Ein Verfahren zur\(p_{a_{CO_2 } } \)-geregelten automatischen Ventilation

A system of continuously 319-2319-2319-2-controlled ventilation

  • Published:
Pneumonologie Aims and scope Submit manuscript

Abstract

A newly developed system of\(p_{a_{CO_2 } } \)-controlled automatic ventilation is demonstrated. ApCO 2-catheter electrode is used to monitor arterialpCO 2 continuously. The output voltage of thepCO 2 amplifier is fed into a regulator amplifier that compares it with a set voltage. The output voltage of the regulator controls an automatic respirator. All details of the automatic ventilation are described.

Zusammenfassung

Ein neu entwickeltes System zur\(p_{a_{CO_2 } } \)-geregelten Ventilation wird vorgestellt. Mit Hilfe einerp CO 2-Katheterelektrode (Fa. General Electric) wird kontinuierlich der arterielle Kohlensäurepartialdruck gemessen. Die in einenp CO2-Regler einlaufenden Potentiale werden mit einem variabel einstellbaren\(p_{a_{CO_2 } } \)-Sollwert verglichen. Die Spannungs-differenz zwischen\(p_{a_{CO_2 } } \)-Soll- und Istwert modifiziert die Ventilationsvorgabe eines mit Servo-Ventilen arbeitenden Beatmungsgerätes (Servo-Ventilator 900, Fa. Dräger) so lange nach, bis sich bei minimaler Regelabweichung\(p_{a_{CO_2 } } \)-Soll- und Istwert entsprechen. Die Arbeitscharakteristika der einzelnen Glieder des Regelkreises werden besprochen.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Literatur

  1. Mitamura, Y., Mikami, T., Yamamoto, K., Kimura, M.: A dual control system of artificial respiration. 10th International Conference on Medical and Biological Engineering, Dresden, Session 10, Respiration I, p. 144 (1973)

  2. Schulz, V., Erdmann, W., Ulmer, H. V., Kunke, S., Baum, P., Frey, R.: Zur kontinuierlichen Messung des arteriellen Kohlensäuredrucks mit Katheterelektroden und Möglichkeiten ihres klinischen Einsatzes. Anaesthesist22 416 (1973)

    PubMed  Google Scholar 

  3. Weerden, G. J. van, Handels, J. J. A. M.: The value of capnography for regulation of artificial ventilation. Abstr. Symp. Anaesth. Int. Prag. 17.–20. Aug. 1965

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Schulz, V., Ulmer, H.V., Erdmann, W. et al. Ein Verfahren zur\(p_{a_{CO_2 } } \)-geregelten automatischen Ventilation. Pneumologie 150, 319–325 (1974). https://doi.org/10.1007/BF02179336

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02179336

Key words

Navigation