Summary
The purpose of this study was to develop a columnswitching HPLC method for the determination of meropenem in plasma. This method showed excellent precision and accuracy with good sensitivity and speed. The total analysis time per sample was less than 20 min and the mean coefficients of variation for intra- and inter-assay were less than 4.0%. The method has been successfully applied to plasma samples from rats receiving an intraperitoneal injection of meropenem.
Similar content being viewed by others
References
H. C. Neu, A. Novelli, N. X. Chin, Antimicrob. Agents Chemother.33, 1009 (1989).
D. E. Sentochnik, G. M. Eliopoulus, M. J. Ferraro, R. C. Moellering, Antimicrob. Agents Chemother.33, 1232 (1989).
Y. Sumita, M. Inoue, S. Mitsuhashi, Eur. J. Clin. Microbiol. Infect. Dis.8, 908 (1989).
J. R. Edwards, P. J. Turner, C. Wannop, E. S. Withnell, A. J. Grindey, K. Nairn, Antimicrob. Agents Chemother.33, 215 (1989).
Y. Sumita, Y. Eguchi, M. Fukasawa, T. Okuda, H. Yamaga, H. Matsumura, M. Sunagawa, J. Antibiot.46, 1629 (1993).
M. Fugasawa, Y. Sumita, E. T. Harabe, T. Tanio, H. Nouda, T. Kohzuki, T. Okuda, H. Matsumura, M. Sunagawa, Antimicrob. Agents Chemother.36, 1577 (1992).
R. Wise, M. Logan, M. Cooper, J. P. Ashby, J. M. Andrews, Antimicrob. Agents Chemother.34, 1515 (1990).
A. Leroy, J. P. Fillastre, F. Borsa-Lebas, I. Etienne, G. Humbert, Antimicrob. Agents Chemother.36, 2794 (1992).
M. Chimata, M. Nagase, Y. Suzuki, M. Shimomura, S. Kakuta, Antimicrob. Agents Chemother.37, 229 (1993).
R. P. Bax, W. Bastain, A. Featherstone, D. M. Wilkinson, M. Hutchison, S. J. Haworth, J. Antimicrob. Chemother.24 (suppl. A), 311 (1989).
M. P. Harrison, S. R. Moss, A. Featherstone, A. G. Fowkes, A. M. Sanders, D. E. Case, J. Antimicrob. Chemother.24 (suppl. A), 265 (1989).
L. A. Burman, I. Nilsson-Ehle, M. Hutchison, S. J. Haworth, S. R. Norrby, J. Antimicrob. Chemother.27, 219 (1991).
H. S. Lee, O. P. Zee, K. I. Kwon, J. Chromatogr.528, 425 (1990).
Y. J. Lee, H. S. Lee, Chromatographia30, 80 (1990).
H. S. Lee, H. C. Shin, S. S. Han, J. K. Rho, J. Chromatogr.574, 175 (1992).
E. S. Jung, H. S. Lee, J. K. Rho, K. I. Kwon, Chromatographia37, 618 (1993).
H. Lee, J. S. Lee, H. S. Lee, J. Chromatogr.664, 335 (1995).
Y. Takeuchi, T. Inoue, M. Sunagawa, J. Antibiot.46, 827 (1993).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Lee, H.S., Shim, H.O. & Yu, S.R. High-performance liquid chromatographic determination of meropenem in rat plasma using column-switching. Chromatographia 42, 405–408 (1996). https://doi.org/10.1007/BF02272131
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02272131