Treatment of the femoral shaft fracture with a curved heat-treated COP clover-leaf nail

  • Published:
International Orthopaedics Aims and scope Submit manuscript

Summary

The commonly used straight intramedullary nail has certain limitations and disadvantages. Following radiographic and metallurgical studies we have developed a curved heat-treated clover-leaf nail using a newly developed precipitation hardening stainless steel (COP). The nail is bent with a slot on the convex side and the radius of curvature is 115 cm which corresponds to the anatomical antero-lateral convexity of the human femur. The nail has been satisfactory in clinical use since 1971 and has provided not only more stable internal fixation but also allowed fixation of fractures beyond the middle third of the shaft.

Résumé

Le clou droit intra-médullaire, d'usage courant, comporte un certain nombre de limitations et d'inconvénients. A la suite d'études radiographiques et métallurgiques, nous avons mis au point un nouveau clou courbe, en feuille de trèfle à la coupe, fabriqué avec un nouvel alliage nickel-chrome-cobalt (COP). Le clou est incurvé, avec un sillon sur sa face convexe et un rayon de courbure de 115 cm, correspondant à la convexité anatomique du fémur humain. Ce clou a été utilisé de façon satisfaisante depuis 1971, car il procure non seulement une fixation interne plus stable, mais permet également la synthèse des fractures situées au-dessous du tiers moyen de la diaphyse.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Fujimaki, A.: A biomechanical study of the fracture treatment — On the intramedullary nail of the femur. J. Orthop. Ass. 47, 321–331 (1973)

    Google Scholar 

  2. Fukushima, M.: Biomechanical study on the dynamic effect of intramedullary nailing upon the human femur. J. Orthop. Ass. 47, 215–231 (1973)

    Google Scholar 

  3. Hey-Groves, E. W.: Method and result of transplantation of bone in the repair of defects caused by injury or disease. Br. J. Surg. 5, 185–242 (1917–1918)

    Google Scholar 

  4. Küntscher, G.: Die Marknagelung von Knochenbrüchen. Arch. Klin. Chir. 200, 443–455 (1940)

    Google Scholar 

  5. Müller, M. E., Allgöwer, M., Schneider, R., Willenegger, H.: Manual der Osteosynthese-AO Technik. Berlin, Heidelberg, New York: Springer-Verlag 1979

    Google Scholar 

  6. Reynold, F. C., Key, J. A.: Fracture healing after fixation with standard plates contact splints and medullary nails. J. Bone Joint Surg. [Am.] 36, 577–587 (1954)

    Google Scholar 

  7. Stuck, W. G., Thompson, M. S.: Complication of intramedullary fixation of fractures of the femur. Arch. Surg. 63, 675–687 (1951)

    Google Scholar 

  8. Sunami, Y., Ishikawa, E.: COP, a new alloy for surgical implants. Acta Med. Okayama 31, 71–80 (1977)

    Google Scholar 

  9. Watson-Jones, R., Adams, J. C., Bonnin, J. G., Burrows, H. J., King, T., Nicoll, E. A., Palmer, L., Saal, F. V., Smith, H., Trevor, D., Vaughan-Jackson, O. G., Le Vay, A. D.: Medullary nailing of fracture after fifty years. J. Bone Joint Surg. [Br.] 32, 694–729 (1950)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Onoue, Y., Sunami, Y., Fujiwara, H. et al. Treatment of the femoral shaft fracture with a curved heat-treated COP clover-leaf nail. International Orthopaedics 3, 203–210 (1979). https://doi.org/10.1007/BF00265713

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00265713

Key words

Navigation