Abstract
The specific surface area of mercuric oxide has been measured by heterogeneous isotope exchange, gas adsorption, air-permeability and microscopic methods. Values obtained by the four methods were compared and explanations given for the observed differences.
Similar content being viewed by others
References
Y.K. Rao, B.V. Acharya, B. Rangamannar,J. Radioanal. Nucl. Chem. Lett., 94 /1985/ 363.
M.H. Dye,N.Z.J. Agr. Res., 14 /1971/ 526.
Himy Albert, CFSTI. fromSci. Tech. Aerosp. Rep., 7 /1969/ 4504.
V.I. Klochkov, E.A. Bolgarova, L.Ya. Rappoport,IZV. Vyssh. Uchebu. Zaved. Khim. Khim. Technol., 21 /1978/ 1384.
Winta Chandranondnaiwinit, E. Blanche Sommers,J. Pharm. Sci., 55 /1966/ 1221.
J.D. Rascio Vicente, J.J. Caprari,J. Peintures Pigments Vernis., 45 /1969/ 102.
Civijan Simon, M. Margetis Peter, L. Reddick Robert,J. Den. Res., 48 /1969/ 536.
E.J. Poziomek,Talanta, 18 /1971/ 553.
V.N. Bakul, A.A. Shulzhenko, A.F. Get'man,Ger. Offen., 2 /1973/ 226.
F.A. Paneth, W. Vorwerk,Z. Phys. Chem., /1922/ 445.
P.H. Emmett, A.S.T.M. Symposium on New Methods for Particles Size Determination in the Sub-Sieve Range, p. 95, 1941.
P.C. Carman, P.K.R. Malherbe,J. Soc. Chem. Ind., 69 /1950/ 134.
P.C. Carman, J.C. Arnell,Can. J. Res., 26A /1948/ 129.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Rao, Y.K., Rangamannar, B. Determination of the surface area of mercuric oxide by isotope exchange and other methods. Journal of Radioanalytical and Nuclear Chemistry Letters 96, 427–433 (1985). https://doi.org/10.1007/BF02163044
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02163044