Abstract

Magnetic resonance imaging of the eye usually includes T2-weighted images both for screening purposes and for characterization of melanoma. Conventional T2-weighted spin-echo (SE) imaging suffers both from long acquisition times and incomplete recovery of the vitreous' signal. A fast SE sequence was therefore compared prospectively with conventional sequences in 29 consecutive patients with lesions of the eye. Fast SE images delineated melanoma and other lesions of the eye from vitreous better than conventional T2-weighted images. Image quality and lesion conspicuity were improved on the fast sequence. Whereas melanoma appeared hypointense to vitreous on both types of images, subretinal effusion was hypointense on fast images and hyperintense on conventional T2-weighted images. Ghosting of the globe, which, however, did not decrease diagnostic value, was more pronounced on fast images. Conventional T2-weighted images may be replaced by fast SE images in MR studies of the eye with a gain in lesion conspicuity and significant time saving.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Mafee MF, Peyman GA, Grisolano JE, Fletcher ME, Spigos DG, Wehrli FW, Rasouli F, Capek V (1986) Malignant uveal melanoma and simulating lesions: MR imaging evaluation. Radiology 160: 773.

    Google Scholar 

  2. Mafee MF, Lindner B, Peyman GA, Langer BG, Choi KH, Camek V (1988) Choroidal hematoma and effusion: evaluation with MR imaging. Radiology 168: 781.

    Google Scholar 

  3. Wilms G, Marchal G, Van Fraeyenhoven L, Demaerel P, Baert AL, Dralands G (1991) Shortcomings and pitfalls of ocular MRI. Neuroradiology 33: 320.

    Google Scholar 

  4. Mafee MF, Peyman GA, Peace JH, Cohen SB, Mitchell MW (1987) Magnetic resonance imaging in the evaluation and differentiation of uveal melanoma. Opthalmology 94: 341.

    Google Scholar 

  5. Jones KM, Mulkern RV, Mantello MT, Melki PS, Ahn SS, Barnes PD, Jolesz FA (1992) Brain hemorrhage: evaluation with fast spin-echo and conventional dual spin-echo images. Radiology 182: 53.

    Google Scholar 

  6. Norbash AM, GH Glover, DR Enzman (1992) Intracerebral lesion contrast with spin-echo and fast spin-echo sequences. Radiology 185: 661.

    Google Scholar 

  7. Sze G, Merriam M, Oshio K, Jolesz FA (1992) Fast spin-echo imaging in the evaluation of intradural disease. Am J Neuroradiol 13: 1383.

    Google Scholar 

  8. Hawnaur JM, Hutchinson CE, Isherwood I (1994) Clinical evaluation of fast spin-echo sequences for cranial magnetic resonance imaging at 0.5 Tesla. Br J Radiol 67: 423.

    Google Scholar 

  9. Jack CA, Krecke KN, Luetmer PH, Cascino GD, Sharborugh FW, O'Brien PC, Parisi JE (1994) Diagnosis of medial temporal lobe sclerosis with conventional versus fast spin-echo MR imaging. Radiology 192: 123.

    Google Scholar 

  10. Kaufman L, Kramer DM, Crooks LE, Ortendahl DA (1989) Measuring signal-to-noise ratios in MR imaging. Radiology 173: 265.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Correspondence to: N. Hosten

This work was supported by grant 70-01847-Ho 1, Deutsche Krebshilfe.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hosten, N., Lemke, A.J., Bornfeld, N. et al. Fast spin-echo MR imaging of the eye. Eur. Radiol. 6, 900–903 (1996). https://doi.org/10.1007/BF00240700

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00240700

Key words

Navigation