The radioactive microsphere method for the assessment of regional myocardial blood flow after coronary artery occlusion

Inaccuracies due to variations in the diameter distribution of the spheres

  • Published:
Pflügers Archiv Aims and scope Submit manuscript

Summary

In this study, we have tried to determine the magnitude of the inaccuracy of the radioactive microsphere method — due to variations in the diameter distribution of the spheres — for measuring regional myocardial blood flow after coronary artery occlusion. In 5 mongrel dogs, three types of 15 μm microsperes, labelled with125I,141Ce or85Sr, were injected simultaneously after the descending branch of the left coronary artery had been ligated. Myocardial samples were taken from the left ventricle and divided into four groups according to the number of spheres per sample. The radioactivity of the various isotopes per gram tissue was expressed as percentage of their activity per milliliter of the reference sample. The diameter distribution of microspheres, labelled with each of the isotopes, was determined light-microscopically in suspensions belonging to three different batches.

The relative error, as determined from the difference in relative radioactivity of the various types of microspheres in the tissue samples, was higher than the theoretical error for each of the number of spheres per sample. It is very likely that this discrepancy is caused by the differences in diameter distribution of the various types of microspheres, resulting in non-random error. The smaller spheres tended to go to low flow areas and the larger ones to high flow areas. Because of the non-randomness, the error due to diameter variations in the spheres can be diminished by randomizing the order of injection of the various isotopes.

The present study indicates that the relatively high degree of accuracy of the microsphere method for the determination of blood flow to large parts of the myocardium with an unimpeded coronary circulation, as was described in literature, cannot be extrapolated to the determination of regional myocardial blood flow after coronary artery occlusion, when the combination of small tissue samples, variations in the diameter distribution of the spheres and an unevenly distributed myocardial blood flow unfavourably affect the accuracy of the method.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Becker, L. C., Ferreira, R., Thomas, M.: Mapping of left ventricular blood flow with radioactive microspheres in experimental coronary artery occlusion. Cardiovasc. Res.7, 391–400 (1973)

    Google Scholar 

  2. Buckberg, G. D., Fixler, D. E., Archie, J. P., Hoffman, J. I. E.: Experimental subendocardial ischemia in dogs with normal coronary arteries. Circulat. Res.30, 67–81 (1972)

    Google Scholar 

  3. Buckberg, G. D., Luck, J. C., Payne, D. B., Hoffman, J. I. E., Archie, J. P., Fixler, D. E.: Some sources of error in measuring regional blood flow with radioactive microspheres. J. appl. Physiol.31, 598–604 (1971)

    Google Scholar 

  4. Domenech, R. J.: Total and regional coronary blood flow during acute coronary occlusion in anesthetized and conscious dogs. Cardiovasc. Res.8, 415–422 (1974)

    Google Scholar 

  5. Domenech, R. J., Hoffman, J. I. E., Noble, M. I. M., Saunders, K. B., Henson, J. R., Subijanto, S.: Total and regional coronary blood flow measured by radioactive microspheres in conscious and anaesthetized dogs. Circulat. Res.25, 581–596 (1969)

    Google Scholar 

  6. Flameng, W., Schaper, W., Lewi, P.: Multiple experimental coronary occlusion without infarction. Effects of heart rate and vasodilation. Amer. Heart J.85, 767–776 (1973)

    Google Scholar 

  7. Hoffbrand, B. I., Forsyth, R. P.: Validity studies of the radioactive microsphere method for the study of the distribution of cardiac output, organ blood flow, and resistance in the conscious rhesus monkey. Cardiovasc. Res.3, 426–432 (1969)

    Google Scholar 

  8. Marsboom, R. A., Verstraete, D., Thienpont, D., Mattheeuws, D.: The use of haloanisone and fentanyl for neuroleptanalgesia in dogs. Brit. vet. J.120, 466–468 (1964)

    Google Scholar 

  9. Phibbs, R. H., Dong, L.: Nonuniform distribution of microspheres in blood flowing through a medium-size artery. Canad. J. physiol. Pharmacol.48, 415–421 (1970)

    Google Scholar 

  10. Reneman, R. S., Wellens, D., Jageneau, A. H. M., Stynen, L.: Vertebral and carotid blood distribution in the brain of the dog and the cat. Cardiovasc. Res.8, 65–72 (1974)

    Google Scholar 

  11. Rudolph, A. M., Heymann, M. A.: The circulation of the fetus in utero. Methods for studying distribution of blood flow, cardiac output and organ blood flow. Circulat. Res.21, 163–184 (1967)

    Google Scholar 

  12. Schaper, W., Lewi, P., Flameng, W., Gijpen, L.: Myocardial steal produced by coronary vasodilation in chronic coronary artery occlusion. Basic Res. Cardiol.68, 3–20 (1973)

    Google Scholar 

  13. Schaper, W. K. A., Lewi, P., Jageneau, A. H. M.: The determinants of the rate of change of the left ventricular pressure (dP/dt). Arch. Kreisl.-Forsch.46, 17–41 (1965)

    Google Scholar 

  14. Utley, J., Carlson, E. L., Hoffman, J. I. E., Martinez, H. H., Buckberg, G. D.: Total and regional myocardial blood flow measurements with 25 μ, 15 μ, 9 μ and filtered 1–10 μ diameter microspheres and antipyrine in dogs and sheep. Circulat. Res.34, 391–405 (1974)

    Google Scholar 

  15. Yipintsoi, T., Dobbs, Jr., W. A., Scanlon, P. D., Knopp, T. J., Bassingthweights, J. B.: Regional distribution of diffusible tracers and carbonized microsphere, in the left ventricle of isolated dog hearts. Circulat. Res.33, 573–587 (1973)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Supported by I. W. O. N. L.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Reneman, R.S., Jageneau, A.H.M., van Gerven, W. et al. The radioactive microsphere method for the assessment of regional myocardial blood flow after coronary artery occlusion. Pflugers Arch. 353, 337–347 (1975). https://doi.org/10.1007/BF00587030

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00587030

Key words

Navigation