Skip to main content
Log in

A stop-flow microperfusion technique for rapid determination of HCO3 absorption/H+ secretion by isolated renal tubules

  • Instruments and techniques
  • Published:
Pflügers Archiv Aims and scope Submit manuscript

Abstract.

In the present experiments on microdissected tubules of rabbit kidney we present a refined stop-flow method for determining the rate of HCO3 absorption (J HCO3) or H+ secretion (J H) that can be applied to isolated microperfused tubules. Using the pH-sensitive indicator dye BCECF (2',7'-bis [2-carboxyethyl]-5[6]-carboxyfluorescein) the luminal perfusate pH is continuously measured with a microspectrofluorometric set-up, and the pH change following a sudden stop of perfusion is analysed. Because the tubules partially collapse after stop-flow the calculation of fluxes requires a correction for volume loss. This is achieved by referring all fluxes to the remaining luminal volume, which can be estimated from the decay of the 440 nm reference fluorescence. During perfusion of the lumen with pure HCO3 Ringer solution, and of the bath with the same solution but containing 5.5 mmol/l d-glucose as metabolic substrate, J HCO3 averaged 4.4±0.2 pmol cm–1·s–1 (n=40) and 13.4±0.8 pmol·cm–1·s–1 (n=5) in proximal straight tubules (PST) and in proximal convoluted tubules respectively. These values agree very well with data obtained in other laboratories with the picapnotherm technique. The present method has the advantage of requiring fewer micromanipulations and a shorter measuring time, thus allowing regulatory changes in J HCO3 to be analysed. Moreover it does not involve measurements of radioactivity, and it also allows J H to be measured in HCO3 -free solutions which in PST averaged 0.9 pmol·cm–1·s–1 (n=8) in the present experiments.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received after revision: 20 September 1999

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Müller-Berger, S., Samarzija, I., Kunimi, M. et al. A stop-flow microperfusion technique for rapid determination of HCO3 absorption/H+ secretion by isolated renal tubules. Pflügers Arch – Eur J Physiol 439, 208–215 (1999). https://doi.org/10.1007/s004249900171

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s004249900171

Navigation