Abstract

To investigate the application of a mini-coil surface system for high-resolution MRI, 60 volunteers were examined in a 1.5-T whole-body scanner. Two replaceable probe heads were available: a circular 2.5-cm coil and a quadratic 5-cm coil, both of which were placed directly on the skin. The skin layers, Achilles tendon and finger joints were examined with the 2.5-cm coil and a FOV of 25 × 25 mm2. A matrix of 256 × 256 pixels resulted in a pixel size of 0.098 × 0.098 mm2. For imaging of the carpal tunnel, the 5-cm coil was used in transverse orientation. The FOV was 50 × 50 mm2 so that a matrix of 256 × 256 pixels led to a pixel size of 0.195 × 0.195 mm2. The resulting spatial resolution permitted visualization of the epidermis, dermis and subcutis, resulting in clear definition of anatomical detail of the musculoskeletal system. MRI measurement of skin-layer thickness did not correlate with histometric data (p<0.05). This discrepancy was due in part to shrinkage of the tumor specimen on histologic preparation. Other causes include the motion artifacts and the limited accuracy of determining thickness on the MRI display unit.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Aguayo JB, Blackband SJ, Schoeninger J, Mattingly MA, Hintermann M (1986) Nuclear magnetic resonance imaging of a single cell.Nature 322: 190–191.

    PubMed  Google Scholar 

  2. Fisher MR, Barker B, Amparo EG, et al. (1985) MR imaging using specialized coils.Radiology 157: 443–447.

    PubMed  Google Scholar 

  3. Froncisz W, Jesmanowicz A, Kneeland JB, Hyde JS (1986) Counter rotating current local coils for high-resolution magnetic resonance imaging.Magn Reson Med 3: 590–603.

    PubMed  Google Scholar 

  4. Hayes CE, Axel L (1985) Noise performance of surface coils for magnetic resonance imaging at 1.5 T.Med Phys 12: 604–607.

    PubMed  Google Scholar 

  5. Hyde JS, Froncisz W, Jesmanowicz A, Kneeland JB (1988) Simultaneous image acquisition from the head (or body) coil and a surface coil.Magn Reson Med 6: 235–239.

    PubMed  Google Scholar 

  6. Mäurer J, Requardt H, Müller FH, Böck JC, Felix R (1993) High-resolution magnetic resonance in clinical image system.The Lancet 342: 310.

    Google Scholar 

  7. Mäurer J, Requardt H, Müller F, Steinkamp HJ, Hosten N, Langer R, Felix R (1994) Indikationen zur Applikation einer Hochauflösungsspule in der MR-Tomographie.Fortschr Rontgenstr 160: 353–360.

    Google Scholar 

  8. Jesmanowicz A, Hyde JS, Kneeland JB (1988) Pulse sequences for small fields of view.Book of Abstracts, Society of Magnetic Resonance in Medicine, Seventh Annual Meeting, San Francisco, p. 1041.

  9. Bittoun J, Saint-Jalmes H, Querleux BG, et al. (1990) In vivo high-resolution MR imaging of the skin in a whole-body system at 1.5 T.Radiology 176: 457–460.

    PubMed  Google Scholar 

  10. Querleux B, Yassine MM, Darasse L, Saint-Jalmes H, Sauzade M, Leveque JL (1988) Magnetic resonance imaging of the skin. A comparison with the ultra-sonic technique.Bioeng Skin 4: 1–14.

    Google Scholar 

  11. Erickson SJ, Kneeland JB, Middleton WD et al. (1989) MR imaging of the finger: Correlation with normal anatomic sections.AJR 152: 1013–1019.

    PubMed  Google Scholar 

  12. Hyde JS, Jesmanowicz A, Kneeland JB (1987) Surface coil for MR imaging of the skin.Magn Reson Med 5: 456–461.

    PubMed  Google Scholar 

  13. Richard S, Querleux B, Bittoun J, Idy-Peretti I, Jolivet O, Cermakova E, Leveque J-L (1991)J Invest Dermatol 97: 120–125.

    PubMed  Google Scholar 

  14. El-Gammal S, Auer T, Hoffmann K, Matthes U, Altmeyer P (1992) Möglichkeiten und Grenzen der hochauflösenden (20 und 50 MHz) Sono-graphie in der Dermatologie.Akt Dermatol 18:197–208.

    Google Scholar 

  15. Fornage BD, McGavran MH, Duvic H, Waldtron CA (1993) Imaging of the skin with 20-MHz US.Radiology 189: 69–76.

    PubMed  Google Scholar 

  16. Zemtsov A, Lorig R, Thian C et al. (1991) Magnetic resonance imaging of cutaneous neoplasms.J Dermatol Surg Oncol 17: 16–122.

    Google Scholar 

  17. Breslow A (1970) Thickness, cross-sectional areas and depth of invasion in the prognosis of cutaneous mela-noma.Ann Surg 172: 902–908.

    PubMed  Google Scholar 

  18. Zemtsov A, Lorig R, Bergfield WF, Bailin PL, Thian C (1989) Magnetic resonance imaging of cutaneous melanocytic lesions.J Dermatol Surg Oncol 15: 854–858.

    PubMed  Google Scholar 

  19. Zemtsov A, Dixon L (1993) Magnetic resonance in dermatology.Arch Dermatol 123: 21–28.

    Google Scholar 

  20. Takahashi M, Kohda H (1992) Diagnostic utility of magnetic resonance imaging in malignant melanoma.J Am Acad Dermatol 16: 51–54.

    Google Scholar 

  21. Schwaighofer BW, Frühwald FXJ, Pohl-Markl H, et al. (1989) MRI evaluation of pigmented skin tumors.Invest Radiology 24: 289–293.

    Google Scholar 

  22. Schönbauer HR (1986) Erkrankungen der Achillessehne.Wiener klinische Wochenschrift (98)6: 3–47.

    Google Scholar 

  23. Stiskal M, Neuhold A, Weinstabl R, Kainberger FM, Gisinger B (1990) MR-tomographische Befunde bei Achillodynie.Fortschr Röntgenstr 153: 9–13.

    Google Scholar 

  24. Middleton WD, Kneeland JB, Kellman GM et al (1987) MR imaging of the carpal tunnel: Normal anatomy and preliminary findings in the carpal tunnel syndrome.AJR 148: 307–316.

    PubMed  Google Scholar 

  25. Weiss KL, Bertran J, Shaman OM, Stilla RF, Levey MB (1986) High field MR surface-coil imaging of the hand and wrist.Radiology 160: 143–146.

    PubMed  Google Scholar 

  26. Schmidt H-M, Moser T, Lucas D (1987) Klinisch-anatomische Untersuchun-gen des Karpaltunnels der menschlichen Hand.Handchir 19: 145–152.

    Google Scholar 

  27. Tanzer RC (1959) The carpal-tunnel syndrome: A clinical and anatomic study.Bone Joint Surg (Am)41: 626–634.

    Google Scholar 

  28. Foo TKF, Shellock FG, Hayes CE, Schenck JF, Slayman BE (1992) High-resolution MR imaging of the wrist and eye with short TR, short TE and partial-echo acquisition.Radiology 183: 277–281.

    PubMed  Google Scholar 

  29. Dion E, Oberlin C, Codanda et al. (1992) IRM en haute resolution du canal carpien.J Radiol 73: 293–301.

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Mäurer, J., Requardt, H., Sander, B. et al. Applications of specialized coils for high-resolution MRI on a whole-body scanner. MAGMA 4, 27–33 (1996). https://doi.org/10.1007/BF01759777

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01759777

Keywords

Navigation