World health organisation inter-laboratory comparison study in 12 countries on quality performance of nuclear medicine imaging devices

  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

Twelve countries participated in the WHO inter-comparison for which transmission CAP (College of American Pathologists) brain and CAP liver phantoms and emission London liver phantoms were used. A total of 157 imaging devices were tested. Overall results from the phantoms revealed a wide range of targets detected. For the CAP-phantoms target detectability dropped below 50% for target sizes less than 9 mm and below 60% for target contrast less than 0.84:1. On average one false positive and six false negative results were reported using CAP-brain phantoms and one false positive and one false negative result using CAP-liver phantoms. For the London liver phantoms containing the tissue equivalent rubber abdominal simulation the target of 1 cm was never visualised. Two targets in this phantom (2 cm and 2.5 cm) were correctly identified in 34% of studied and one of these targets in 52% of studies. Equivocal and false positive results were reported in 42%. The WHO inter-comparison demonstrated the need to establish new, or to improve the existing, quality control programmes.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Bergmann H, Busemann-Sokole E, Baert RJM, Herrera NE (1983) Results of a quality control survey in Austria and in Netherlands using CAP-trasmission phantoms. Eur J Nucl Med 8:A6

    Google Scholar 

  • Herrera NE, Herman GA, Hauser W, Paras P (1980) College of American Pathologists Series X Survey Program. In: Medical radionuclide imaging. Proceedings of a symposium organized by IAEA in co-operation with WHO, 1–5 September 1980, Heidelberg. p 177–187

  • Mould RF (1983a) The London liver phantom, J Nucl Med 24:974–975

    Google Scholar 

  • Mould RF (1983b) Review of the recent contributions of the IAEA and WHO to quality control procedures. In: Quality control of nuclear medicine instrumentation, CRS-38. Hospital Physicists' Association, London, pp 21–30

    Google Scholar 

  • World Health Organization (1982) Quality Assurance in Nuclear Medicine. Guide prepared following a Workshop, 17–21 November 1980, held in Heidelberg. WHO, Geneva

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Volodin, V., Souchkevitch, G., Racoveanu, N. et al. World health organisation inter-laboratory comparison study in 12 countries on quality performance of nuclear medicine imaging devices. Eur J Nucl Med 10, 193–197 (1985). https://doi.org/10.1007/BF00254460

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00254460

Keywords

Navigation