Skip to main content
Log in

Cerebral haemodynamic changes after endovascular treatment of arteriovenous malformations: Evaluation by single-photon emission CT

  • Clinical Articles
  • Published:
Acta Neurochirurgica Aims and scope Submit manuscript

Summary

Cerebral haemodynamic changes in 17 patients with cerebral arteriovenous malformations (AVMs), who showed hypoperfusion on single-photon emission computed tomography (SPECT) before endovascular treatment, were studied after embolization. Nine of them had non-haemorrhagic clinical manifestations and the other eight had a history of intracranial haemorrhage. Obliteration of AVMs was nearly total in six patients and partial in eleven.

New low density lesions on X-ray computed tomography (CT) developed in 3 of 6 patients after nearly total obliteration and one of 11 patients after partial obliteration.

The first SPECT after embolization showed diminished hypoperfusion in 11 of 13 patients without new low density lesions and one of 4 patients with new low density lesions. Diminution of hypoperfusion was seen even in two patients who underwent SPECT study immediately after the embolization. Cerebral circulation was improved in five of eight patients with low density lesions before embolization and in nine of eleven patients after partial obliteration. Hypoperfused state in the haemorrhagic group tended to remain unchanged compared with that in the non-haemorrhagic group. The hypoperfused area was expanded after embolization in three patients with new cerebral infarction.

It is important for improvement of cerebral circulation to reduce the shunt flow without causing new infarction due to the embolization itself. In one of two patients who had a hyperperfused area surrounding the AVM after embolization, an unexpected and abnormal degree of brain swelling and haemorrhage occurred at the end of the surgery 20 days after the embolization. In the other patient, total extirpation was successfully performed after confirming disappearance of hyperperfusion in the follow-up SPECT.

SPECT allows repeated measurement of the cerebral blood flow pattern easily and safely, and is useful for AVM management.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Barnett GH, Little JR, Ebrahim ZY, Jones SC, Friel HT (1987) Cerebral circulation during arteriovenous malformation operation. Neurosurgery 20: 836–842

    PubMed  Google Scholar 

  2. Batjer HH, Devous MD Sr, Meyer YJ, Purdy PD, Samson DS (1988) Cerebrovascular hemodynamics in arteriovenous malformation complicated by normal perfusion pressure breakthrough. Neurosurgery 22: 503–509

    PubMed  Google Scholar 

  3. Batjer HH, Devous MD Sr, Seibert GB, Purdy PD, Ajmani AK, Delarosa M, Bonte FJ (1989) Intracranial arteriovenous malformation: contralateral steal phenomena. Neurol Med Chir (Tokyo) 29: 401–406

    Google Scholar 

  4. Batjer HH, Purdy PD, Giller GA, Samson DS (1989) Evidence of redistribution of cerebral blood flow during treatment for an intracranial arteriovenous malformation. Neurosurgery 25: 599–605

    PubMed  Google Scholar 

  5. Creutzig H, Schober O, Gielow P, Friedrich R, Becker H, Dietz H, Hundeshagen H (1986) Cerebral dynamics of N-isopropyl-(123I)p-iodoamphetamine. J Nucl Med 27: 178–183

    PubMed  Google Scholar 

  6. Hassler W, Steinmetz H (1987) Cerebral hemodynamics in angioma patients: an intraoperative study. J Neurosurg 67: 822–831

    PubMed  Google Scholar 

  7. Hayashida K, Nishimura T, Imakita S, Uehara T, Nakamura M, Tsuchiya T, Hasegawa Y (1991) Change of accumulation and filling pattern in evolution of cerebral infarction with I-123 IMP brain SPECT. Neuroradiology 33: 9–14

    PubMed  Google Scholar 

  8. Homan RW, Devous MD Sr, Stokely EM, Bonte FJ (1986) Quantification of intracerebral steal in patients with arteriovenous malformation. Arch Neurol 43: 779–785

    PubMed  Google Scholar 

  9. Kusske JA, Kelly WA (1974) Embolization and reduction of the “steal” syndrome in cerebral arteriovenous malformations. J Neurosurg 40: 313–321

    PubMed  Google Scholar 

  10. Marks MP, O'Donahue J, Fabricant JI, Frankel KA, Phillips MH, DeLaPaz RL, Enzmann DR (1988) Cerebral blood flow evaluation of arteriovenous malformations with stable xenon CT. AJNR 9: 1169–1175

    PubMed  Google Scholar 

  11. Mendelow AD, Erfurth A, Grossart K, Macpherson P (1987) Do cerebral arteriovenous malformations increase in size? J Neurol Neurosurg Psychiatry 50: 980–987

    PubMed  Google Scholar 

  12. Minakawa T, Tanaka R, Koike T, Takeuchi S, Sasaki O (1989) Angiographic follow-up study of cerebral arteriovenous malformations with reference to their enlargement and regression. Neurosurgery 24: 68–74

    PubMed  Google Scholar 

  13. Okabe T, Meyer JS, Okayasu H, Harper R, Rose J, Grossman RG, Centeno R, Tachibana H, Lee YY (1983) Xenon-enhanced CT CBF measurements in cerebral AVM's before and after excision. Contribution to pathogenesis and treatment. J Neurosurg 59: 21–31

    PubMed  Google Scholar 

  14. Rosenblum BR, Bonner RF, Oldfield EH (1987) Intraoperative measurement of cortical blood flow adjacent to cerebral AVM using laser Doppler velocimetry. J Neurosurg 66: 396–399

    PubMed  Google Scholar 

  15. Spetzler RF, Martin NA, Carter LP, Flom RA, Raudzens PA, Wilkinson E (1987) Surgical management of large AVM's by staged embolization and operative excision. J Neurosurg 67: 17–28

    PubMed  Google Scholar 

  16. Spetzler RF, Wilson CB, Weinstein P, Mehdorn M, Townsend J, Telles D (1978) Normal perfusion pressure breakthrough theory. Clin Neurosurg 25: 651–672

    PubMed  Google Scholar 

  17. Takeuchi S, Kikuchi H, Karasawa J, Naruo Y, Hashimoto K, Nishimura T, Kozuka T, Hayashi M (1987) Cerebral hemodynamics in arteriovenous malformations: evaluation by single-photon emission CT. AJNR 8: 193–197

    PubMed  Google Scholar 

  18. Tarr RW, Johnson DW, Horton JA, Yonas H, Pentheny S, Durham S, Jungreis CA, Hecht ST (1991) Impaired cerebral vasoreactivity after embolization of arteriovenous malformations: assessment with serial acetazolamide challenge xenon CT. AJNR 12: 417–423

    PubMed  Google Scholar 

  19. Tsukuda M, Kuwabara Y, Ichiya Y, Otsuka M, Tahara T, Miyake Y, Mizuguchi M, Gunasekera R, Masuda K (1989) Evaluation of the significance of “redistribution” in I-123 IMP SPECT in cerebrovascular disorders — a comparative study with PET. Eur J Nucl Med 15: 746–749

    PubMed  Google Scholar 

  20. Yamada S (1982) Arteriovenous malformations in the functional area: surgical treatment and regional cerebral blood flow. Neurol Res 4: 283–322

    PubMed  Google Scholar 

  21. Young WL, Prohovnik I, Ornstein E, Sisti MB, Solomon RA, Stein BM, Ostapkovich N (1988) Monitoring of intraoperative cerebral hemodynamics before and after arteriovenous malformation resection. Anesth Analg 67: 1011–1014

    PubMed  Google Scholar 

  22. Young WL, Solomon RA, Prohovnik I, Ornstein E, Weinstein J, Stein BM (1988)133Xe blood flow monitoring during arteriovenous malformation resection: a case of intraoperative hyperperfusion with subsequent brain swelling. Neurosurgery 22: 765–769

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Takeuchi, S., Abe, H., Nishimaki, K. et al. Cerebral haemodynamic changes after endovascular treatment of arteriovenous malformations: Evaluation by single-photon emission CT. Acta neurochir 127, 142–150 (1994). https://doi.org/10.1007/BF01808757

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01808757

Keywords

Navigation