Freon plasma surface treatment for multipactoring

https://doi.org/10.1016/0168-9002(93)90644-WGet rights and content

Abstract

Persistent multipactoring in lead-plated copper quarter-wave resonators (QWRs) can be eliminated by a few minutes exposure to ionized Freon-11 (CCl3F) at a pressure of 1 mTorr.

References (8)

  • I. Ben-Zvi et al.

    Nucl. Instr. and Meth.

    (1983)
  • J.W. Noé et al.

    Nucl. Instr. and Meth.

    (1990)
  • J.W. Noé et al.
  • M.D. Malev et al.

    Nucl. Instr. and Meth.

    (1986)
There are more references available in the full text version of this article.