Rapid-scanning electrochemical detector with micro working electrode for micro high-performance liquid chromatography

  • Orginals
  • Published:
Chromatographia Aims and scope Submit manuscript

Summary

A voltammetric system controlled by a personal computer was developed using a PC-8801 mk II computer (NEC, Tokyo, Japan) for rapid-scanning voltammetry. The system was combined with an ultra-small-volume electrolytic cell with a single-carbon-fiber (7-μm diameter and 3-mm length) working electrode and used as a new detector for micro high-performance liquid chromatography. The system's capability for the detection of catecholamines and their related compounds was investigated. Three-dimensional voltamo-chromatograms were obtained by adding the potential axis of the electrode to the conventional current and time axes, leading to a dramatic improvement in the identification of each chroamtographic peak.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Y. Hirata, P. T. Lin, M. Novotny, R. M. Wightman, J. Chromatogr.,181, 287–294 (1980).

    CAS  Google Scholar 

  2. M. Goto, Y. Koyanagi, D. Ishii, J. Chromatogr.,208, 261–268 (1981).

    Article  CAS  Google Scholar 

  3. L. A. Knecht, E. J. Guthrie, J. W. Jorgenson, Anal. Chem.,56, 479–482 (1984).

    Article  CAS  Google Scholar 

  4. M. Goto, K. Shimada, T. Takeuchi, D. Ishii, Proceedings of the Seventh International Symposium on Capillary Chromatography, p. 878–885 (1986).

  5. M. Goto, T. Nakamura, D. Ishii, J. Chromatogr.,226, 33–42 (1981).

    CAS  Google Scholar 

  6. M. Goto, E. Sakurai, D. Ishii, J. Chromatogr.,238, 357–366 (1982).

    Article  CAS  Google Scholar 

  7. M. Goto, Z. Gongwei, D. Ishii, J. Chromatogr.,275, 271–281 (1981).

    Google Scholar 

  8. R. L. St. Claire III, J. W. Jorgenson, Chromatogr. Sci.,23, 186–191 (1985).

    Google Scholar 

  9. R. Samuelsson, J. O'Dea, J. Osteryoung, Anal. Chem.,52, 2215–2216 (1980).

    Article  CAS  Google Scholar 

  10. J. G. White, R. L. St. Claire III, J. W. Jorgenson, Anal. Chem.,58, 293–298 (1986).

    CAS  Google Scholar 

  11. M. Goto, D. Ishii, J. Electroanal. Chem.,102, 49–58 (1979).

    Article  CAS  Google Scholar 

  12. J. H. Christie, J. A. Turner, R. A. Osteryoung, Anal. Chem.,49, 1899–1903 (1977).

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Goto, M., Shimada, K. Rapid-scanning electrochemical detector with micro working electrode for micro high-performance liquid chromatography. Chromatographia 21, 631–634 (1986). https://doi.org/10.1007/BF02311917

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02311917

Key Words

Navigation