Abstract
The transition frequencies of thei-component of the R(99)15-1 and thew-component of the R(85)26-0 transition in the B-X system of molecular127I2 have been determined with an overall relative standard uncertainty of 1.3 · 10−10. For this purpose a commercial linear dye laser has been modified and stabilized to the corresponding iodine line. This dye laser serves as a transportable frequency standard which is compared with the wavelength standards of the PTB. The evaluation of an experiment for testing special relativity at the test storage ring (TSR) in Heidelberg is based on the precision of the reported interferometric wavelength comparison.
Similar content being viewed by others
References
Klein R. et al.: Z. Phys. A342, 455 (1992)
Schröder S. et al.: Phys. Rev. Lett.64, 2901 (1990)
Will C.M.: Phys. Rev. D45, 403 (1992)
Kretzschmar M.: Z Phys. A342, 463 (1992)
Riis E. et al.: Phys. Rev. A33, 3023 (1986)
Documents concerning the New Definition of the Metre: Metrologia19, 163 (1984)
Rong H. et al.: Z. Phys. D25, 337 (1993)
Bönsch G.: Appl. Opt.22, 3414 (1983)
Bönsch G.: IEEE Trans. Instrum. Meas.34, 248 (1985)
Bönsch G. et al: PTB Mitteilungen,99, 5 (1990)
Spieweck F.: IEEE Trans. Instrum. Meas.4, 361 (1980)
Gerstenkorn S., Luc, P.: Atlas du spectre d'absorption de la molecule d'iode 14800–20000 cm−1. Laboratoire Aime-Cotton, CNRS II, 1978;
Gerstenkorn S., Luc P.: Rev. Phys. Appl.14 791 (1979)
Gerstenkorn S., Luc P.: Atlas du spectre d'absorption de la molecule d'iode 14800–20000 cm−1. Complement. Identification des transitions du systeme (B-X). Laboratoire Aime-Cotton, CNRS II, 1985
Fredin-Picard, S.: How to calculate hyperfine transitions energies. Technical Report BIPM-90/5. Bureau International des Poids et Mesures 1990
Gläser M.: Opt. Commun.54, 335 (1985);
Gläser M.: Hyperfine components of iodine for optical frequency standards. PTB-Opt-25, Braunschweig 1987
Comité International des Poids et Mesures (CIPM), 81e session 1992. Recommendation 3, p. 144
Author information
Authors and Affiliations
Additional information
The authors thank H. Darnedde for the loan of anI 2 stabilized helium-neon laser and for checking its frequency against his standard. We gratefully acknowledge fruitful discussions with F. Riehle during the experiment.
Rights and permissions
About this article
Cite this article
Grieser, R., Bönsch, G., Dickopf, S. et al. Precision measurement of two iodine lines at 585 nm and 549 nm. Z. Physik A - Hadrons and Nuclei 348, 147–150 (1994). https://doi.org/10.1007/BF01289603
Received:
Revised:
Issue Date:
DOI: https://doi.org/10.1007/BF01289603