Estimate of the absorbed dose due to 20Ne beam and its fragments produced in interactions with tissue-equivalent materials

https://doi.org/10.1016/0969-8078(93)90196-BGet rights and content

Abstract

CR-39 and CN-85 plastic detectors were used for estimating the absorbed dose due to both 77.1 MeV·nucl-120Ne GANIL beam and its fragments, with charge of 3 < ZF < 9, formed in interactions of primeries with water and plexiglas. Preliminary results on the depth dose distributions are presented in this report.

References (2)

  • A. Golovchenko et al.

    CR-39 charge resolution and relative yields of nuclear fragments produced in interactions of 77.1 MeV /nucleon Ne beam with water

    (1992)
  • S.P. Tretyakova et al.

    The use of CR-39 plastic detector for the detection and identification of ions with 2 < Z < 5

    Nucl. Instr. Meth.

    (1984)

Cited by (2)

  • Characterization of a 292 MeV/n <sup>19</sup>F beam after passage through a thick plexiglas target

    1996, Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms
View full text