Abstract

This paper describes the performance of the Fully Depleted pn-junction CCD (pn-CCD) system, developed for ESA's XMM-satellite mission for soft x-ray imaging and spectroscopy in the single photon counting mode in the 100 eV to 10 keV photon range. The 58 mm x 60 mm large pn-CCD array, designed and fabricated at the Semiconductor Lab (Halbleiterlabor) of the Max-Planck-Institut, uses pn-junctions for registers and as backside structure. This concept naturally enables full depletion of the detector volume independent of the silicon wafer's resistivity and thickness, and as such make it an efficient detector for the x-ray region and the infrared. For high detection efficiency in the soft x-ray region and UV, an ultrathin pn-CCD backside deadlayer has been realized. Each pn-CCD-channel is equipped with its own on-chip JFET amplifier which, in combination with the CAMEX-amplifier and multiplexing chip, facilitates parallel readout and fast data rate: the cooled pn-CCD system can be read out at a data rate up to 3 MHz with an electronic noise floor of ENC < 5 e-.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. E. Gatti, P. Rehak, Nucl. Instrum. Methods, A225 (1984) 608

    Google Scholar 

  2. E. Gatti, P. Rehak, Nucl. Instrum. Methods, A226 (1984) 129

    Google Scholar 

  3. E. Pinotti et al., Nucl. Instrum. Methods, A326 (1993) 85

    Google Scholar 

  4. N. Meidinger et al., Nucl. Instrum. Methods, A377 (1996) 298

    Google Scholar 

  5. Report on ESA's Scientific Satellites, esa SP-1110, (1989) 85

  6. L. Strüder et al., Nucl. Instrum. Methods, A288 (1990) 227

    Google Scholar 

  7. W. Buttler et al., Nucl. Instrum. Methods, A279 (1989) 204

    Google Scholar 

  8. H. Bräuninger et al., Nucl. Instrum. Methods, A326 (1993) 129

    Google Scholar 

  9. H. Soltau et al., Nucl. Instr Methods, A377 (1996) 340

    Google Scholar 

  10. R. Hartmann et al., Nucl. Instrum. Methods, A377 (1996) 191

    Google Scholar 

  11. R. Hartmann et al, Nucl. Instrum. Methods, to be published

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

von Zanthier, C., Bräuninger, H., Dennerl, K. et al. A Fully Depleted pn-Junction CCD for Infrared-, UV- and X- ray detection. Experimental Astronomy 8, 89–96 (1998). https://doi.org/10.1023/A:1008008808704

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1008008808704

Keywords

Navigation