Self-calibrating interference refractometer using a linear photodiode array for anaesthetic gas analysis

  • Instrumentation
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

The laboratory standard for measurement of gas concentrations in binary mixtures is the manually operated interfence refractometer. We describe an automatic interference refractometer for theatre use incorporating a linear photodiode array and using digital electronics for signal analysis. The support system performs automatic self-calibration, samples gases from an anaesthetic machine, feeds them to the refractometer and presents information on gas concentrations and possible alarm conditions to the anaesthetist. The instrument may be incorporated into a new anaesthetic machine or may be an addition to an existing one. The instrument may also be applied in other fields where concentrations of known gases need to be monitored automatically.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Cooper, J. B., Edmondson, J. H., Joseph, D. M. andNewbower, R. S. (1981) Piezoelectric sorption anaesthetic sensor.IEEE Trans.,BME-28, 459–466.

    Google Scholar 

  • Diprose, K. V. andRedman, L. R. (1978) An automatic interference refractometen.Br. J. Anaesth.,50, 1155–1157.

    Google Scholar 

  • Edmondson, W. (1957) Gas analysis by refractive index measurement.,29, 570–574.

    Google Scholar 

  • Hill, D. W. (1974) Methods for the analysis of gases and vapours. InScientific foundations of anaesthesia, 2nd edn.,Scurr, C. andFeldman, S. (Eds.), Heinemann, London, Chap. 7, 85–97.

    Google Scholar 

  • Hulands, G. H. andNunn, J. F. (1970) Portable interference refractometers in anaesthesia.Br. J. Anaesth.,42, 1051–1059.

    Google Scholar 

  • Jeavons, P. (1987) Automated interference refractometer: an algorithm for locating an irregular fringe pattern.J. Biomed. Eng.,9, 157–160.

    Google Scholar 

  • Penlon Ltd. (1985) Gas analysis apparatus and method. European Patent 85304410.5 (20-6-85).

  • E G & G Reticon. G series solid state line scanners (1–19 to 1–22). Product Literature. 345 Potrero Avenue, Sunnyvale, CA 94086, USA.

  • Tyndall, J. (1965) On radiation. The Rede lecture.Royal College of Surgeons of England Tracts,139A, 4.1.

    Google Scholar 

  • Zbinden, A. M., Westenskow, D., Thomson, D. A., Funk, B. andMaertens, J. (1986) A laboratory investigation of two new portable gas analysers.Int. J. Clin. Mon. & Comput.,2, 151–161.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations