Skip to main content
Log in

Zur Informationserfassung aus Ultraschall-Echogrammen in Zeit-Amplitudendarstellung

Regarding information acquisition from ultrasonic echograms in time-amplitude-presentation

  • Published:
Albrecht von Graefes Archiv für klinische und experimentelle Ophthalmologie Aims and scope Submit manuscript

Summary

Factors of the technical equipment influencing essentially the information, the redundance and the ballast in echograms are described, especially considering possibilities for tissue differentiation from time-amplitude-presentation (TAU, A-mode). The conventional evaluation of amplitude-modulation contents by visual means and the additional evaluation of frequency modulation and phase positions by instrumental processing are distinguished. For the latter approach an experimental method for the enhancement of information from small tissue structures is described which may provide improved echogram specifity. Examples are given for an extended in vitro signal acquisition and for signal processing by computer.

Zusammenfassung

Die wesentlichen apparativen Einflußgrößen auf die Information, die Redundanz und den Ballast im Ultraschall-Echogramm werden besprochen, unter besonderer Berücksichtigung von Möglichkeiten zur Gewebsdifferenzierung aus der Zeit-Amplitudendarstellung (TAU, A-Bild). Dabei wird zwischen der konventionellen, visuellen Auswertung der Amplitudenmodulations-Anteile und der zusätzlichen Auswertung von Frequenzmodulation und Phasenlagen mittels maschineller Auswertetechniken unterschieden. Auf letztere bezogen wird ein experimentelles Verfahren zur Informationsanreicherung feinstrukturbedingter und z.T. vermutlich gewebsspezifischer Signalanteile dargestellt. Es werden Beispiele für eine erweiterte Signalerfassung in vitro und rechnerische Weiterbearbeitung der Echogramme gebracht.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  • Decker, D., Epple, E., Leiss, W., Nagel, M.: Digital computer analysis of time-amplitude ultrasonograms from the human eye. II. Data processing. J. clin. Ultrasound 1, 156–159 (1973)

    Google Scholar 

  • Gassner, D., Krause, W., Soldner, R.: Der Einsatz von synthetischen Antennen und des Impulskompressionsverfahrens in der medizinischen Ultraschalldiagnostik. In: Tagungsband Signalverarbeitung, NTG im VDE, Hrsg., S. 152–159, Erlangen: Hogl 1973

    Google Scholar 

  • Giglio, E. J., Ludlam, W. M.: High resolution ultrasonic equipment to measure intra-ocular distances. J. Amer. Optom. Ass. 38, 367–371 (1967)

    Google Scholar 

  • Gordon, D.: Transducers. In: Ultrasound as a diagnostic and surgical tool, D. Gordon, ed. p. 48–56. Edinburgh-London: Livingstone 1964

    Google Scholar 

  • Grossmann, H., Millner, R.: Direktschreibende Echogrammregistrierung für die ophthalmologische Ultraschalldiagnostik. Proc. SIDUO IV,Paris 1971, M. Massin., J. Poujol., Hrsg., S. 67–69. Paris 1973

  • Ossoinig, K., Ressmann, P., Till, P.: Ein digitaler Speicher zur Computer-Analyse von Gewebsechogrammen. Proc. SIDUO IV, Paris 1971, M. Massin., J. Poujol, Hrsg. S. 93–97. Paris 1973

  • Ossoinig, K.: Ein neues Gerät für die klinische Echo-hthalmographie. Vorschläge zur Standardisation wichtiger Geräte-Parameter. Proc. SIDUO IV, Paris 1971, M. Massin., J. Poujol, Hrsg., S. 131–137. Paris 1973

  • Reuter, R., Trier, H. G.: Beitrag zur Informationserfassung aus Echogrammen in der Ophthalmologie. Vortrag Medizin-Technik, Stuttgart 1972

    Google Scholar 

  • Trier, H. G., Reuter, R.: Eine Anlage zur halbautomatischen Klassierung verschiedener Formen von Gewebsechogrammen in Zeit-Amplituden-Darstellung. Proc. SIDUO IV, Paris 1971, M. Massin., J. Poujol, Hrsg., S. 87–91. Paris 1973

  • Trier, H. G., Reuter, R.: Digital computer analysis of time-amplitude ultrasonograms from the human eye. I. Signal acquisition. J. clin. Ultrasound 1, 150–154 (1973)

    Google Scholar 

  • Trier, H. G., Reuter, R.: The influence of pulse qualities on the echo envelop. Vortrag SIDUO V, Gent 1973, im Druck

  • Trier, H. G., Reuter, R., Decker, D., Epple, E: Neuere Ansätze zur Informationserfassung aus Echogrammen in der Ophthalmologie. Vortrag Deutsche Ophthalmologische Gesellschaft Heidelberg 1973, im Druck

Download references

Author information

Authors and Affiliations

Authors

Additional information

Herrn Prof. Dr. H. K. Müller zum 75. Geburtstag gewidmet.

Wesentliche Teile wurden beim Kongreß „Medizin-Technik 1972“, Stuttgart, am 15. 5. 1972 vorgetragen.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Reuter, R., Trier, H.G. Zur Informationserfassung aus Ultraschall-Echogrammen in Zeit-Amplitudendarstellung. Albrecht von Graefes Arch. Klin. Ophthalmol. 189, 219–230 (1974). https://doi.org/10.1007/BF00414783

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00414783