A logarithmic detection system suitable for a 4π array

https://doi.org/10.1016/0168-9002(85)90472-3Get rights and content

Abstract

A low pressure multiwire proportional counter, a Bragg curve counter, and an array of CaF2/plastic scintillator telescopes have been developed in a geometry suitable for close packing into a 4π detector designed to study nucleus-nucleus reactions at 100–200 MeV/nucleon. The multiwire counter is hexagonal in shape and gives XY position information using resistive charge division from nichrome-coated stretched polypropylene foils. The Bragg curve counter is a hexagonal pyramid with the charge taken from a Frisch gridded anode. A field shaping grid gives the Bragg curve counter a radial field. The scintillator telescopes are shaped as truncated triangular pyramids such that when stacked together they form a truncated hexagonal pyramid. The light signal of the CaF2-plastic combination is read with one phototube using a phoswich technique to separate the ΔE signal from the E signal. The entire system has been tested so far for particles with 1 ≦ Z ≦ 18 and gives good position, charge, and time resolution.

References (26)

  • G.D. Westfall et al.

    Phys. Lett.

    (1982)
  • H.H. Gutbrod et al.

    Phys. Lett.

    (1983)
  • A. Baden et al.

    Nucl. Instr. and Meth.

    (1982)
  • D. Fancher et al.

    Nucl. Instr. and Meth.

    (1979)
  • D.E. Greiner

    Nucl. Phys.

    (1983)
  • A. Breskin et al.

    Nucl. Instr. and Meth.

    (1979)
    A. Breskin et al.

    IEEE Trans. Nucl. Sci. NS-27

    (1980)
  • J. van der Plicht et al.

    Nucl. Instr. and Meth.

    (1983)
  • C.R. Gruhn et al.

    Nucl. Instr. and Meth.

    (1982)
  • Ch. Schiessl et al.

    Nucl. Instr. and Meth.

    (1982)
  • J.M. Asselineau et al.

    Nucl. Instr. and Meth.

    (1982)
  • R.J. McDonald et al.

    Nucl. Instr. and Meth.

    (1984)
  • A. Moroni et al.

    Nucl. Instr. and Meth.

    (1984)
  • L. Harwood, POISSON, private...
  • Cited by (101)

    • A gas detection system for fragment identification in low-energy heavy-ion collisions

      2018, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
    • Extension of energy acceptance of Bragg curve counter at the high-energy end

      2008, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
    • A Bragg curve counter with an active cathode to improve the energy threshold in fragment measurements

      2008, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
      Citation Excerpt :

      It can then determine the atomic number (Z) and energy (E) of fragments from the Bragg peak and integrated charge, respectively, with a large solid angle without using transmission detectors incurring an unwanted increase in threshold energy for the measurement. The BCC is widely used as a heavy ion detector in the fields of nuclear physics and material analysis [5–21]. The BCC offers advantages in comparison with the counters consisting of silicon detectors: large solid angle, low radiation damage, a relatively small pulse-height defect and low sensitivities to backgrounds of photon and neutrons.

    • Light charged particle and intermediate mass fragment cross-sections in GeV proton-induced reactions

      2006, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
    • PISA - An experiment for fragment spectroscopy at the Internal Beam of COSY: Application of an Axial Ionization Chamber

      2004, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
    View all citing articles on Scopus
    View full text