Summary
In ten patients with acute or chronic renal failure, repeated measurements of spirometrics, blood gases and intra-abdominal pressure were performed during peritoncal dialysis. The dialysis lasted 46 hours (mean) with an average exchange volume of 1.9 liter/hour. The two liter fillings caused an increase of the intra-abdominal pressure of 7.5 cm H2O (mean) as compared to empty abdomen and a decrease of the vital capacity of 12.7% (mean) (2p<0.05). One liter exchanges caused +3.2 cm H2O and −6.8%, respectively. There were no significant changes in the arterial blood gases and in the quiet breathing during the two liter fillings. Blood gases alterations before and after dialysis only showed the expected adaptation to the corrected metabolic acidosis (pCO2 increased from 35.4 Torr to 38.5 Torr and pH from 7.33 to 7.42, while base-excess changed from −7.12 to +0.25 mVal). The only pulmonary complications were, in some cases, the increase or the appearance of pleural effusions.
There is no reason to expect that a well controlled peritoneal dialysis with 2-liter cycles should notoriously impend pulmonary functions. We cannot agree with Berlyneet al. (1967) who suggest to abandon this method in favor of the 1-liter cycling.
Zusammenfassung
Bei 10 Patienten mit akutem und chronischem Nierenversagen wurden während einer im Mittel 46 Std dauernden Peritonealdialyse spirographische und blutgasanalytische Untersuchungen sowie Messungen des intraabdominellen Druckes durchgeführt. Bei Verwendung von 2 Liter Spülflüssigkeit kam es während eines Dialysecyclus regelmäßig zu einem Anstieg des intraabdominellen Druckes und zu einem geringfügigen, aber statistisch signifikanten Abfall der Vitalkapazität. Ruheatmung und arterielle Blutgase änderten sich jedoch unter der Erhöhung des intraabdominalen Volumens nicht. Insbesondere kam es während eines Dialysecyclus nicht zu einem Abfall des arteriellen Sauerstoffdruckes. Während der gesamten Dialysedauer veränderten sich die arteriellen Blutgase lediglich entsprechend der Abnahme der vorbestehenden metabolischen Acidose (pCO2-Anstieg, pH-Anstieg). An bronchopulmonalen Komplikationen wurden lediglich in einigen Fällen eine Zunahme bzw. ein Auftreten von Pleuraergüssen beobachtet. Ein Verlassen dieses Verfahrens zugunsten der weniger effektiven Dialyse mit nur 1 Liter Spülflüssigkeit erscheint nicht gerechtfertigt.
Similar content being viewed by others
Literatur
Agostini, E.: A graphical analysis of thoraco-abdominal mechanics during the breathing cycle. J. app. Physiol.16, 1055 (1961).
Angell, D., Frank, R., Gaensler, E., Radger, T.: Pulmonary function in pregnancy I. Serial observations in normal women. II. Comparison of the effects of Pneumoperitoneum. III. Serial observations in patients with pulmonary insufficiency. Amer. Rev. Tuberc.67, 568 (1953).
Auchincloss, J. H., Sipple, J., Gilbert, R.: Effect of obesity on ventilatory adjustment to exercise. J. appl. Physiol.18, 19 (1963).
Berlyne, G. M., Lee, H. A., Ralston, A. J., Wookcock, J. A.: Pulmonary complications of peritoneal dialysis. Lancet1967 I, 1339.
Boen, S. T.: Periodic peritoneal dialysis using the repeated puncture technique and an automatic cycling machine. Trans. Amer. Soc. artif. intern. Org.10, 409 (1964).
—— Peritoneal dialysis in clinical medicine. Springfield: Ch. C. Thomas 1964.
Brittinger, W. D., Strauch, M., Hupe, G., Henning, G. E. v., Huber, W., Schwarzbeck, A. M., Schütz, W.: Hämodynamische Veränderungen bei der Peritonealdialyse. Verh. dtsch. Ges. inn. Med.74, 1189 (1968).
Comroe, J. H., Forster, R. E., Dubois, A. B., Briscoe, W. A., Carlsen, E.: Die Lunge — Klinische Physiologie und Lungenfunktionsprüfung, 2te. Ed. Stuttgart: Schattauer 1968.
Daum, S., Janota, M., Bondik, F.: Pulmonary diffusin capacity in uraemica. Proc. Europ. Dial. Transpl. Ass.3, 58 (1966).
Emmrich, J.: Flüssigkeitslunge. In: Peritonealdialyse, hrsg. von F. Scheler, I, 144. München: Urban & Schwarzenberg 1967.
Fabel, H., Hamm, J.: Atemmechanik und arterielle Blutgase bei Fettsucht. Beitr. Klin. Tuberk.-krankheiten135, 298 (1967).
Gasteyer, K. H.: Die intermittierende Peritonealdialyse bei Niereninsuffizienz. Med. Welt42, 2390 (1965).
Gayrard, P., Becker, M., Bergofsky, E. H.: The effects of abdominal weights on diaphragmatic position and excursion in man. Clin. Sci.35, 589 (1968).
Gibson, P. G.: Haemodinamic factors in the development of pulmonary edema in renal failure. Lancet1966 II, 1217.
Gleichmann, K., Lübbers, D. W.: Die Messung des Sauerstoffdruckes in Gasen und Flüssigkeiten mit der PT-Elektrode unter besonderer Berücksichtigung der Messung im Blut. Pflügers Arch. ges. Physiol.271, 431 (1960).
Harrison, T. R.: Principles of internal medicine. New York: McGraw-Hill 1962.
Hartung, W., Kafarnik, H.: Zur Statik des Thorax-Lungen-Systems an der Leiche. Med. thorac. (Basel)23, 1–14 (1966);23, 77–94 (1966).
Islam, N., Ali, S., Kabir, H.: Hepatic hydrothorax. Brit. J. Dis. Chest.59, 222 (1965).
Katz, L. N.: Ist Int. Congress of Nephrology. 1958. Zit. durch: Rusznyak, I., Földi, M., Szabó, G., Lymphatics and lymph circulation. Oxford: Pergamon Press 1967.
Lasker, N., Shalhoub, R., Habibe, O., Passarotti, C.: The management of end-stage kidney disease with intermittent peritoneal-dialysis. Ann. intern. Med. 62, No 6 (1965).
Loew, P. G., Thews, G.: Die Altersabhängigkeit des arteriellen Sauerstoffdruckes bei der berufstätigen Bevölkerung. Klin. Wschr.40, 1093 (1962).
Mead, J., Milic-Emili, J., Turner, J. M.: Factors limiting depth of a maximal inspiration in human subjects. J. appl. Physiol.18, 295 (1963).
Merill, J. P.: The treatment of renal failure, ed. 2. New York-London: Grune 1965.
Miller, J. H., Gipstein, R., Margules, R., Schwartz, F. D., Rubini, M. E.: Automated peritoneal dialysis: Analysis of several methods of peritoneal dialysis. Trans. Amer. Soc. artif. intern. Org.12, 98 (1966).
Morrow, C. S., Kantor, M., Armen, R. N.: Hepatic hydrothorax. Ann. intern. Med.49, 193 (1958).
Pacifico, A. D.: Cardiovascular function in peritoneal dialysis. Trans. Amer. Soc. artif. intern. Org.11, 86 (1965).
Perret, Cl., Baudraz, E.: Insuffisance cardio-respiratoire associé à l'obesité (syndrome pickwickien). Schweiz. med. Wschr.49, 1284 (1959).
Poinso, R., Chanas, P.: Les manifestations pleurales des cirrhotiques. Press méd.66, 1106 (1958).
Rubin, A., Russo, N., Coucher, D.: The effect of pregnancy upon pulmonary function in normal women. Amer. J. Obstet. Gynec.72, 963 (1956).
Rubin, E. H., Rubin, M.: Thoracic diseases, p. 839. Philadelphia: W. Saunders 1962.
Sanen, F. J.: Das Pickwicksche Syndrom. Med. Klin.32, 1360 (1958).
Tenckhoff, H., Ward, G., Boen, S. T.: The influence of dialysate volume and flow rate on peritoneal clearance. Proc. Europ. Dial. Transpl. Ass.2, 11 (1965).
Ulmer, W. T., Reichel, G.: Untersuchungen über die Altersabhängigkeit der alveolären und arteriellen Sauerstoff- und Kohlensäuredrucke. Klin. Wschr.41, 1 (1963).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Odriozola, J., Bahlmann, J. & Fabel, H. Einfluß der Peritonealdialyse auf die Lungenfunktion. Klin Wochenschr 49, 484–488 (1971). https://doi.org/10.1007/BF01485300
Issue Date:
DOI: https://doi.org/10.1007/BF01485300