Summary
We report a case of pulmonary atresia in which the ductus arteriosus underwent aneurysmal dilatation after infusion of prostaglandin E1 incorporated in lipid microspheres. To our knowledge this is the first case in which this rare morphological change has been demonstrated with the noninvasive method of magnetic resonance imaging.
Similar content being viewed by others
References
Chung KJ, Simpson IA (1990) Magnetic resonance imaging of congenital heart disease: right heart lesions. In: Crupi G, Parenzan L, Anderson RH (eds)Perspectives in pediatric cardiology, vol. 2,Pediatric cardiac surgery, part 3, Futura, New York, pp 66–68
Cole RB, Abman S, Aziz KU, Bharati S, Lev M (1981) Prolonged prostaglandin E1 infusion: histological effects on the patent ductus arteriosus.Pediatricus 67:816–819
Freed MD, Heymann MA, Lewis AB, Roehl SL, Kensey RC (1981) Prostaglandin E1 in infants with ductus arteriosus-dependent congenital heart disease.Circulation 64:899–905
Lewis AB, Freed MD, Heymann MA, Roehl SL, Kensey RC (1981) Side effects of therapy with prostaglandin E1 in infants with critical congenital heart disease.Circulation 64:893–898
Momma K, Takao A (1987) Lipo prostaglandin E1 (Lipo PGE1) in the treatment of infants with ductus-arteriosus-dependent pulmonary blood flow.Circulation 76 (suppl IV): 25
Pitlick P, French JW, Maze A, Kimble KJ, Ariagno RL, Reitz BA (1980) Long-term low-dose prostaglandin E1 administration.J Pediatr 96:318–320
Silver MM, Freedom RM, Silver MD, Olley PM (1981) The morphology of the human newborn ductus arteriosus: a reappraisal of its structure and closure with special reference to prostaglandin E1 therapy.Hum Pathol 12:1123–1136
Teixeira OHP, Carpenter B, MacMurray SB, Vlad P (1984) Long-term prostaglandin E1 therapy in congenital heart defects.JACC 3:838–843
Ueda K, Saito A, Nakano H, et al. (1980) Cortical hyperostosis following long-term administration of prostaglandin E1 in infants with cyanotic congenital heart disease.J Pediatr 97:834–836
Yokota M, Muraoka R, Aoshima M, et al. (1985) Modified Blalock-Taussig shunt following long-term administration of prostaglandin E1 for ductus-dependent neonates with cyanotic congenital heart disease.J Thorac Cardiovasc Surg 90:399–403
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Tsubata, S., Hashimoto, I., Ichida, F. et al. Aneurysmal change of the ductus arteriosus after prostaglandin E1 administration for pulmonary atresia: Demonstration with magnetic resonance imaging. Pediatr Cardiol 15, 30–32 (1994). https://doi.org/10.1007/BF00797003
Issue Date:
DOI: https://doi.org/10.1007/BF00797003