Skip to main content
Log in

Analysis of spermatozoa movement using a video imaging technique

  • Original Paper
  • Published:
Histochemistry and Cell Biology Aims and scope Submit manuscript

Abstract

The aim of this paper is to present methods for a fully computerised analysis of spermatocyte movement. The technique were designed for processing pure images of spermatozoa captured from a light microscope. The techniques described allowed for the reduction of background light inhomogeneity and for the correct detection of moving cells and involved densitometric equalisation of background inhomogeneity and implementation of the dynamic threshold, adopted for the recognition of objects. The method for relating cells (found in each frame processed) to movement trajectories use heuristic rules, describing the behaviour of moving cells. This permitted samples containing high numbers of spermatocytes within the observed area to be processed with maximum accuracy.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Aanesen A, Benvold E (1989) The Cellsoft computerized semen analysis system I. Consistency of measurements and stability of results in relation to sample size analyzed. Andrologia 21:559–567

    Article  PubMed  CAS  Google Scholar 

  • Armant DR, Ellis MA (1995) Improved accuracy of sperm motility assessment using a modified Micro-Cell sperm counting chamber. Fertil Steril 63:1127–1130

    Google Scholar 

  • Benvold E, Aanesen A (1990) The Cellsoft computerized semen analysis system II. On the optimalization of running conditions concerning gray scale and cell size range. Andrologia 22:43–54

    Google Scholar 

  • Cimino C, Benigno M, Cassara G, Bajamonte M, Mangione D, Catalano G, Cittadini E (1994) Computer assisted assessment of the variations of sperm kinetics after semen treatment with Pellet Swim-up (Psu), and with centrifugation on a discontinuous Percoll gradient at reduced volumes (mini-CDPG). Acta Eur Fertil 25:283–289

    PubMed  CAS  Google Scholar 

  • Crittenden JA, Handelsman DJ (1995) Density adjustment of software settings minimizes bias in automated sperm motility estimation. Hum Reprod 10:607–612

    PubMed  CAS  Google Scholar 

  • Davis RO, Obasaju MF, Andrew JB, Katz DF (1989) Effects of dilution with homologous seminal plasma (HSP) and phosphate-buffered saline (PBS) on computer aided sperm analysis (CASA) measures of human seminal sperm motion. Fertil Steril 45:65

    Google Scholar 

  • Davis RO, Boyers SP (1992) The role of digital image analysis in reproductive biology and medicine. Arch Pathol Lab Med 116:351–363

    PubMed  CAS  Google Scholar 

  • Holt W, Watson P, Curry M, Holt C (1994) Reproducibility of computer aided semen analysis: comparison of five different systems. Fertil Steril 62:1277–1282

    PubMed  CAS  Google Scholar 

  • Hurowitz EH, Leung A, Wang C (1995) Evaluation of the Cell-Trak computer-assisted sperm analysis in comparison to the CellSoft system to measure human sperm hyperactivation. Fertil Steril 64:427–432

    PubMed  CAS  Google Scholar 

  • Irvine DS, MacLeod IC, Tempelton AA, Masterton A, Taylor A (1994) A prospective clinical study of the relationship between the computer assisted assessment of human semen quality and the achievement of pregnancy in vivo. Hum Reprod 9:2324–2334

    PubMed  CAS  Google Scholar 

  • MacLeod IC, Irvine DS (1995) The predictive value of computer assisted semen analysis in the context of a donor insemination programme. Hum Reprod 10:580–586

    PubMed  CAS  Google Scholar 

  • MacLeod IC, Irvine DS, Masterton A, Taylor A, Tempelton AA (1994) Assessment of the conventional criteria of semen quality by computer assisted image analysis: evaluation of the Hamilton-Thorn motility analyser in context of service andrology laboratory. Hum Reprod 9:310–319

    PubMed  CAS  Google Scholar 

  • Mak C, Kooij RJ van, Eimers JM, Velde ER te (1994) Human sperm movement assessed with Hamilton-Thorn motility analyzer and in vitro fertilization. Andrologia 26:323–329

    Article  PubMed  CAS  Google Scholar 

  • Martin CI, Calamera JC, Rovasio RA (1995) Development of an objective, semiautomated method for assessment of sperm motility. Andrologia 27:115–119

    Article  Google Scholar 

  • Mazzilli F, Rossi T, Sabatini L, Dondero F (1995) Superimposed image analysis system (SIAS) software: a new approach to sperm motility assessment. Fertil Steril 64:653–656

    PubMed  CAS  Google Scholar 

  • McKinney KA, Thompson W (1994) Reproducibility of sperm motility measurements in asthenozoospermic and normozoospermic individuals using Hamilton-Thorn motility analyzer. Arch Androl 33:151–155

    PubMed  CAS  Google Scholar 

  • Mortimer ST, Swan MA (1995) Kinematics of capacitating human spermatozoa analysed at 60 Hz. Hum Reprod 10:873–879

    PubMed  CAS  Google Scholar 

  • Moses DF, Heras MA de las, Valcarcel A, Perez L, Baldassarre H (1995) Use of computerized motility analyser for the evaluation of frozen-thawed ram spermatozoa. Andrologia 27:25–29

    Article  PubMed  CAS  Google Scholar 

  • Swanson ML, Collins JM, Freiman SF, Dubin NH (1995) Effects of Percoll wash on sperm motion parameters and subsequent fertility in intrauterine insemination cycles. J Assist Reprod Genet 12:48–54

    Article  PubMed  CAS  Google Scholar 

  • Sukchareon N, Aribarg A (1995) Evaluation of the Hamilton-Thorn motility analyzer for routine semen analysis. J Med Assoc Thai 78:182–190

    Google Scholar 

  • Terriou P, Giorgetti C, Auquier P, Hans E, Spach JL, Salzmann J, Roulier R (1994) Comparison of optical analysis and computerized analysis of sperm movement in a program of 316 in vitro fertilization. Contracept Fertil Sex 22:418–422

    PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Warchol, W., Warchol, J.B., Filipiak, K. et al. Analysis of spermatozoa movement using a video imaging technique. Histochem Cell Biol 106, 521–526 (1996). https://doi.org/10.1007/BF02473315

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02473315

Keywords

Navigation