Computer-assisted surgery in posterior instrumentation of the cervical spine: an in-vitro feasibility study

  • Original article
  • Published:
European Spine Journal Aims and scope Submit manuscript

Abstract

Transarticular C1/2 screws are widely used in posterior cervical spine instrumentation. The use of pedicle screws in the cervical spine remains uncommon. Due to superior biomechanical stability compared to lateral mass screws, pedicle screws can be used, especially for patients with poor bone quality or defects in the anterior column. Nevertheless there are potential risks of iatrogenic damage to the spinal cord, nerve roots or the vertebral artery associated with both posterior cervical spine instrumentation techniques. Therefore, the aim of this study was to evaluate whether C1/2 transarticular screws as well as transpedicular screws in C3 and C4 can be applied safely and with high accuracy using a computer-assisted surgery (CAS) system. We used 13 human cadaver C0-C5 spine segments. We installed 1.4-mm Kirschner wires transarticular in C1/2, using a specially designed guide, and drilled 2.5-mm pedicle holes in C3 and C4 with the assistance of the CAS system. Hole positions were evaluated by palpation, CT and dissection. Forty-eight (92%) of the 52 drilled pedicles were correctly positioned after palpation, imaging and dissection. The vertebral artery was not injured in any specimen. All of the 26 C1/2 Kirschner wires were placed properly after imaging and dissection evaluations. No injury to vascular or bony structures was observed. C1/2 transarticular screws as well as transpedicular screws in the cervical spine can be applied safely and with high accuracy using a CAS system in vitro. Therefore, this technique may be used in a clinical setting, as it offers improved accuracy and reduced radiation dose for the patient and the medical staff. Nevertheless, users should take note of known sources of possible faults causing inaccuracies in order to prevent iatrogenic damage. Small pedicles, with a diameter of less than 4.0 mm, may not be suitable for pedicle screws.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 12 November 1999/Accepted: 16 November 1999

Rights and permissions

Reprints and permissions

About this article

Cite this article

Richter, M., Amiot, LP., Neller, S. et al. Computer-assisted surgery in posterior instrumentation of the cervical spine: an in-vitro feasibility study. E Spine J 9 (Suppl 1), S065–S070 (2000). https://doi.org/10.1007/PL00010024

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/PL00010024

Navigation