MR cholangiopancreatography: comparison between half-Fourier acquisition single-shot turbo spin-echo and two-dimensional turbo spin-echo pulse sequences

  • Published:
Abdominal Imaging Aims and scope Submit manuscript

Abstract

Background: To compare half-Fourier acquisition single-shot turbo spin-echo (HASTE) magnetic resonance cholangiopancreatography (MRCP) with two-dimensional turbo spin-echo (2D TSE) MRCP for imaging pancreatobiliary diseases.

Methods: Twenty-seven patients with biliary or pancreatic disease underwent MRCP on a 1.0-T scanner with a body phased-array coil. A T2-weighted HASTE sequence (18 s) and a T2-weighted 2D TSE sequence (45 s) were used during a breath-hold by the patient. The source images and maximum intensity projection images of both sequences were reviewed independently by two radiologists.

Results: Motion artifacts were more severely pronounced with 2D TSE sequences than with HASTE sequences (p < 0.001). All obstructions and their sites were accurately identified with both sequences. Filling defects (calculi) in bile ducts were identified in all 22 segments (100%) with HASTE-MRCP, whereas calculi in 19 of 22 segments (86%) were identified with 2D TSE-MRCP (p= 0.25). Three missed sites on 2D TSE-MRCP were intrahepatic bile ducts.

Conclusions: HASTE-MRCP is superior to 2D TSE-MRCP in terms of detecting motion artifacts and visualization of the pancreatic ducts. HASTE-MRCP is comparable to 2D TSE-MRCP for visualization of the biliary ducts and their obstruction and is superior to 2D TSE-MRCP for identification of calculi in intrahepatic bile ducts.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kim, T., Han, J., Kim, S. et al. MR cholangiopancreatography: comparison between half-Fourier acquisition single-shot turbo spin-echo and two-dimensional turbo spin-echo pulse sequences. Abdom Imaging 23, 398–403 (1998). https://doi.org/10.1007/s002619900368

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002619900368

Key words

Navigation