Design and operating criteria for hollow fiber bioreactors

  • Originals
  • Published:
Bioprocess Engineering Aims and scope Submit manuscript

Abstract

We have analyzed the design and operation of hollow fiber bioreactors for cell culture on the basis of cell growth efficiency and non-uniform fiber spacing. Operating diagrams are presented that describe reactor performance as a function of important operating variables like oxygen concentration and the fiber packing density. The diagrams allow one to find the best set of operating conditions for a fixed reactor design, or to rationally adjust the design parameters for fixed operating conditions.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Abbreviations

C in :

feed oxygen concentration (mass/volume)

D 2 :

diffusivity of oxygen in continuous cell mass (length/time)

R 2 :

outer radius of hollow fiber (length)

ζ :

packing efficiency (dimensionless)

φ:

Thiele modulus (dimensionless)

Φ:

cellular oxygen consumption rate (mass/volume-time)

References

  1. Chresand, R.T.;Dale, B.E.;Gillies, R.J.: Optimum fiber spacing in a hollow fiber bioreactor. Biotechnol. Bioeng.32 (8) (1988) 983–992

    Article  Google Scholar 

  2. Kelsey, L.J.;Pillarella, M.R.;Zydney, A.L.: Theoretical analysis of convective flow profiles in a hollow-fiber membrane bioreactor. Chem. Eng. Sci.45 (11) (1990) 3211–3220

    Article  CAS  Google Scholar 

  3. Sardonini, C.A.;DiBiasio, D.: An investigation of the diffusion-limited growth of animal cells around single hollow fibers. Biotechnol. Bioeng.40 (1992) 1233–1242

    Article  CAS  Google Scholar 

  4. Sardonini, C.A.;DiBiasio, D.: Growth of animal cells around hollow fibers: multifiber studies. AIChE Journal39 (8) (1993) 1415–1419

    Article  CAS  Google Scholar 

  5. Webster, I.A.;Shuler, M.L.: Mathematical models for hollow fiber enzyme reactors. Biotechnol. Bioeng.,20 (1978) 1541–1566

    Article  CAS  Google Scholar 

  6. Webster, I.A.;Shuler, M.L.;Rony, P.R.: Whole-cell hollow fiber reactor: effectiveness factors. Biotechnol. Bioeng.21 (1979) 1725–1748

    Article  CAS  Google Scholar 

  7. Ford, J.R.;Lanbert, A.;Cohen, W.;Chambers, R.: Biotechnol. Bioeng. Symposium3 (1972) 267

    Google Scholar 

  8. Cima, L.G.;Blanch, H.W.;Wilke, C.R.: A theoretical and experimental evaluation of a novel radial-flow hollow fiber reactor for mammalian cell culture. Bioproc. Engr.5 (1990) 19–30

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sardonini, C., DiBiasio, D. Design and operating criteria for hollow fiber bioreactors. Bioprocess Engineering 15, 327–330 (1996). https://doi.org/10.1007/BF02426443

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02426443

Keywords

Navigation