The contraction fraction (CF) in myocardial studies with Technetium-99m-isonitril (MIBI) — correlations with radionuclide ventriculography and infarct size measured by SPECT

  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

Criteria for the detection of coronary artery disease in nuclear cardiology include visualization of perfusion defects and functional impairment of contraction. The purpose of this study is to combine both methods in one procedure with the new myocardial perfusion tracer, 99mTc-methoxy-isobutyl-isonitril (MIBI), reducing time and radiation burden to the patient. Following an uncomplicated recovery, ten patients with first myocardial infarction participated in this study. Radionuclide ventriculography (RNV) was performed at rest and during exercise. Within 2–3 days, 370 MBq 99mTc-MIBI were injected and SPECT acquisition commenced 1 h later. Data processing included a scar image in polar coordinates. Areas of significantly reduced tracer uptake were expressed as a percentage of the total myocardial area. Directly following SPECT, resting and maximum exercise gated planar LAO images were recorded and the contraction was quantified. The concept of the contraction fraction (CF) rested on the end systolic change in count distribution: their increase in density and their centripetal concentration. For comparison, geometrical inner edge detection techniques were also applied. All algorithms for describing an EF equivalent were verified by computer simulations, showing a perfect correlation over a wide range of preset EFs. When applied to the patient studies only the non geometric methods revealed a good correlation with the ejection fraction (EF) obtained by RNV, and with the infarct size measured by SPECT. The corresponding correlation coefficients (r), standard errors (SEE) and the regression lines read as follows (in %): CF=0.56×EF+24.8; r=0.87; SEE=4.98; CF=-0.53×SPECT+71.5; r=0.93; SEE=4.19. Thus, estimation of the left ventricular function by the above defined CF is feasible, easy to perform and clinically meaningful. In one procedure with 99mTc-labelled MIBI not only the perfusion abnormalities were detectable, but also any reduction in function by a valied EF equivalent. Although the monochromatic gamma spectrum of the radionuclide provided better tissue penetrating power, the inner edge of the left ventricle was poorly outlined (especially in the stress studies) and does not lend itself to clinical routine practice.

This is a preview of subscription content, log in via an institution to check access.

Access this article

We’re sorry, something doesn't seem to be working properly.

Please try refreshing the page. If that doesn't work, please contact support so we can address the problem.

Similar content being viewed by others

References

  • Adam WE, Clausen M, Hellwig D, Henze E, Bitter F (1988) Radionuclide ventriculography (equilibrium gated blood pool scanning) — its present clinial position and recent developments. Eur J Nucl Med 13:637–647

    Google Scholar 

  • Becker LC, Silverman KJ, Bulkley BH, Kallman CH, Mellits ED, Weisfeldt M (1983) Comparison of early Thallium-201 scintigraphy and gated blood pool imaging for predicting mortality in patients with acute myocardial infarction. Circulation 67:1272–1282

    Google Scholar 

  • Bauer R, Busch U, Gebhardt U, Lutilsky L, Renner U, Blömer H, Pabst HW (1988) Erste Ergebnisse der Myokardszintigraphie mit einem Tc-99m-markierten Isonitril. Z Kardiol [Suppl] 77, 1:11

    Google Scholar 

  • Caldwell JH, Hamilton GW, Sorensen SG, Ritchie JL, Williams DL, Kennedy JW (1980) The detection of coronary artery disease with radionuclide techniques: A comparison of rest-exercise Thallium imaging and ejection fraction response. Circulation 61:610–619

    Google Scholar 

  • Clausen M, Weller R, Henze E, Bitter F, Adam WE (1988) Differenzierende Darstellung und Quantifizierung der Myokardnarbe und der Belastungsischämie in Polarkoordinaten für die Myokard-ECT. Klinische und technische Aspekte. Nucl Compact 19:50–52

    Google Scholar 

  • Dudczak R, Leitha T, Kletter K, Angelberger P, Schmoliner R (1988) Comparison of Tc-99m-methoxypropyl-isonitril (MPIN) and Tc-99m-methoxyisobutyl-isonitril (MIBI) for myocardial imaging in man. J Nucl Med 29:794

    Google Scholar 

  • Geffers H, Sigel H, Bitter F, Kampmann H, Stauch M, Adam WE (1976) Untersuchungen der segmentalen Wandbewegung des linken Ventrikels bei Herzgesunden und Myokardinfarktpatienten mit einer katheterlosen nuklearmedizinischen Methode (Kamera-Kinematographie des Herzens). Z Kardiol 65:680–692

    Google Scholar 

  • Grenz R, Maul FD, Standke R, Klepzig H, Kober G, Hör G (1986) Ergebnisse der kombinierten Myokardszintigraphie und Radionuklidventrikulographie vor und nach transluminaler Koronarangioplastik kritischer Koronararterienstenosen. Nukl Med 25:106–113

    Google Scholar 

  • Grodzinski E, Fentrop T, Scarf-Bornhofen, E, Keller T, Bierck G, Borer JS, Schoop W, Blümchen G (1985) Bedeutung der Auswurffraktion (EF) in Ruhe und bei Belastung mit Hilfe der Radionuklidventrikulographie (RNVA) für die Prognose von Herzinfarktpatienten — Vergleich mit anderen Untersuchungsmethoden. Z Kardiol 74:525–530

    Google Scholar 

  • Handler CE, Ardley RG, Maisey MN (1985) Gated Thallium tomography — potential for improved accuracy in the detection of coronary artery disease. Br J Rad 58:107–110

    Google Scholar 

  • Henze E, Tymiec A, Delagardelle C, Adam WE, Bitter F, Stauch M (1986) Specification of regional wall motion abnormalities by phase analysis of radionuclide angiograms in coronary artery disease and non-coronary artery disease patients. J Nucl Med 27:781–787

    Google Scholar 

  • Hoffmeister HM, Kaiser W, Hanke H, Müller-Schauenburg W, Karsch KR, Feine U, Seipel L (1985) Erkennung, Quantifizierung und Lokalisation von Myokardinfarkten: Vergleich der Thallium-Single-Photon-Emissions-Computertomography mit biplaner Angiographie. Z Kardiol 74:625–632

    Google Scholar 

  • Klepzig Jr H, Kaltenbach M (1987) Wann ist die Durchführung einer Thallium-201-Myokardszintigraphie indiziert? — Die Sicht des klinisch tätigen Kardiologen. Nucl Med 26:232–233

    Google Scholar 

  • Knesewitsch P, Fritsch S, Kleinhans E, Büll Udalrich (1987) Combined evaluation of first pass radionuclide angiography and equilibrium radionuclide ventriculography in the diagnosis of coronary artery disease. Eur J Nucl Med 12:598–601

    Google Scholar 

  • Lichtlen PA (1988) Cardiac nuclear medicine, present status, future hopes as seen from the view of a cardiologist. Eur J Nucl Med 13:606–611

    Google Scholar 

  • McKillop JH, Fawcett HD, Baumert JE, McDougall IR, DeBusk RF, Harrison DC, Goris ML (1981) ECG gating of Thallium-201 myocardial images: Effect on detection of ischemic heart disease. J Nucl Med 22:219–225

    Google Scholar 

  • Okada RD, Glover D, Gaffney T, Williams S (1988) Myocardial kinetics of technetium-99m-hexakis-2-methoxy-2-methylropylisonitril. Circulation 77:491–498

    Google Scholar 

  • Ritchie JL, Davis KB, Williams DL, Caldwell J, Kennedy JW (1984) Global and regional left ventricular function and tomographic radionuclide perfusion: The Western Washington intracoronary streptokinase in myocardial infarction trial. Circulation 70:867–875

    Google Scholar 

  • Sporn V, Balino NP, Holman BL, Liprandi AS, Masoli O, Mitta A, Camin LL, Castiglia S, McKusick KA (1988) Simultaneous measurement of ventricular function and myocardial perfusion using the Technetium-99m isonitriles. Clin Nucl Med 13:77–81

    Google Scholar 

  • Stirner H, Buell U, Kleinhans E, Bares R, Grosse W (1988) Myocardial kinetics of Tc-99m hexakis-(2-methoxy-isobutyl-isonitril (HMIBI) in patients with coronary heart disease: A comparative study versus Tl-201 with SPECT. Nucl Med Commun 9:15–23

    Google Scholar 

  • Taillefer R, Laflamme L, Dupras G, Picard M, Phaneuf DC, Leveille J (1988) Myocardial perfusion imaging with Tc99m-methoxy-isobutyl-isonitril (MIBI): Comparison of short and long time intervals between rest and stress injections. Preliminary results. Eur J Nucl Med 13:515–522

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Supported in part by the grant LFS28 from the ministry of science, Stuttgart, Federal Republic of Germany

Rights and permissions

Reprints and permissions

About this article

Cite this article

Clausen, M., Henze, E., Schmidt, A. et al. The contraction fraction (CF) in myocardial studies with Technetium-99m-isonitril (MIBI) — correlations with radionuclide ventriculography and infarct size measured by SPECT. Eur J Nucl Med 15, 661–664 (1989). https://doi.org/10.1007/BF00251680

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00251680

Key words

Navigation