Summary

The paper reports on haemodynamic observations in 20 calves surviving total heart replacement by an incorporated double chamber blood pump for more than 10 h.

The following parameters are registered:

  • - pressures in both atria and vena cava inferior,

  • - pressures in aorta and pulmonary artery,

  • - pressures in both artificial ventricles,

  • - pressures in the pneumatic driving system,

  • - perfusion volumes and AVDO2.

It is demonstrated that the artificial blood pumps are able to obtain a perfusion volume sufficient for the animal's vitality.

A sufficient regulation can be achieved by varying the driving system and by the so called Starling-mechanism of the artificial heart.

In the long time surviving animals an increase of the right atrium pressure, and of the perfusion volumes is found while total peripheral resistance decreases.

To explain these observations, disturbances of the neurohumoral circulatory control by the action of the artificial pumps or the development of sepsis are discussed.

Zusammenfassung

Über hämodynamische Beobachtungen bei 20 Kälbern, die den Totalersatz des Herzens mit einer inkorporierten zweikammerigen Blutpumpe länger als 10 Std überlebten, wird an Hand folgender Parameter berichtet:

  • - Drucke in beiden Vorhöfen und in der unteren Hohlvene,

  • - Drucke in Aorta und Pulmonalis,

  • - Drucke in beiden künstlichen Ventrikeln,

  • - Drucke in dem pneumatischen Antriebssystem,

  • - Perfusionsvolumina und AVDO2.

Es wird gezeigt, daß die künstlichen Blutpumpen in der Lage sind, ein der Vitalität der Tiere genügendes Perfusionsvolumen zu fördern. Die Steuerungsmöglichkeiten einmal über Änderungen der Antriebsgrößen, zum anderen über den sog. Starling-Mechanismus des künstlichen Herzens, erweisen sich als den Anforderungen genügend.

Nach längeren Überlebenszeiten findet sich ein Anstieg des rechten Vorhofdruckes, eine Zunahme der Perfusionsvolumina und somit bei annähernd konstanten arteriellen Drucken ein Absinken des peripheren Gesamtwiderstandes.

Zur Deutung dieser Beobachtungen werden u. a. diskutiert Störungen der neurohumoralen Kreislaufregulation durch die Aktion der künstlichen Blutpumpen oder etwa der mögliche Einfluß eines septischen Krankheitsbildes. Prof. Dr. E. S. Bücherl

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Krautzberger, W., Clevert, D., Kleine, H., Lüdke-Handjery, A., Affeld, K., Wallner, F., Mohnhaupt, R., Bücherl, E. S.: Anatomische und operationstechnische Gesichtspunkte bei der Implantation eines künstlichen Herzens, Langenbecks Arch. Chir.329, 384 (1971)

    Google Scholar 

  2. Moulopoulos, S. D., Jarvick, R., Kolff, W.J.: Stage II problems in the project of the artificial heart. J. thorac. cardiovasc. Surg.66, 662 (1973)

    PubMed  Google Scholar 

  3. Kennedy, J. H., De Bakey, M. E., Akers, W. W., Ross, J. W., O'Bannon, W., Baker, L. E., Greenberg, S. D., Wieting, D. W., Lewis, C. W., Adachi, M., Alfrey, C. P., Spargo, W. J., Gugua, J. M.: Progress towards an orthotopic cardiac prothesis. Biomat., Med. Dev., Art. Org.1, 3 (1973)

    Google Scholar 

  4. Mohnhaupt, R., Affeld, K., Mohnhaupt, A., Bücherl, E. S.: Über antriebsseitige Messungen von Kreislauf- und Antriebsgrößen an künstlichen Herzen. Fachbericht Jahrestagung Deutsche Gesellschaft für Biomedizinische Technik1973,125

  5. Gauer, 0. H., Kramer, K., Jung, R.: Physiologie des Menschen, Bd. 3. München-Berlin-Wien: Urban und Schwarzenberg 1972

    Google Scholar 

  6. Burton, A. C.: Physiologie und Biophysik des Kreislaufs. Stuttgart-New York: Schattauer 1969

    Google Scholar 

  7. Wildevuur, C. R. H., Mrava, G. L., Crosby, M. J., Wright, J., Hladky, H. L., Anderson, G. J., Pierson, R. M., Kon, T., Nosé, Y.: An artificial heart sensitive to atrial volume. Trans. Amer. Soc. artif. intern. Org.14, 276 (1968)

    Google Scholar 

  8. Brighton, J. A., Wade, Z. A., Pierce, W. S., Phillips, W. M., O'Bannon, W.: Effect of atrial volume on the performance of a sac-type artificial heart. Trans. Amer. Soc. artif. intern. Org.19, 567 (1973)

    Google Scholar 

  9. Kito, Y., Takagi, H., Honda, T., Gibson, W. H., Akutsu, T.: Recent results in total artificial heart. Trans. Amer. Soc. artif. intern. Org.19, 573 (1973)

    Google Scholar 

  10. Olsen, D., van Kampen, K., Volder, J., Kolff, W. J.: Pulmonary hepatic and renal pathology associated with an artificial heart. Trans. Amer. Soc. artif. intern. Org.19, 578 (1973)

    Google Scholar 

  11. Klain, M., Mrava, G. L., Tajima, K., Schriber, K., Webb, J., Ogawa, H., Opplt, J., Nosé, Y.: Can we achieve over -100 hours survival with a total mechanical heart ? Trans. Amer. Soc. artif. intern. Org.17, 437 (1971)

    Google Scholar 

  12. Takano, H., Takagi, H., Turner, M. D., Menson, E. C., Crowell, J. W., Akutsu, T.: Problems in total artificial heart. Trans. Amer. Soc. artif. intern. Org.17, 449 (1971)

    Google Scholar 

  13. Kawai, J., Peters, J., Donovan, F., Hershgold, E. J., Rowley, K., Kolff, W. J.: Implantation of a total artificial heart in calves under hypothermia with 10 day survival. J. thorac. cardiovasc. Surg.64, 45 (1972)

    Google Scholar 

  14. Akutsu, T., Takano, H., Takagi, H., Turner, M. D., Henson, E. C., Crowell, J. W.: Pathophysiology and new problems in total artificial heart. J. thorac. cardiovasc. Surg.64, 762 (1972)

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Krautzberger, W., Clevert, H.D., Keilbach, H. et al. Hämodynamik nach Ersatz des Herzens durch eine inkorporierte doppelkammerige Blutpumpe. Langenbecks Arch Chiv 335, 171–186 (1974). https://doi.org/10.1007/BF01251636

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01251636

Key words

Navigation