Skip to main content
Log in

First results of computerised tomographic angiography using electron beam tomography

  • Cardiovascular Radiology
  • Published:
European Radiology Aims and scope Submit manuscript

Abstract.

The aim of this study was to evaluate the suitability of electron beam tomography (EBT) with fast continuous volume scanning for CT angiography (CTA) in chest and abdomen. An Evolution XP EBT scanner with a new software version (12.34) was used. One hundred forty images per study can be acquired in 17 s using 3-mm collimation and overlapping image reconstruction. Study protocols for five different clinical applications of EBT CTA were established and evaluated. The EBT CTA technique was performed in 155 patients. High- and homogeneous density values were achieved along the whole course of the vessels; the mean density in the aorta was > 240 HU. Coeliac axis, superior and inferior mesenteric artery, renal and lumbar arteries were visualised in all cases. Maximum intensity projection and shaded surface display reconstruction demonstrated the relation between aneurysm and aortic branches very well due to an excellent resolution along the z-axis. In large scan volumes overlapping image reconstruction demonstrated better resolution along the z-axis than is available with helical CT. The EBT CTA technique proved to be very well suited excellent suitability for evaluation of pulmonary vessels. Compared with helical CT, EBT CTA offers a shorter scan time, which allows higher contrast enhancement in pulmonary vessels. The identification of intraluminal emboli and mural thrombi has improved. The EBT CTA technique is a very reliable tool for evaluation of aortic disease and pulmonary vessels.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 17 June 1998; Revision received: 9 September 1998; Accepted: 29 September 1998

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lehmann, K., Weisser, G., Neff, K. et al. First results of computerised tomographic angiography using electron beam tomography. Eur Radiol 9, 625–629 (1999). https://doi.org/10.1007/s003300050721

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s003300050721