Conclusions
-
1.
It is suggested to extend the requirement of SNiP concerning the conduction of hydraulic tests of steel penstocks to penstocks embedded in rock or concrete.
-
2.
Embedded penstocks should be tested after concreting. It is necessary to examine the steel shell from the inside immediately after emptying.
-
3.
It is recommended to use a test pressure not less than the design pressure.
-
4.
It is necessary to find a grouting method that does not disturb the soundness of the penstock shell.
Similar content being viewed by others
Literature cited
A. M. Shor, “Full-scale strength tests of penstock outlets of the Nurek hydroelectric stations,” Gidrotekh. Stroit., No. 1 (1975).
Richtlinien für die Erstellung von stählernen Druckrohrlietungen für Wasserkraftanlager. Verlinigung Deutscher Elektrizitätswerke (VDEWeV). Ausgabe, Frankfurt am Main (1958).
H. Zuger, “Druckschactpanzerung und Verteilleitung des Kopswerks,” Österreichische Zeitschrift für Elektrizitätswirtschaft,23, No. 7 (1970).
Additional information
Translated from Gidrotekhnicheskoe Stroitel'stvo, No. 6, pp. 12–14, June, 1979.
Rights and permissions
About this article
Cite this article
Freishist, A.R., Chobanis, Y.G. & Shor, A.M. Hydraulic tests of pipes embedded in tunnels or concrete masses. Hydrotechnical Construction 13, 543–546 (1979). https://doi.org/10.1007/BF02305238