Skip to main content
Log in

Solid-phase radioimmunoassay in antibody-coated tubes for the quantitative determination of tetanus antibodies

  • Published:
Medical Microbiology and Immunology Aims and scope Submit manuscript

Abstract

A technique using antibody-coated tubes allows the radioimmunological determination of tetanus antibodies in a simple and rapid way. The procedure is based on the competition for125I-tetanus toxin between the insolubilized antibodies and the antibodies present in the unknown sample. When antibodies and125I labeled tetanus toxin are incubated in the antibody-coated polyethylene vessel the detection limit is about 0.016 IU/ml. When tetanus toxin is preincubated together with its antibody in uncoated vessels before the mixture is transferred to antibody-coated vessels, the sensitivity can be raised about tenfold.

The method is especially useful for screening multiple samples.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Catt, K., Niall, H. D., Tregear, G. W.: Solid phase radioimmunoassay. Nature (Lond.)213, 825 (1967)

    Google Scholar 

  2. Catt, K., Tregear, G. W.: Solid-phase radioimmunoassay in antibody-coated tubes. Science158, 1570 (1967)

    PubMed  Google Scholar 

  3. Habermann, E., RÄker, K. O., Zeuner, G.: Solid-phase-Radioimmunassay und Blutspiegel von Staphylokokken-α-Toxin. Naunyn-Schmiedebergs Arch. Pharmak.262, 165 (1969)

    Google Scholar 

  4. Habermann, E., Wiegand, H.: A rapid and simple radioimmunological procedure for measuring low concentrations of tetanus antibodies. Naunyn-Schmiedeberg's Arch. Pharmacol.276, 321 (1973)

    Google Scholar 

  5. Habermann, E., Dimpfel, W.: Distribution of125I-tetanus toxin and125I-toxoid in rats with generalized tetanus, as influenced by antitoxin. Naunyn-Schmiedeberg's Arch. Pharmacol.276, 327 (1973)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bernáth, S., Habermann, E. Solid-phase radioimmunoassay in antibody-coated tubes for the quantitative determination of tetanus antibodies. Med Microbiol Immunol 160, 47–51 (1974). https://doi.org/10.1007/BF02124342

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02124342

Keywords

Navigation