Quantitative scintigraphic display of myocardial blood flow

Technique and clinical evaluation

  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

Immediately after coronarography 10 mCi 133Xenon were injected into the left or right coronary artery. A scintillation camera was placed above the thorax of the patient. A computer unit (KRUPP EPR 2500) with magnetic tapes and discs is available for data processing and data storage. Sequential images of the heart are taken over a period of 2 min in a two-second-frame mode and stored on magnetic tape. The total image was divided into 5·5 mm areas. From each area a functional curve was registered and the Myocardial Blood Flow (ml/min/100 g myocard) could be calculated from that. For a precise evaluation of the image of the Myocardial Blood Flow, any influences originating from other regions of the body had to be excluded. Therefore all curves are rejected which did not (a) reach their maximum value within 15s after injection, or (b) where the maximum was less than 10% of the highest maximum value of the reference curve. The values of the Myocardial Blood Flow calculated in this manner are displayed on a TV-screen. These values can be transformed into 10 colors or grey levels.

This method has been proven to be useful in clinical practice for functional studies, especially for the judgement of the effectivity of pharmaceuticals. The quantitative display technique of the ‘Myocardial Blood Flow” improves the clinical statement in comparison to a scintigraphic picture.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Bonte, F. J., Parkey, R. W., Stokely, E. M., Lewis, S. E., Horwitz, L. D., Curry, G. C.: Radionuclide determination of myocardial blood flow. Seminars in Nuclear Med. 3, No. 2, 153–163 (1973)

    Google Scholar 

  2. Conn, H. L., Jr.: Equilibrium distributation of radioxenon in tissue: xenon-hemoglobin association curve. J. appl. Physiol. 16, 1065 (1961)

    Google Scholar 

  3. Engel, H.-J., Heim, R., Liese, W., Hundeshagen, H., Lichtlen, P.: Regional myocardial perfusion at rest in coronary disease assessed by microsphere scintigraphy and inert gas clearance. 25th session American College of Cardiology, New Orleans, Februar 1976

  4. Hundeshagen, H.: Die digitale Radionuklid-Angiokardiographie. 12. Jahrestagung d. Ges. f. Nuklearmedizin München, September 1974

  5. Hundeshagen, H., Jordan, K., Sippel, R., Nentwig, C., Gettner, U., Geisler, S.: Der Einsatz einer Prozeßrechner-gesteuerten Szintillationskamera zur phasengerechten Funktionsszintigraphie des Herzens im Vergleich zu Radiokardiographie. Tagung der Ges. f. Nuklearmedizin, Freiburg 1972

  6. Hundeshagen, H., Lichtlen, P., Liese, W., Sippel, R.: Überprüfung eines Beurteilungsschemas der Myokard-Perfusions-Szintigraphie durch die vergleichende Koronarographie. 12. Jahrestagung d. Ges. f. Nuklearmedizin München, September 1974

  7. Kety, S. S., Schmidt, C. F.: the determination of cerebral blood flow in man by use of nitrous oxide in low concentrations. Amer. J. Physiol. 144, 53 (1945)

    Google Scholar 

  8. Lichtlen, P., Engel, H.-J., Hundeshagen, H.: Regional myocardial blood flow in patients without coronary artery disease, yet proven myocardial infarctions. 25th session of the American College of Cardiology, New Orleans, Februar 1976

  9. Lichtlen, P., Gattiker, K., Scholer, Y., Schibli, R.: Koronarfluß unter Arbeit bei Koronarsklerose, gemessen anhand der präkordialen Xenon-Clearance-Technik. Verh. dtsch. Ges. Kreisl.-Forsch. 39, 301–304 (1973)

    Google Scholar 

  10. Lichtlen, P., Halter, J., Gattiker, K.: The effect of isosorbiddinitrate on coronary blood flow, coronary resistance and left ventricular dynamics under exercise in patients with coronary artery disease. Basis Res. in Cardiol. 69, No. 4, 402–421 (1974)

    Google Scholar 

  11. Lichtlen, P., Moccetti, T., Halter, J.: The importance of perfusion pressure, left ventricular work and oxygen consumption in determining myocardial blood flow in man, especially in coronary patients. Cardiology 56, 347–353 (1971/72)

    Google Scholar 

  12. Lichtlen, P., Moccetti, T., Halter, J., Schönbeck, M., Senning, A.: Postoperative evaluation of myocardial blood flow in aorta-tocoronary artery vein bypass grafts using the xenon-residue detection technic. Circulation 46, 445–455 (1972)

    Google Scholar 

  13. Liese, W., Engel, H.-J., Heim, R., Hundeshagen, H., Lichtlen, P., Rafflenbeul, W.: Diagnostische Wertigkeit der Perfusionsszintigraphie des Myokards bei Koronarsklerose. Schweiz med. Wschr. 105, 1474–1476 (1975)

    Google Scholar 

  14. Nentwig, C., Jordan, K.: Verbesserung des zeitlichen Auflösungsvermögens einer Gammakamera. In: H. W. Pabst, Nuklearmedizin. S. 309. Stuttgart: Schattauer 1973

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hundeshagen, H., Geisler, S., Dittmann, P. et al. Quantitative scintigraphic display of myocardial blood flow. Eur J Nucl Med 1, 107–115 (1976). https://doi.org/10.1007/BF00263052

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00263052

Keywords

Navigation