Abstract
Labeled IgG was evaluated versus labeled albumin for measurement of plasma volume, to see whether it would give a smaller initial dilution volume (indicating a smaller premixing extravascular loss of label) and a smaller difference between initial dilution volume and dilution volume at time 10 min (indicating a negligible extravascular loss in the first 10 min after mixing). IgG was found to have a lower transcapillary escape rate than albumin (P<0.01) in eight normal volunteers and in eight hypertensive subjects, hypertension being associated with an increased transcapillary escape of both proteins. Despite this, the dilution volumes obtained were indistinguishable and the need for a correction through a retropolation procedure was the same with both proteins. Albumin and IgG dilution volumes were highly correlated in 21 subjects (r=0.977) so that use of labeled IgG is a proper alternative to use of labeled albumin for plasma volume determination. However, since IgG brings no consistent advantage, labeled albumin remains the best available tracer for that purpose.
Similar content being viewed by others
References
Andersen, S.B.: Simultaneous determination of plasma volume with 131I-labelled gamma-globulin, 131I-labelled albumin and T-1824. Clin. Sci. 23, 221–228 (1962)
International Committee for Standardization in Hematology: Standard techniques for the measurement of red-cell and plasma volume. Br. J. Haematol. 25, 801–814 (1973)
Lawson, H.C.: The volume of blood — a critical examination of methods for its measurement. In: Handbook of physiology, (W.F. Hamilton and P. Dow, eds.) Section, II, Volume I, pp. 23–49. Washington: American physiological Society 1962
Parving, H.H., Gyntelberg, F.: Transcapillary escape rate of albumin and plasma volume in essential hypertension. Circ. Res. 32, 643–651 (1973)
Rodnan, G.P.: Simultaneous estimation of plasma volume with Evans blue dye and I131 labelled globulin. Clin. Res. Proc. 4, 90 (1956)
Schultze, H.E., Heremans, J.F.: In: Molecular biology of human proteins. Volume I, pp 176–181. Amsterdam: Elsevier 1973
Steinbuch, M., Audran, R., Amouch, P., Blatrix, C.: The preparation of gammaglobulin for intravenous use in Paris. Vox. Sang. 13, 103–106 (1967)
Steinfeld, J.C., Greene, F.E., Tabern, D.C., Paton, R.R., Flick, A.L.: Degradation of iodinated human serum albumin prepared by various procedures. J. Lab. Clin. Med. 51, 756–765 (1958)
Walker, W.G., Ross, R.S., Hammond, J.D.S.: Study of the relationship between plasma volume and transcapillary protein exchange using I131-labeled albumin and I125-labeled globulin. Circ. Res. 8, 1028–1040 (1960)
Wochner, R.D., Adatepe, M., Van Amburg, A., Potchen, E.J.: A new method for estimation of plasma volume with the use of the distribution space of indium-113 m-transferrin. J. Lab. Clin. Med. 75, 711–720 (1970)
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Plouin, P.F., Degoulet, P., Menard, D. et al. IgG versus albumin for measurement of plasma volume in normal and hypertensive men. Eur J Nucl Med 3, 183–186 (1978). https://doi.org/10.1007/BF00256641
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00256641