Summary
In this study, we have tried to determine the magnitude of the inaccuracy of the radioactive microsphere method — due to variations in the diameter distribution of the spheres — for measuring regional myocardial blood flow after coronary artery occlusion. In 5 mongrel dogs, three types of 15 μm microsperes, labelled with125I,141Ce or85Sr, were injected simultaneously after the descending branch of the left coronary artery had been ligated. Myocardial samples were taken from the left ventricle and divided into four groups according to the number of spheres per sample. The radioactivity of the various isotopes per gram tissue was expressed as percentage of their activity per milliliter of the reference sample. The diameter distribution of microspheres, labelled with each of the isotopes, was determined light-microscopically in suspensions belonging to three different batches.
The relative error, as determined from the difference in relative radioactivity of the various types of microspheres in the tissue samples, was higher than the theoretical error for each of the number of spheres per sample. It is very likely that this discrepancy is caused by the differences in diameter distribution of the various types of microspheres, resulting in non-random error. The smaller spheres tended to go to low flow areas and the larger ones to high flow areas. Because of the non-randomness, the error due to diameter variations in the spheres can be diminished by randomizing the order of injection of the various isotopes.
The present study indicates that the relatively high degree of accuracy of the microsphere method for the determination of blood flow to large parts of the myocardium with an unimpeded coronary circulation, as was described in literature, cannot be extrapolated to the determination of regional myocardial blood flow after coronary artery occlusion, when the combination of small tissue samples, variations in the diameter distribution of the spheres and an unevenly distributed myocardial blood flow unfavourably affect the accuracy of the method.
Similar content being viewed by others
References
Becker, L. C., Ferreira, R., Thomas, M.: Mapping of left ventricular blood flow with radioactive microspheres in experimental coronary artery occlusion. Cardiovasc. Res.7, 391–400 (1973)
Buckberg, G. D., Fixler, D. E., Archie, J. P., Hoffman, J. I. E.: Experimental subendocardial ischemia in dogs with normal coronary arteries. Circulat. Res.30, 67–81 (1972)
Buckberg, G. D., Luck, J. C., Payne, D. B., Hoffman, J. I. E., Archie, J. P., Fixler, D. E.: Some sources of error in measuring regional blood flow with radioactive microspheres. J. appl. Physiol.31, 598–604 (1971)
Domenech, R. J.: Total and regional coronary blood flow during acute coronary occlusion in anesthetized and conscious dogs. Cardiovasc. Res.8, 415–422 (1974)
Domenech, R. J., Hoffman, J. I. E., Noble, M. I. M., Saunders, K. B., Henson, J. R., Subijanto, S.: Total and regional coronary blood flow measured by radioactive microspheres in conscious and anaesthetized dogs. Circulat. Res.25, 581–596 (1969)
Flameng, W., Schaper, W., Lewi, P.: Multiple experimental coronary occlusion without infarction. Effects of heart rate and vasodilation. Amer. Heart J.85, 767–776 (1973)
Hoffbrand, B. I., Forsyth, R. P.: Validity studies of the radioactive microsphere method for the study of the distribution of cardiac output, organ blood flow, and resistance in the conscious rhesus monkey. Cardiovasc. Res.3, 426–432 (1969)
Marsboom, R. A., Verstraete, D., Thienpont, D., Mattheeuws, D.: The use of haloanisone and fentanyl for neuroleptanalgesia in dogs. Brit. vet. J.120, 466–468 (1964)
Phibbs, R. H., Dong, L.: Nonuniform distribution of microspheres in blood flowing through a medium-size artery. Canad. J. physiol. Pharmacol.48, 415–421 (1970)
Reneman, R. S., Wellens, D., Jageneau, A. H. M., Stynen, L.: Vertebral and carotid blood distribution in the brain of the dog and the cat. Cardiovasc. Res.8, 65–72 (1974)
Rudolph, A. M., Heymann, M. A.: The circulation of the fetus in utero. Methods for studying distribution of blood flow, cardiac output and organ blood flow. Circulat. Res.21, 163–184 (1967)
Schaper, W., Lewi, P., Flameng, W., Gijpen, L.: Myocardial steal produced by coronary vasodilation in chronic coronary artery occlusion. Basic Res. Cardiol.68, 3–20 (1973)
Schaper, W. K. A., Lewi, P., Jageneau, A. H. M.: The determinants of the rate of change of the left ventricular pressure (dP/dt). Arch. Kreisl.-Forsch.46, 17–41 (1965)
Utley, J., Carlson, E. L., Hoffman, J. I. E., Martinez, H. H., Buckberg, G. D.: Total and regional myocardial blood flow measurements with 25 μ, 15 μ, 9 μ and filtered 1–10 μ diameter microspheres and antipyrine in dogs and sheep. Circulat. Res.34, 391–405 (1974)
Yipintsoi, T., Dobbs, Jr., W. A., Scanlon, P. D., Knopp, T. J., Bassingthweights, J. B.: Regional distribution of diffusible tracers and carbonized microsphere, in the left ventricle of isolated dog hearts. Circulat. Res.33, 573–587 (1973)
Author information
Authors and Affiliations
Additional information
Supported by I. W. O. N. L.
Rights and permissions
About this article
Cite this article
Reneman, R.S., Jageneau, A.H.M., van Gerven, W. et al. The radioactive microsphere method for the assessment of regional myocardial blood flow after coronary artery occlusion. Pflugers Arch. 353, 337–347 (1975). https://doi.org/10.1007/BF00587030
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00587030