Skip to main content
Log in

Recherche d'une tres grande vitesse d'analyse par chromatographie en phase gazeuse. II. Description d'un appareil automatique

A study in high-speed gas chromatography. II. Description of automatic equipment

  • Originals
  • Published:
Chromatographia Aims and scope Submit manuscript

Summary

A computer-controlled automatic gas chromatograph is described. It uses a fluidic logic gate as a sampling device. The sample is introduced as a narrow band, a few milli-seconds wide. Short open tubular columns (L<1 m), with narrow internal diameter (dc<100 μm) can be used to achieve difficult separations (N>104) in a few seconds. This equipment can be used for physico-chemical measurements as well as in process control.

Résumé

On décrit un appareil de chromatographie en phase gazeuse commandé par un ordinateur et muni d'un dispositif d'injection utilisant un circuit logique fluidique. L'échantillon est introduit sous forme d'une bande ayant quelques millisecondes de largeur. On peut donc utiliser des colonnes capillaires courtes (L<1 m) et de faible diamètre (dc<100 μm) et obtenir des séparations difficiles (N>104) en quelques secondes. Cet appareil peut servir à des mesures physico-chimiques et en contrôle industriel.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Références

  1. D. H. Desty, A. Goldup, Gas Chromatography 1960,R. P. W. Scott, Ed., Londres, 1960, p. 162.

  2. D. H. Desty, A. Goldup, W. T. Swanton, Gas Chromatography,N. Brenner, J. E. Callen, M. D. Weiss, Eds., Academic Press, New York, 1962, p. 105.

    Google Scholar 

  3. M. Cheneau, F. Farre-Rius, G. Guiochon, L. Jacque, C. Landault, J. Merle D'Aubigne, Bull. Soc. Chim. France. 3416, 1965.

  4. R. L. Wade, S. P. Cram, Anal. Chem.44, 131 (1972).

    Google Scholar 

  5. G. Gaspar, P. Arpino, G. Guiochon, J. Chromatog. Sci.15, 256 (1977).

    CAS  Google Scholar 

  6. G. Gaspar, R. Annino, C. Vidal-Madjar, G. Guiochon, à paraître.

  7. G. Schomburg, R. Dielmann, H. Husmann, F. Weeke, J. Chromatog.122, 55 (1976).

    CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Gaspar, G., Olivo, J. & Guiochon, G. Recherche d'une tres grande vitesse d'analyse par chromatographie en phase gazeuse. II. Description d'un appareil automatique. Chromatographia 11, 321–327 (1978). https://doi.org/10.1007/BF02314769

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02314769