
U. Oesch, P. Anker, D. Ammann, W. Simon, in:Ion-Selective Electrodes (E. Pungor, I. Buzás, eds.), Akadémiai Kiadó, Budapest, 1985, p. 81.
G. Eisenman (ed.),Glass Electrodes for Hydrogen and Other Cations, Dekker, New York, 1967.
J. D. Czaban,Anal. Chem. 1985,57, 345A.
R. L. Berger,Biophys. J. 1978,24, 2.
Operating Manual, Part A, Electrolyte Analyzer AVL 982, August 1985, pp. A6-1, A7-6.
M. Güggi, M. Oehme, E. Pretsch, W. Simon,Helv. Chim. Acta 1976,59, 2417.
P. Anker, H.-B. Jenny, U. Wuthier, R. Asper, D. Ammann, W. Simon,Clin. Chem. 1983,29, 1508.
U. Oesch, D. Ammann, E. Pretsch, W. Simon,Helv. Chim. Acta 1979,62, 2073.
F. Vögtle, Th. Kleiner, R. Leppkes, M. W. Läubli, D. Ammann, W. Simon,Chem. Ber. 1983,116, 2028.
J. L. Toner, D. S. Daniel, M. S. Geer,United States Patent No. 4476007, 1984.
T. Shono, M. Okahara, I. Ikeda, K. Kimura,J. Electroanal. Chem. 1982,132, 99.
Hitachi Automated Blood Chemistry Analyzer, Specification Bulletin, Hitachi Ltd., Tokyo, Japan.
D. Ammann, R. Bissig, M. Güggi, E. Pretsch, W. Simon, I. J. Borowitz, L. Weiss,Helv. Chim. Acta 1975,58, 1535.
P. Anker, E. Wieland, D. Ammann, R. E. Dohner, R. Asper, W. Simon,Anal. Chem. 1981,53, 1970.
R. E. Dohner, D. Wegmann, W. E. Morf, W. Simon,Anal. Chem. 1986,58, 2585.
U. Wuthier, H.-V. Pham, B. Rusterholz, W. Simon,Helv. Chim. Acta 1986,69, 1435.
P. C. Meier,Anal. Chim. Acta 1982,136, 363.
G. G. Guilbault, R. A. Durst, M. S. Frant, H. Freiser, E. H. Hansen, T. S. Light, E. Pungor, G. Rechnitz, N. M. Rice, T. J. Rohm, W. Simon, J. D. R. Thomas,Pure Appl. Chem. 1976,48, 127.
U. Oesch, W. Simon,Anal. Cbem. 1980,52, 692.
H. Ellgehausen, Ch. D'Hondt, R. Fürer,Pestic. Sci. 1981,12, 219.
U. Oesch, O. Dinten, W. Simon, in preparation.
G. Eisenman, D. O. Rudin, J. U. Casby,Science 1957,126, 831.
U. Oesch, D. Ammann, W. Simon,Clin. Chem. 1986,32, 1448.
Author information
Authors and Affiliations
Additional information
On leave from Hitachi Ltd., Central Research Laboratory, Kokubunji, Tokyo 185, Japan.
Rights and permissions
About this article
Cite this article
Maruizumi, T., Wegmann, D., Suter, G. et al. Neutral carrier-based Na+-selective electrode for application in blood serum. Mikrochim Acta 88, 331–336 (1986). https://doi.org/10.1007/BF01206726
Received:
Revised:
Issue Date: