Initial platelet adhesion and platelet shape on polymer surfaces with different carbon bonding characteristics (anin vitro study of Teflon, Pellethane and XLON intravenous cannulae)

  • Papers
  • Published:
Journal of Materials Science: Materials in Medicine Aims and scope Submit manuscript

Abstract

Two commercially available intravenous catheters (i.d. 1.2 mm), made of polytetrafluoroethylene (PTFE, Teflon) and a thermoplastic polyurethane-polytetramethylene glycol block-copolymer (TPEU, Pellethane D-65), and a catheter made of a new test material, a polyamide-polyethylene glycol block-copolymer (XLON D-60), were compared with respect to surface chemistry, platelet adhesion and platelet shape changein vitro. Surface chemistry was evaluated by X-ray photoelectron spectrosopy. High-resolution carbon peaks were obtained at 15 and 90° take-off angle. The hydrophilicity was determined by measuring capillary rise in the catheters with distilled water. Platelet adhesion and platelet shape changes on the catheter surfaces were examinedin vitro, in a system without blood-air interface, and visualized by scanning electron microscopy. The degree of hydrophilicity of the materials appeared to be related to the relative ether carbon content of their outermost surfaces. The platelet adhesion was low on hydrophilic surfaces (XLON) and increased with decreasing hydrophilicity on the more hydrophobic surfaces (TPEU and PTFE). The degree of shape change of the adhered platelets also increased with decreasing hydrophilicity. Changes in surface chemistry caused by toluene extraction of the TPEU significantly decreased platelet adhesion and the degree of shape change in parallel with an increased ether carbon content of the surface.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. N. LARSSON, K. STENBERG, L. E. LINDER and I. CURELARU,Acta Anaesthaesiol. Scand. 33 (1989) 223.

    Google Scholar 

  2. Y. MORI, S. NAGAOKA, H. TAKIUCHI, T. KIKUCHI, N. NOGUCHI, H. TANZAWA and Y. NOISHIKI,Trans. Amer. Soc. Artificial Internal Organs 28 (1982) 459.

    Google Scholar 

  3. G. I. BELL, M. DEMBO and P. BONGRAND,Biophys. J. 45 (1984) 1051.

    Google Scholar 

  4. Y. IKADA, H. IWATA, F. HORII, T. MATSUNAGA, M. TANIGUCHI and M. SUZUKI,J. Biomed. Mater. Res. 15 (1981) 697.

    Google Scholar 

  5. R. D. FALB, R. I. LEININGER and J. P. CROWLEY,Ann. NY Acad. Sci. 283 (1977) 396.

    Google Scholar 

  6. V. SA DA COSTA, D. BRIER-RUSSELL, E. W. SALTZMAN and E. W. MERILL,J. Colloid Interface Sci. 80 (1981) 445.

    Google Scholar 

  7. E. W. MERILL, E. W. SALZMAN, V. SA DA COSTA, D. BRIER-ROUSSELL, A. DINCER, P. PAPE and J. N. LINDON, in “Biomaterials: Interfacial Phenomena and Applications”, Advances in Biochemistry Series, Vol. 199, edited by S. L. Cpooper and N. A. Peppas (1981), p. 35.

  8. E. W. MERILL, E. W. SALZMAN, S. WAN, N. MAHMUD, L. KUSHNER, J. N. LINDON and J. CURME,Trans. Amer. Soc. Artificial Internal Organs 28 (1982) 482.

    Google Scholar 

  9. D. E. GREGONIS, D. E. BUERGER, R. A. VAN WAGENEN, S. K. HUNTER and J. D. ANDRADE, in Transactions of the Second World Congress on Biomaterials, presented at the Tenth Annual Meeting of the Society for Biomaterials, Washington, DC, 27 April to 1 May 1984, p. 266.

  10. P. BUSCEMI, D. BACK and R. SHERMAN, abstracts of The Thirteenth Annual Meeting of the Society for Biomaterials, New York, 2 to 6 June 1987 p. 63.

  11. L. VROMAN,Ann. NY Acad. Sci. 283 (1977) 557.

    Google Scholar 

  12. B. D. RATNER and R. W. PAYNTER, presented at the International Colloquium on Polyurethanes in Medicine, Feelbach, West Germany (27 to 29 January 1983).

  13. S. L. GOODMAN, M. D. LELAH, L. K. LAMBRECHT, S. L. COOPER and R. M. ALBRECHT,Scanning Electron Microsc. 1 (1984) 379.

    Google Scholar 

  14. ABACUS CONCEPTS INC., 512+ Stat View. Brain Power, Inc. 24009 Ventura Blvd, Suite 250, Calabasas, California 91302, USA.

  15. S. R. HANSON, L. A. HARKER, B. D. RATNER and S. A. HOFFMAN,J. Lab. Clin. Med. 95 (1980) 289.

    Google Scholar 

  16. M. D. LELAH, R. J. STAFFORD, L. K. LAMBRECHT, B. R. YOUNG and S. L. COOPER,Trans. Amer. Assoc. Artificial Internal Organs 27 (1981) 504.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Larsson, N., Linder, LE., Curelaru, I. et al. Initial platelet adhesion and platelet shape on polymer surfaces with different carbon bonding characteristics (anin vitro study of Teflon, Pellethane and XLON intravenous cannulae). J Mater Sci: Mater Med 1, 157–162 (1990). https://doi.org/10.1007/BF00700876

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00700876

Keywords

Navigation