Skip to main content
Log in

Paper plant effluent revisited-southern Lake Champlain, Vermont and New York

  • Published:
Environmental Geology

Abstract

We used geologic and geochemical techniques to document the change with time of the distribution and concentration of contaminated bottom sediments in southern Lake Champlain near an International Paper Company plant. Our work, initiated in 1972, was expanded on behalf of Vermont citizens in a class-action suit against the International Paper Company. To update our 1972–1973 results, we collected nine cores in 1988 upstream and downstream from the paper plant effluent diffuser. Water content, volatile solids, organic carbon, and three ratios, Al/Si, Cl/Si, and S/Si, in addition to megascopic and microscopic observations, were evaluated to identify and trace the distribution of effluent and to measure the thickness of sediment affected by or containing components of effluent. Analyses were carried out on samples from the cores as well as from effluent collected directly from the plant's waste treatment facility. In 1973, two years after the plant opened, we cored near the diffuser; sediment contaminated with effluent was 4.5 cm thick. In 1988, in the same area, sediment contaminated with effluent was 17 cm thick. In 15 years, water content increased from 72 to 85 percent, volatile solids from 7 to 20 percent, and organic carbon from 2 to 12 percent. Cl/Si and S/Si were high only near the diffuser and were zero elsewhere. In the area of the diffuser, contaminated sediment appears to be accumulating at a rate of about 1 cm/yr. At a control location 22 km upstream (south) from the plant, the top, poorly consoli-dated layer was only 1 cm or less thick both in 1973 and in 1988. The class-action suit was settled in favor of the plaintiffs for $5 million.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • APHA (American Public Health Association) (1971) Dissolved matter method for solid and semisolid samples. In: Standard methods for the examination of water and wastewater, 13th ed. APHA, pp 539, 541

  • Casey JP (1960) Pulp and paper: Chemistry and chemical technology, 2nd ed. New York: Interscience Publishers, 4 vol

    Google Scholar 

  • Gaudette HS, Flight WR, Toner L and Folger DW (1974) An inexpensive titration method for the determination of organic carbon in recent sediments. J. Sediment Petrol. 44:249–253

    Google Scholar 

  • LCO (Laboratory Equipment Corporation) (1959) Instruction manual for operation of LECO carbon analyzer. St. Joseph, Michigan: Laboratory Equipment Corporation, 20 pp

    Google Scholar 

  • Mason DL, Folger DW, Haupt RS, McGirr RR, and Hoyt WH (1977) Distribution of pollutants from a new paper plant in southern Lake Champlain, Vermont and New York. Environ. Geol. 1:341–347

    Google Scholar 

  • Zanetti R (1989) No paper tiger. Chem. Eng. 96(3)5

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Haupt, R.S., Folger, D.W. Paper plant effluent revisited-southern Lake Champlain, Vermont and New York. Geo 21, 77–83 (1993). https://doi.org/10.1007/BF00775054

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00775054

Key words

Navigation