Skip to main content
Log in

Diffusing Fibre Tip for the Minimally Invasive Treatment of Liver Tumours by Interstitial Laser Coagulation (ILC): An Experimental Ex Vivo Study

  • Original Article
  • Published:
Lasers in Medical Science Aims and scope Submit manuscript

Abstract.

A newly developed diffusing laser applicator was examined for interstitial laser coagulation (ILC) of liver tumours. The applicator consisted of a matted quartz core and a quartz glass dome, also matted on its inner surface and sealed to the fibre. The applicator provided a homogeneous light intensity distribution over an active length of about 20 mm. Lesions were created in an ex-vivo porcine liver model using a Nd-YAG laser comparing the new diffusing tip with a Ringmode®-ITT applicator in order to find optimal laser parameters and damage thresholds. The lesions were investigated using macroscopic size measurement, volume calculation and histological examination (H&E, NADPH-dehydrogenase). The damage threshold of the diffusing tip was 6 W at 14 min exposure time whereas the Ringmode®-ITT applicator had its limit at 5 W and 12 min exposure. Comparing various exposure times showed that treatment over a time of more than 840 s did not significantly increase the lesion volume. At 5 W and 720 s the mean lesion volume was 6.9±1.1 cm3 with the diffusing tip and 6.3±0.6 cm3 with the Ringmode®-ITT applicator, both having a slight ellipsoidal shape. Hence, the created lesions were not significantly different for both applicators when the same laser parameters were applied. On the other hand, the new diffusing tip had a higher damage threshold and was therefore capable of producing maximal coagulation volumes of up to 7.9±0.5 cm3 at 5 W and 20 min. The experiments showed that lesions with a dimension of 31×22 mm can be achieved with the diffusing applicator which seem suitably sized for treating small human liver metastases in a single laser session.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Paper received 25 April 1997; accepted after revision 13 March 1998.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Germer, C., Albrecht, D., Isbert, C. et al. Diffusing Fibre Tip for the Minimally Invasive Treatment of Liver Tumours by Interstitial Laser Coagulation (ILC): An Experimental Ex Vivo Study. Lasers Med Sci 14, 32–39 (1999). https://doi.org/10.1007/s101030050018

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s101030050018

Navigation