Television measurement pulse generator-mixer

  • Published:
Medical and biological engineering Aims and scope Submit manuscript

Abstract

Measurement instrumentation is presented that has been designed for use with the Intra-oral Television Microscope and Television Micro and Macrodensity Instrumentation. It can also be applied to any television display from other input sources. The equipment, which is capable of collecting measurement data from a particular scan line and/or any point within a scan line of the television image, is discussed from the standpoint of design and operation. Identification of the area measured, along with illuminated reference marker dots within the scan line being measured, make it possible to calibrate the instrumentation, regardless of the magnification of the televised image.

Sommaire

L'article décrit un ensemble d'instrumentation mis au point pour l'exploitation d'un équipement de microscopie intra-buccale par télévision et d'un micro et macro densitomètre par télévision. Il peut également s'appliquer à tout autre équipement dont l'exploitation se fait sur écran de télévision. Cet appareil est susceptible de recueillir une information issué d'une ligne donnée et/ou d'un point donné d'une ligne d'une image télévisée. Il est décrit dans l'optique de sa réalisation et de sa mode de fonctionnement. La possibilité qu'il offre de référer des zones de mesure par marquage lumineux se superposant à l'image rend l'appareil apte à calibrer l'ensemble de la chaine de mesure indépendamment de l'aggrandissement apporté par l'image.

Zusammenfassung

Ein Meßsystem wird dargestellt, das zur Verwendung beim intraoralen Fernsehmikroskop und bei dem Fernseh- Mikro- und Makrodichteinstrument entwickelt wurde. Es kann auch zu Fernseh-abbildungen bei anderen Eingangsquellen benutzt werden. Das Gerät, das Meßdaten von einer bestimmten Scan-Linie und/oder jedem Punkt innerhalb der Scan-Linie des Fernsehbildes aufnehmen kann, wird hinsichtlich Konstruktion und Arbeitsweise diskutiert. Das Instrument kann unabhängig von der Vergrößerung des Fernsehbildes geeicht werden; das geschieht mit Hilfe der Identifizierung der Meßfläche und mit erleuchteten Markierungspunkten innerhalb der gemessenen Scan-Linie.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Horwitz, B. A. (1966) Clinical television micromeasurement of cavity margin deterioration. Thesis, Indiana University School of Dentistry.

  • Kerkhove, B. C. (1964) A clinical and television densitometric evaluation of the indirect pulp capping technique. Thesis, Indiana University School of Dentistry.

  • Klein, A. I. (1963) The television microscope in dental research.Dent. Progr. 3, 274–279.

    Google Scholar 

  • Sanders, J. J. (1965) Data extraction from a video display.I.E.E.E. Trans. Bio-Med. Engng BME-12, 147–154.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

This study was supported in part by United States Public Health Service Grant DE 01813 from the National Institute of Dental Research, National Institute of Health, Bethesda, Maryland.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Klein, A.I., Macpherson, D. Television measurement pulse generator-mixer. Med. & biol. Engng. 5, 267–270 (1967). https://doi.org/10.1007/BF02474536

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02474536

Keywords

Navigation