Skip to main content
Log in

The efficiency of protective gloves used in the handling of cytotoxic drugs

  • Original Articles
  • Handing of Cytotoxic Drugs, Protective Gloves
  • Published:
Cancer Chemotherapy and Pharmacology Aims and scope Submit manuscript

Summary

A range of clinical and industrial gloves have been evaluated to determine their ability to exclude penetration by cytotoxic drugs.

Radiolabelled cyclophosphamide, methotrexate, daunomycin, cytosine arabinoside, and vincristine sulphate were studied in an equilibrium dialysis system in which the glove material was used as the dialysis membrane.

The thicker gloves were the most effective, but very little drug crossed any of the gloves tested under laboratory conditions. Further studies to evaluate gloves in conditions of clinical use are now needed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Anderson RW, Puckett WH, Dana WJ, Nguyen TV, Theiss JC, Matney TS (1982) Risk of handling injectable anti-neoplastic agents. Am J Hosp Pharmacy 39: 1881–1887

    Google Scholar 

  2. Falck K, Grohn P, Sorsa M, Vainio M, Hemonen E, Holsti LR (1979) Mutagenicity in urine of nurses handling cytotoxic drugs. Lancet 1: 1250–1251

    Google Scholar 

  3. Knowles RS, Virden JE (1980) Handling of injectable antineoplastic agents. Br Med J 281: 589

    Google Scholar 

  4. Lerner HJ (1978) Acute myelogenous keukaemia in patients receiving chlorambucil as long-term adjuvant chemotherapy for stage II breast cancer. Cancer Treat Rep 62: 1135–1138

    Google Scholar 

  5. Schilsky RL, Erlichman C (1982) Late complications of chemotherapy: Infertility and carcinogenesis. In: Chabner B (ed) Pharmacological principles of cancer treatment. Saunders, Philadelphia London Toronto, pp 109–131

    Google Scholar 

  6. Thomson K, Mikkelsen HI (1975) Protective capacity of gloves used for handling of nitrogen mustard. Contact Dermatitis 1: 268–269

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Slevin, M.L., Ang, L.M., Johnston, A. et al. The efficiency of protective gloves used in the handling of cytotoxic drugs. Cancer Chemother. Pharmacol. 12, 151–153 (1984). https://doi.org/10.1007/BF00256536

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00256536

Keywords

Navigation